Determination of Norfloxacin by square-wave adsorptive voltammetry on a glassy carbon electrode

被引:76
|
作者
Ghoneim, MM [1 ]
Radi, A
Beltagi, AM
机构
[1] Tanta Univ, Fac Sci, Dept Chem, Tanta 31527, Egypt
[2] Tanta Univ, Fac Educ, Kafr El Sheikh 33516, Egypt
[3] Mansoura Univ, Fac Sci, Dept Chem, Dumyat 34517, Egypt
关键词
norfloxacin; glassy carbon electrodes; stripping voltammetry; urine analysis;
D O I
10.1016/S0731-7085(00)00475-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The adsorptive and electrochemical behavior of norfloxacin on a glassy carbon electrode were investigated by cyclic and square-wave voltammetry. Cyclic voltammetric studies indicated that the process was irreversible and fundamentally controlled by adsorption. To obtain a good sensitivity. the solution conditions and instrumental parameters were studied using square-wave voltammetry. In acetate buffer of pH 5.0. nurfloxacin gave a sensitive adsorptive oxidative peak at 0.920 V (versus Ag-AgCl). Applicability to measurement of norfloxacin at submicromolar levels in urine samples was illustrated. The peak current was linear with the norfloxacin concentration in the range 5-50 mug mi urine. The detection limit was 1.1 mug ml(-1) urine. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [31] Determination of Trace Chromium by Square-Wave Adsorptive Cathodic Stripping Voltammetry at an Improved Bismuth Film Electrode
    Zhang, Qing
    Zhong, Shang-wei
    Su, Jia-li
    Li, Xiang-jun
    Zou, Hong
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : H237 - H242
  • [32] Glassy carbon electrodes modified with multiwalled carbon nanotubes for the determination of ascorbic acid by square-wave voltammetry
    Kumar, Sushil
    Vicente-Beckett, Victoria
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2012, 3 : 388 - 396
  • [33] Electro-Oxidation and Determination of Benomyl by Square-Wave Adsorptive Stripping Voltammetry
    Sarigul, Tuba
    Inam, Recai
    Demir, Ersin
    Aboul-Enein, Hassan Y.
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 995 - 1000
  • [34] ADSORPTIVE STRIPPING VOLTAMMETRY OF RIBOFLAVIN BY SQUARE-WAVE POLAROGRAPHY
    SAWAMOTO, H
    KATSURAGI, H
    NIPPON KAGAKU KAISHI, 1989, (02) : 299 - 301
  • [35] DETERMINATION OF VITAMIN-K1 BY ADSORPTIVE STRIPPING SQUARE-WAVE VOLTAMMETRY
    VIRE, JC
    LOPEZ, V
    PATRIARCHE, GJ
    CHRISTIAN, GD
    ANALYTICAL LETTERS, 1988, 21 (12) : 2217 - 2225
  • [36] Square-wave adsorptive stripping voltammetry for the determination of cyclofenil after photochemical derivatization
    Pacheco, WR
    Farias, PAM
    Aucelio, RQ
    ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) : 67 - 73
  • [37] Electrochemical determination of closantel in the commercial formulation by square-wave adsorptive stripping voltammetry
    Mariola Brycht
    Agnieszka Nosal-Wiercińska
    Karolina Sipa
    Konrad Rudnicki
    Sławomira Skrzypek
    Monatshefte für Chemie - Chemical Monthly, 2017, 148 : 463 - 472
  • [39] SQUARE-WAVE CATHODIC ADSORPTIVE STRIPPING VOLTAMMETRY OF RISPERIDONE
    Tasdemir, Ibrahim Hudai
    Cakirer, Orhan
    Erk, Nevin
    Kilic, Esma
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (03) : 159 - 176
  • [40] Electrochemical determination of closantel in the commercial formulation by square-wave adsorptive stripping voltammetry
    Brycht, Mariola
    Nosal-Wiercinska, Agnieszka
    Sipa, Karolina
    Rudnicki, Konrad
    Skrzypek, Slawomira
    MONATSHEFTE FUR CHEMIE, 2017, 148 (03): : 463 - 472