Gradient-echo 3D imaging of Rb polarization in fiber-coupled atomic magnetometer

被引:6
|
作者
Savukov, I. [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
Atomic magnetometer; MRI; Rb; 3D imaging; VAPOR; XE-129;
D O I
10.1016/j.jmr.2015.03.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analogy between atomic and nuclear spins is exploited to implement 3D imaging of polarization inside the cell of an atomic magnetometer. The resolution of 0.8 mm x 1.2 mm x 1.4 mm has been demonstrated with the gradient-echo imaging method. The imaging can be used in many applications. One such an application is the evaluation of active volume of an atomic magnetometer for sensitivity analysis and optimization. It has been found that imaging resolution is limited due to de-phasing from spin-exchange collisions and diffusion in the presence of gradients, and for a given magnetometer operational parameters, the imaging sequence has been optimized. Diffusion decay of the signal in the presence of gradients has been modeled numerically and analytically, and the analytical results, which agreed with numerical simulations, have been used to fit the spin-echo gradient measurements to extract the diffusion coefficient. The diffusion coefficient was found in agreement with previous measurements. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 50 条
  • [21] Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
    Kim, Young Jin
    Savukov, Igor
    Newman, Shaun
    APPLIED PHYSICS LETTERS, 2019, 114 (14)
  • [22] Accelerated acquisition of carotid MR angiography using 3D gradient-echo imaging with two-point Dixon
    Irie, Ryusuke
    Amemiya, Shiori
    Ueyama, Tsuyoshi
    Suzuki, Yuichi
    Kamiya, Kouhei
    Takao, Hidemasa
    Mori, Harushi
    Abe, Osamu
    NEURORADIOLOGY, 2020, 62 (10) : 1345 - 1349
  • [23] Accelerated acquisition of carotid MR angiography using 3D gradient-echo imaging with two-point Dixon
    Ryusuke Irie
    Shiori Amemiya
    Tsuyoshi Ueyama
    Yuichi Suzuki
    Kouhei Kamiya
    Hidemasa Takao
    Harushi Mori
    Osamu Abe
    Neuroradiology, 2020, 62 : 1345 - 1349
  • [24] High-sensitivity pump-probe atomic magnetometer based on single fiber-coupled
    Zhao, Binbin
    Tang, Junjian
    Yang, Hongying
    Li, Lin
    Zhang, Yaohua
    Liu, Ying
    Zhai, Yueyang
    OPTICS AND LASER TECHNOLOGY, 2023, 159
  • [25] MR-IMAGING OF THE NORMAL MENINGES - COMPARISON OF CONTRAST-ENHANCEMENT PATTERNS ON 3D GRADIENT-ECHO AND SPIN-ECHO IMAGES
    FARN, JW
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 131 - 135
  • [26] SIMULATION OF SUSCEPTIBILITY ARTIFACTS IN 2D AND 3D FOURIER-TRANSFORM SPIN-ECHO AND GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING
    BAKKER, CJG
    BHAGWANDIEN, R
    MOERLAND, MA
    RAMOS, LMP
    MAGNETIC RESONANCE IMAGING, 1994, 12 (05) : 767 - 774
  • [27] Short echo-time 3D radial gradient-echo MRI using concurrent dephasing and excitation
    Park, Jang-Yeon
    Moeller, Steen
    Goerke, Ute
    Auerbach, Edward
    Chamberlain, Ryan
    Ellermann, Jutta
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 428 - 436
  • [28] Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T
    Ozturk, Arzu
    Aygun, Nafi
    Smith, Seth A.
    Caffo, Brian
    Calabresi, Peter A.
    Reich, Daniel S.
    NEURORADIOLOGY, 2013, 55 (04) : 431 - 439
  • [29] Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T
    Arzu Ozturk
    Nafi Aygun
    Seth A. Smith
    Brian Caffo
    Peter A. Calabresi
    Daniel S. Reich
    Neuroradiology, 2013, 55 : 431 - 439
  • [30] Suspected pancreatic cancer: Evaluation by dynamic gadolinium-enhanced 3D gradient-echo
    Birchard, KR
    Semelka, RC
    Hyslop, WB
    Brown, A
    Armao, D
    Firat, Z
    Vaidean, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (03) : 700 - 703