Determination of levofloxacin in human urine by adsorptive square-wave anodic stripping voltammetry on a glassy carbon electrode

被引:94
|
作者
Radi, A [1 ]
El-Sherif, Z
机构
[1] Mansoura Univ, Fac Sci, Dept Chem, Dumyat 34517, Egypt
[2] Natl Org Drug Control & Res, Cairo, Egypt
关键词
levofloxacin; glassy carbon electrode; stripping voltammetry; urine analysis;
D O I
10.1016/S0039-9140(02)00245-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The adsorption behavior of levofloxacin on a glassy carbon electrode was explored by cyclic and square-wave voltammetry. The drug was accumulated on a glassy carbon electrode and a well-defined oxidation peak was obtained in acetate buffer pH 5.0. Using square-wave anodic stripping voltammetry and accumulation at +0.4 V versus Ag/AgCl (saturated KCl) for 300 s, linear calibration graph was obtained from 6.0 x 10(-9) to 5.0 x 10(-7) M levofloxacin. The detection limit was calculated to be 5.0 x 10(-9) M. The R.S.D. determined from ten determinations at the 1.0 x 10(-7) M level was 1.7%. The method was applied for the direct determination of levofloxacin in diluted urine samples. It was validated using high-performance liquid chromatography (HPLC) as a reference method. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:319 / 324
页数:6