Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting

被引:19
|
作者
Suero, Eduardo M. [1 ]
Lueke, Ulrich [1 ]
Stuebig, Timo [1 ]
Hawi, Nael [1 ]
Krettek, Christian [1 ]
Liodakis, Emmanouil [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Knee; Total knee Arthroplasty; Patient-specific TKA; Computer navigation; Low-volume; Alignment; SURGEON PROCEDURE VOLUME; SHORT-TERM OUTCOMES; IMPROVED ACCURACY; CUTTING GUIDES; TKA; REPLACEMENT; ASSOCIATION; DIFFERENCE; BENEFIT; BLOCKS;
D O I
10.1016/j.otsr.2018.04.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Procedure volume is an important determinant of total knee arthroplasty (TKA) outcomes. We aimed to determine whether computer navigation or patient-specific instrumentation (PSI) would improve postoperative alignment in a low-volume setting. Hypothesis: PSI for TKA achieves better limb and implant alignment compared to conventional TKA and to computer navigated TKA. Materials and methods: This is a retrospective cohort study of 385 primary TI(As (Women = 59%. Mean age = 67 years. Mean BMI =30.1 kg/m(2)), which were performed using conventional instrumentation (n= 117; 30%), computer navigation (n= 209; 54%), or patient-specific instrumentation (n= 59; 15%) in a low-volume center (< 50 TKAs/year). The risk of postoperative leg and implant mechanical alignment outliers in the coronal plane (>3 degrees from neutral), average alignment and operation time were assessed. Results: The risk of postoperative mechanical alignment outliers (>3 degrees) was reduced by 89% in the navigated group (4% outliers) compared to the conventional group (35%) (RR = 0.11; p < 0.0001). No significant improvement was observed in the PSI group (27%) (RR = 0.91; p = 0.772). The risk of postoperative femoral component coronal alignment outliers was reduced by 63% in the navigated group (11%) compared to the conventional group (31%) (RR= 0.37; p = 0.018). No significant reduction in outliers was observed in the PSI group (32%) (RR= 1.08; p = 0.816). There was a reduction in the risk of tibial component coronal malalignment of 66% in the navigated group (5%) compared to the conventional group (13%) (RR= 0.33; p = 0.070). There was a two-fold increase in the risk of tibial component alignment outliers in the PSI group (29%) (RR= 1.94; p = 0.110). Discussion: Computer navigation improved postoperative alignment in TKA. No evidence of improved alignment was seen with patient-specific instrumentation. The routine use of patient-specific instrumentation in low-volume centers is not supported by the currently available data. Type of study: Retrospective cohort study. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:971 / 975
页数:5
相关论文
共 50 条
  • [31] A comparison of patient-specific and conventional instrumentation for total knee arthroplasty A MULTICENTRE RANDOMISED CONTROLLED TRIAL
    Abane, L.
    Anract, P.
    Boisgard, S.
    Descamps, S.
    Courpied, J. P.
    Hamadouche, M.
    BONE & JOINT JOURNAL, 2015, 97B (01): : 56 - 63
  • [32] Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial
    Chun Hoi Yan
    Kwong Yuen Chiu
    Fu Yuen Ng
    Ping Keung Chan
    Christian Xinshuo Fang
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3637 - 3645
  • [33] Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial
    Yan, Chun Hoi
    Chiu, Kwong Yuen
    Ng, Fu Yuen
    Chan, Ping Keung
    Fang, Christian Xinshuo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3637 - 3645
  • [34] A comparison of conventional and patient-specific instruments in total knee arthroplasty
    Kiriakos Daniilidis
    Carsten O. Tibesku
    International Orthopaedics, 2014, 38 : 503 - 508
  • [35] A comparison of conventional and patient-specific instruments in total knee arthroplasty
    Daniilidis, Kiriakos
    Tibesku, Carsten O.
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (03) : 503 - 508
  • [36] Patient-specific instrumentation in total knee arthroplasty: a review of the current literature
    Schoenthaler, Wolfgang
    Dauwe, Jan
    Holzer, Lukas A.
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (02): : 299 - 306
  • [37] Patient-Specific Instrumentation Does Not Improve Accuracy in Total Knee Arthroplasty
    Shen, Chong
    Tang, Zhi-Hong
    Hu, Jun-Zu
    Zou, Guo-Yao
    Xiao, Rong-Chi
    Yan, Dong-Xue
    ORTHOPEDICS, 2015, 38 (03) : E178 - E188
  • [38] Accuracy of a patient-specific instrumentation for coronal plane alignment of an anatomic alignment total knee arthroplasty system: A radiographic study
    Mueller, Konstantin
    Lerch, Solveig
    Sauer, Bernd
    Lerch, Matthias
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (06) : 1397 - 1406
  • [39] Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
    Mehdipour, Soheil
    Qoreishi, Mohamad
    Keipourfard, Ali
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2020, 8 (05): : 625 - 632
  • [40] Patient-Specific Versus Conventional Instrumentation for Total Knee Arthroplasty: Peri-Operative and Cost Differences
    DeHaan, Alexander M.
    Adams, Jacob R.
    DeHart, Matthew L.
    Huff, Thomas W.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11): : 2065 - 2069