ROBUST BEAT-TO-BEAT DETECTION ALGORITHM FOR PULSE RATE VARIABILITY ANALYSIS FROM WRIST PHOTOPLETHYSMOGRAPHY SIGNALS

被引:0
|
作者
Foroozan, Foroohar [1 ]
Mohan, Madhan [2 ]
Wu, Jian Shu [1 ]
机构
[1] Analog Devices Inc, Toronto, ON, Canada
[2] Jasmin Infotech, Madras, Tamil Nadu, India
关键词
Heart Rate Variability; Photoplethysmography (PPG); Pulse Rate Variability (PRV); Beat-to-Beat; Delineation; HEART-RATE-VARIABILITY;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Heart rate variability (HRV) from electrocardiograms (ECG) is a well-known diagnostic method for the assessment of autonomic nervous function of the heart. A more convenient approach to assess cardiac function is by using Photoplethysmography (PPG) waveforms where pulse rate variability (PRV) replaces HRV. However, the unavailability of robust detection algorithms for PPG signals has prevented the medical market from providing clinical diagnosis using PRV and from measuring biological information for wellness purposes, such as sleep stage, stress state, and fatigue. This paper provides a robust peak and onset detection algorithm for beat-to-beat (B2B) pulse interval analysis using PPG signals. We demonstrate our method through large data collection with the Analog Devices (ADI) multi-sensory watch platform with high coverage, sensitivity, and low Root Mean Square of Successive Difference (RMSSD) as compared to the B2B results from ECG signals.
引用
收藏
页码:2136 / 2140
页数:5
相关论文
共 50 条
  • [41] Quantitative beat-to-beat analysis of heart rate dynamics during exercise
    Tulppo, MP
    Makikallio, TH
    Takala, TES
    Seppanen, T
    Huikuri, HV
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 271 (01): : H244 - H252
  • [42] Beat-to-beat Heart Rate detection by Smartphone's Accelerometers: validation with ECG
    Landreani, F.
    Martin-Yebra, A.
    Casellato, C.
    Frigo, C.
    Pavan, E.
    Migeotte, P-F
    Caiani, E. G.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 525 - 528
  • [43] SIGNIFICANT OCCULT HYPOXEMIA WITH BRIEF INFANT APNEA - DETECTION BY BEAT-TO-BEAT PULSE OXIMETRY
    SPITZER, AR
    FOX, WW
    [J]. PEDIATRIC RESEARCH, 1986, 20 (04) : A441 - A441
  • [44] BEAT-TO-BEAT DETECTION OF HIS-PURKINJE SYSTEM SIGNALS USING ADAPTIVE FILTERS
    ALNASHASH, HAM
    KELLY, SW
    TAYLOR, DJE
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (02) : 117 - 125
  • [45] The acute effects of inhaled salbutamol on the beat-to-beat variability of heart rate and blood pressure assessed by spectral analysis
    Jartti, T
    Kaila, T
    Tahvanainen, K
    Kuusela, T
    Vanto, T
    Valimaki, I
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1997, 43 (04) : 421 - 428
  • [46] Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach
    Antink, Christoph Hoog
    Brueser, Christoph
    Leonhardt, Steffen
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1679 - 1690
  • [47] Robust Beat-to-Beat Interval from Wearable PPG using RLS and SSA
    Bhattacharjee, Tanuka
    Choudhury, Anirban Dutta
    Pal, Arpan
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4946 - 4952
  • [48] Beat-to-beat and spectral analyses of the noninvasive radial pulse and laser-Doppler signals in patients with hypertension
    Liu, Ju-Chi
    Hsu, Yi-Ping
    Zhu, Jia-Cheng
    Hao, Wen-Rui
    Yang, Tsung-Yeh
    Sung, Li-Chun
    Kao, Pai-Feng
    Hwang, Jaulang
    Hsiu, Hsin
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 79 (03) : 365 - 379
  • [49] Assessment of heart rate agreement on continuous photoplethysmography monitoring using a smartwatch versus beat-to-beat synchronized ECG monitoring
    Gruwez, H.
    Evens, S.
    Desteghe, L.
    Dreesen, P.
    Knaepen, L.
    Wouters, F.
    Dauw, J.
    Deferm, S.
    Smeets, C.
    Pison, L.
    Haemers, P.
    Heidbuchel, H.
    Vandervoort, P.
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 : 319 - 319
  • [50] A NEW MODALITY IN NONSTRESS TESTING - EVALUATION OF BEAT-TO-BEAT FETAL HEART-RATE-VARIABILITY
    LAUERSEN, NH
    WILSON, KH
    BILEK, A
    RAO, VSJ
    KURKULOS, M