Determination of Norfloxacin by square-wave adsorptive voltammetry on a glassy carbon electrode

被引:76
|
作者
Ghoneim, MM [1 ]
Radi, A
Beltagi, AM
机构
[1] Tanta Univ, Fac Sci, Dept Chem, Tanta 31527, Egypt
[2] Tanta Univ, Fac Educ, Kafr El Sheikh 33516, Egypt
[3] Mansoura Univ, Fac Sci, Dept Chem, Dumyat 34517, Egypt
关键词
norfloxacin; glassy carbon electrodes; stripping voltammetry; urine analysis;
D O I
10.1016/S0731-7085(00)00475-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The adsorptive and electrochemical behavior of norfloxacin on a glassy carbon electrode were investigated by cyclic and square-wave voltammetry. Cyclic voltammetric studies indicated that the process was irreversible and fundamentally controlled by adsorption. To obtain a good sensitivity. the solution conditions and instrumental parameters were studied using square-wave voltammetry. In acetate buffer of pH 5.0. nurfloxacin gave a sensitive adsorptive oxidative peak at 0.920 V (versus Ag-AgCl). Applicability to measurement of norfloxacin at submicromolar levels in urine samples was illustrated. The peak current was linear with the norfloxacin concentration in the range 5-50 mug mi urine. The detection limit was 1.1 mug ml(-1) urine. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [1] Determination of trimetazidine HCl by adsorptive stripping square-wave voltammetry at a glassy carbon electrode
    Ghoneim, MM
    Khashaba, PY
    Beltagi, AM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (1-2) : 235 - 241
  • [2] Determination of levofloxacin in human urine by adsorptive square-wave anodic stripping voltammetry on a glassy carbon electrode
    Radi, A
    El-Sherif, Z
    TALANTA, 2002, 58 (02) : 319 - 324
  • [3] Determination of Allura Red in the Presence of Cetylpyridinium Bromide by Square-wave Adsorptive Stripping Voltammetry on a Glassy Carbon Electrode
    Nagles, Edgar
    Garcia-Beltran, Olimpo
    ANALYTICAL SCIENCES, 2018, 34 (10) : 1171 - 1175
  • [4] Determination of Allura Red in the Presence of Cetylpyridinium Bromide by Square-wave Adsorptive Stripping Voltammetry on a Glassy Carbon Electrode
    Edgar Nagles
    Olimpo García-Beltrán
    Analytical Sciences, 2018, 34 : 1171 - 1175
  • [5] Determination of amlodipine besylate by adsorptive square-wave anodic stripping voltammetry on glassy carbon electrode in tablets and biological fluids
    Gazy, AAK
    TALANTA, 2004, 62 (03) : 575 - 582
  • [6] Square-wave and cyclic voltammetry of epicatechin gallate on glassy carbon electrode
    Novak, Ivana
    Seruga, Marijan
    Komorsky-Lovric, Sebojka
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 631 (1-2) : 71 - 75
  • [7] Square-wave adsorptive stripping voltammetry at glassy carbon electrode for selective determination of manganese. Application to some industrial samples
    El-Maali, NA
    El-Hady, DA
    ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) : 239 - 249
  • [8] Simultaneous Determination of Lipophilic Vitamin Esters Using Square-Wave Voltammetry at the Glassy Carbon Electrode
    Jashari, Granit
    Musliu, Arber
    Sys, Milan
    Arbneshi, Tahir
    Mikysek, Tomas
    Svancara, Ivan
    Metelka, Radovan
    ELECTROANALYSIS, 2021, 33 (02) : 537 - 542
  • [9] Simultaneous Determination of Vitamin E and Vitamin K in Food Supplements Using Adsorptive Stripping Square-Wave Voltammetry at Glassy Carbon Electrode
    Kastrati, Gylxhane
    Jashari, Granit
    Sys, Milan
    Svecova, Blanka
    Arbneshi, Tahir
    Metelka, Radovan
    Bilkova, Zuzana
    Korecka, Lucie
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [10] DETERMINATION OF TETRAMETHRIN BY ADSORPTIVE STRIPPING WITH SQUARE-WAVE VOLTAMMETRY
    HERNANDEZ, P
    GALANESTELLA, F
    HERNANDEZ, L
    ELECTROANALYSIS, 1992, 4 (01) : 45 - 49