Gradient-echo 3D imaging of Rb polarization in fiber-coupled atomic magnetometer

被引:6
|
作者
Savukov, I. [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
Atomic magnetometer; MRI; Rb; 3D imaging; VAPOR; XE-129;
D O I
10.1016/j.jmr.2015.03.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analogy between atomic and nuclear spins is exploited to implement 3D imaging of polarization inside the cell of an atomic magnetometer. The resolution of 0.8 mm x 1.2 mm x 1.4 mm has been demonstrated with the gradient-echo imaging method. The imaging can be used in many applications. One such an application is the evaluation of active volume of an atomic magnetometer for sensitivity analysis and optimization. It has been found that imaging resolution is limited due to de-phasing from spin-exchange collisions and diffusion in the presence of gradients, and for a given magnetometer operational parameters, the imaging sequence has been optimized. Diffusion decay of the signal in the presence of gradients has been modeled numerically and analytically, and the analytical results, which agreed with numerical simulations, have been used to fit the spin-echo gradient measurements to extract the diffusion coefficient. The diffusion coefficient was found in agreement with previous measurements. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 50 条
  • [41] In-situ determination of spin polarization in a single-beam fiber-coupled spin-exchange-relaxation-free atomic magnetometer with differential detection
    Ma, Yintao
    Iao, Zhixia
    Chen, Yao
    Luo, Guoxi
    Yu, Mingzhi
    Wang, Yanbin
    Lu, Dejiang
    Zhao, Libo
    Yang, Ping
    Lin, Qijing
    Jiang, Zhuangde
    OPTICS EXPRESS, 2023, 31 (03) : 3743 - 3754
  • [42] 2D AND 3D HIGH-RESOLUTION GRADIENT-ECHO FUNCTIONAL IMAGING OF THE BRAIN - VENOUS CONTRIBUTIONS TO SIGNAL IN MOTOR CORTEX STUDIES
    HAACKE, EM
    HOPKINS, A
    LAI, S
    BUCKLEY, P
    FRIEDMAN, L
    MELTZER, H
    HEDERA, P
    FRIEDLAND, R
    KLEIN, S
    THOMPSON, L
    DETTERMAN, D
    TKACH, J
    LEWIN, JS
    NMR IN BIOMEDICINE, 1994, 7 (1-2) : 54 - 62
  • [43] Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    Li, DB
    Haacke, EM
    Tarr, RW
    Venkatesan, R
    Lin, WL
    Wielopolski, P
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 415 - 424
  • [44] Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation
    Wang, Haifeng
    Liang, Dong
    Su, Shi
    King, Kevin F.
    Chang, Yuchou
    Liu, Xin
    Zheng, Hairong
    Ying, Leslie
    MEDICAL PHYSICS, 2020, 47 (04) : 1579 - 1589
  • [45] Magnetic resonance imaging of pulmonary parenchymal disease using a modified breath-hold 3D gradient-echo technique: Initial observations
    Bader, TR
    Semelka, RC
    Pedro, MS
    Armao, DM
    Brown, MA
    Molina, PL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) : 31 - 38
  • [46] 3D magnetization prepared elliptical centric fast gradient echo Imaging
    Lin, Chen
    Bernstein, Matt A.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 434 - 439
  • [47] Identification of carotid lipid-rich necrotic core and calcification by 3D magnetization-prepared rapid acquisition gradient-echo imaging
    Qiao, Huiyu
    Li, Feiyu
    Xu, Dongxiang
    Liu, Gaifen
    Yuan, Chun
    Zhao, Xihai
    MAGNETIC RESONANCE IMAGING, 2018, 53 : 71 - 76
  • [48] MR imaging of coronary arteries: noncontrast free-breathing whole heart acquisition with ultrafast 3D balanced gradient-echo technique
    Auger, F.
    Willoteaux, S.
    Lions, C.
    Negaiwi, Z.
    Gengler, L.
    Midulla, M.
    Akkari, K.
    Beregi, J. P.
    JOURNAL DE RADIOLOGIE, 2010, 91 (01): : 78 - 81
  • [49] Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography
    Börnert, P
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Koken, P
    Spuentrup, E
    Manning, WJ
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 789 - 794
  • [50] Comparison of 3D Gradient-Echo Versus 2D Sequences for Assessing Shoulder Joint Image Quality in MRI
    Shirani, Shapoor
    Mousavi, Najmeh-Sadat
    Talib, Milad Ali
    Bagheri, Mohammad Ali
    Gharebagh, Elahe Jazayeri
    Hameed, Qasim Abdulsahib Jaafar
    Dehghani, Sadegh
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2024, 2024