Glassy carbon electrodes modified with multiwalled carbon nanotubes for the determination of ascorbic acid by square-wave voltammetry

被引:24
|
作者
Kumar, Sushil [2 ]
Vicente-Beckett, Victoria [1 ]
机构
[1] Cent Queensland Univ, Ctr Environm Management, Rockhampton, Qld 4702, Australia
[2] Cent Queensland Univ, Ctr Plant & Water Sci, Rockhampton, Qld 4702, Australia
来源
关键词
ascorbic acid; carbon nanotubes; glassy carbon electrode; square-wave voltammetry; SELECTIVE DETERMINATION; FRUIT JUICES; VITAMIN-C; DOPAMINE; PERFORMANCE; NAFION;
D O I
10.3762/bjnano.3.45
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Multiwalled carbon nanotubes were used to modify the surface of a glassy carbon electrode to enhance its electroactivity. Nafion served to immobilise the carbon nanotubes on the electrode surface. The modified electrode was used to develop an analytical method for the analysis of ascorbic acid (AA) by square-wave voltammetry (SWV). The oxidation of ascorbic acid at the modified glassy carbon electrode showed a peak potential at 315 mV, about 80 mV lower than that observed at the bare (unmodified) electrode. The peak current was about threefold higher than the response at the bare electrode. Replicate measurements of peak currents showed good precision (3% rsd). Peak currents increased with increasing ascorbic acid concentration (dynamic range = 0.0047-5.0 mmol/L) and displayed good linearity (R-2 = 0.994). The limit of detection was 1.4 mu mol/L AA, while the limit of quantitation was 4.7 mu mol/L AA. The modified electrode was applied to the determination of the amount of ascorbic acid in four brands of commercial orange-juice products. The measured content agreed well (96-104%) with the product label claim for all brands tested. Recovery tests on spiked samples of orange juice showed good recovery (99-104%). The reliability of the SWV method was validated by conducting parallel experiments based on high-performance liquid chromatography (HPLC) with absorbance detection. The observed mean AA contents of the commercial orange juice samples obtained by the two methods were compared statistically and were found to have no significant difference (P = 0.05).
引用
收藏
页码:388 / 396
页数:9
相关论文
共 50 条
  • [21] Multiwall Carbon Nanotubes-modified Glassy Carbon Electrode for Square-wave Stripping Voltammetric Determination of Aqueous Antimony (III) ion
    Guo, Yaoguang
    Yan, Wei
    Lou, Xiaoyi
    Xiao, Dongxue
    Zhai, Ping
    Zhao, Guangchao
    Zhang, Wugang
    Huang, Peng
    Wang, Zhaohui
    Liu, Jianshe
    [J]. ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 1571 - +
  • [22] Square-wave voltammetric determination of ascorbic acid based on its electrocatalytic oxidation at zeolite-modified carbon-paste electrodes
    Nezamzadeh, Alireza
    Amini, Mohammad K.
    Faghihian, Hossein
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (08): : 583 - 594
  • [23] Highly Selective Determination of Dopamine in the Presence of Ascorbic Acid and Serotonin at Glassy Carbon Electrodes Modified with Carbon Nanotubes Dispersed in Polyethylenimine
    Rodriguez, Marcela C.
    Rubianes, Maria D.
    Rivas, Gustavo A.
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (11) : 6003 - 6009
  • [24] Poly(pyridine-3-boronic acid)/Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrodes for Simultaneous Determination of Ascorbic Acid, 3,4-Dihydroxyphenylacetic Acid and Uric Acid
    Wu, Zhijiao
    Zhao, Hong
    Xue, Ying
    He, Yujian
    Li, Xiangjun
    Yuan, Zhuobin
    [J]. ELECTROANALYSIS, 2010, 22 (19) : 2196 - 2201
  • [25] SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF PARACETAMOL AND ASCORBIC ACID USING ACTIVATED GLASSY CARBON ELECTRODE: CYCLIC VOLTAMMETRY AND SQUARE WAVE VOLTAMMETRY STUDY
    Shewarega, Yared
    Yenealem, Dereje
    Siyum, Fikadu
    [J]. ACTA CHEMICA IASI, 2021, 29 (02) : 107 - 122
  • [26] DETERMINATION OF EPINEPHRINE IN CARP BRAIN CELLS BY SQUARE-WAVE ANODIC STRIPPING VOLTAMMETRY WITH CARBON NANOTUBES
    Ly, Suw Young
    [J]. ANALYTICAL LETTERS, 2012, 45 (10) : 1197 - 1203
  • [27] Determination of butylparaben by adsorptive stripping voltammetry at glassy carbon electrodes modified with multi-wall carbon nanotubes
    Angeles Lorenzo, Maria
    Sanchez Arribas, Alberto
    Moreno, Monica
    Bermejo, Esperanza
    Chicharro, Manuel
    Zapardiel, Antonio
    [J]. MICROCHEMICAL JOURNAL, 2013, 110 : 510 - 516
  • [28] Determination of levofloxacin in human urine by adsorptive square-wave anodic stripping voltammetry on a glassy carbon electrode
    Radi, A
    El-Sherif, Z
    [J]. TALANTA, 2002, 58 (02) : 319 - 324
  • [29] Quantification of Quercetin Using Glassy Carbon Electrodes Modified with Multiwalled Carbon Nanotubes Dispersed in Polyethylenimine and Polyacrylic Acid
    Gutierrez, Fabiana
    Ortega, Gabriela
    Luis Cabrera, Jose
    Rubianes, Maria D.
    Rivas, Gustavo A.
    [J]. ELECTROANALYSIS, 2010, 22 (22) : 2650 - 2657
  • [30] Square wave anodic stripping voltammetric determination of lead(II) using a glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes
    He, Xiuhui
    Chen, Li
    Xie, Xuan
    Su, Zhaohong
    Qin, Cong
    Liu, Ying
    Ma, Ming
    Yao, Shouzhuo
    Deng, Le
    Xie, Qingji
    Tian, Yun
    Qin, Dilan
    Luo, Yueping
    [J]. MICROCHIMICA ACTA, 2012, 176 (1-2) : 81 - 89