Ambulatory Photoplethysmogram (PPG) is a more user-friendly choice for continuous cardiac monitoring as compared to Electrocardiogram (ECG). However, wearable PPG is often prone to motion artefacts. In this paper, we propose a novel pipeline for motion-resistant beat-to -beat interval extracHon from noisy PPG. Firstly, the effects of motion artefacts are minimized by using Adaptive Recursive-Least-Square (RLS) Filtering and Singular Spectrum Analysis (SSA). Next, the signal peaks are identified and their locations are corrected by weighted local interpolation. Finally, outlier peak-to-peak intervals are marked as incorrigible. Experimental validation on the training dataset of IEEE Signal Processing Cup 2015 reveals that the proposed method achieves 148% mean peak detection error rate and 1132 milliseconds mean absolute error of detected beat-to-beat intervals. The metric values outperform those obtained by the state-of-the-art techniques by at least 12.58 and 5.74 times respectively.
引用
收藏
页码:4946 / 4952
页数:7
相关论文
共 50 条
  • [1] Ear and Finger PPG Wearables for Night and Day Beat-to-Beat Interval Detection
    Haddad, Serj
    Boukhayma, Assim
    Caizzone, Antonino
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1686 - 1689
  • [2] BEAT-TO-BEAT INTERVAL MEASUREMENT IN THE ELECTROCARDIOGRAM
    KOELEMAN, ASM
    ROS, HH
    VANDENAKKER, TJ
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (03) : 213 - 219
  • [3] A BEAT-TO-BEAT INTERVAL GENERATOR FOR OPTOKINETIC NYSTAGMUS
    BALABAN, CD
    ARIEL, M
    [J]. BIOLOGICAL CYBERNETICS, 1992, 66 (03) : 203 - 216
  • [4] Estimation of Beat-to-Beat Interval from Wearable Photoplethysmography Sensor on Different Measurement Sites During Daily Activities
    Akbulut, Fatma Patlar
    Lawless, Kevin
    Tanneeru, Akhilesh
    Rao, Smriti
    Lee, Bongmook
    Misra, Veena
    [J]. 2018 IEEE SENSORS, 2018, : 657 - 660
  • [5] Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach
    Antink, Christoph Hoog
    Brueser, Christoph
    Leonhardt, Steffen
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1679 - 1690
  • [6] QUANTIFICATION OF FETAL HEART BEAT-TO-BEAT INTERVAL DIFFERENCES
    YEH, SY
    FORSYTHE, A
    HON, EH
    [J]. OBSTETRICS AND GYNECOLOGY, 1973, 41 (03): : 355 - 363
  • [7] Beat-to-beat validation of PPG as a tool to detect regular and irregular heartbeats
    Vandenberk, T.
    Pelckmans, C.
    Van Schelvergem, G.
    Van der Auwera, J.
    Thijs, I.
    Storms, V.
    Vandervoort, P.
    Grieten, L.
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 : 60 - 60
  • [8] Beat-to-beat QT interval variability in coronary patients
    Vrtovec, B
    Starc, V
    Starc, R
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (02) : 119 - 125
  • [9] Beat-to-Beat Variability of the QT Interval: A Systematic Review
    Niemeijer, Maartje N.
    van den Berg, Marten E.
    Eijgelsheim, Mark
    Kors, Jan A.
    Stricker, Bruno H.
    Rijnbeek, Peter
    [J]. PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2013, 22 : 329 - 329
  • [10] Beat-to-beat adaptation of QT interval to heart rate
    Pueyo, Esther
    Malik, Marek
    Laguna, Pablo
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2475 - 2478