Assessment of a Novel 3T MRI Compatible Cochlear Implant Magnet: Torque, Forces, Demagnetization, and Imaging

被引:16
|
作者
Tysome, James Russell [1 ]
Tam, Yu Chuen [2 ]
Patterson, Ilse [3 ]
Graves, Martin John [1 ]
Gazibegovic, Dzemal [4 ]
机构
[1] Cambridge Univ Hosp, Cambridge Biomed Campus,Hills Rd, Cambridge, England
[2] Emmeline Ctr, Hills Rd, Cambridge, England
[3] Radiol Dept, Hills Rd, Cambridge, England
[4] AB GmbH, ERC, Hannover, Germany
关键词
Cochlear implant; Imaging; Magnet; Magnetic resonance imaging; Torque; Ultra; 3D; AUDITORY BRAIN-STEM; SAFETY;
D O I
10.1097/MAO.0000000000002407
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis: A novel cochlea implant (CI) device magnet providing alignment to the static field of a magnetic resonance imaging (MRI) will lead to reduced torque, longitudinal forces, and demagnetization effects. The image void and distortion will be comparable to those obtained with standard CI magnets. Background: MRI investigations of CI users pose several challenges such as magnet dislocation, demagnetization, and may cause pain. The presence of a CI magnet within MRI field causes image distortions and may diminish the diagnostic value of an MRI procedure. Objective of this work is to evaluate magnetic forces and imaging properties of the novel CI magnet within 1.5 and 3T MRI. Methods: Forces and torque of the novel CI magnet were measured in both 1.5 and 3T MRI and compared with the standard magnet in 1.5T. One cadaver head was implanted with the CI devices containing the novel and standard magnets in different configurations reflecting clinical scenarios and imaging properties were assessed and compared. Results: In particular the torque has been reduced with the novel CI magnet in comparison to the standard one. Both CI magnets have not shown any signs of demagnetization. The image void and distortion was comparable between the two magnets for the main MRI clinical scanning protocols in 1.5T MRI. Conclusions: The novel CI magnet is safe to use for MRI investigations of CI users in 3T MRI without a need for bandaging and has acceptable level of image artefacts.
引用
收藏
页码:E966 / E974
页数:9
相关论文
共 50 条
  • [41] Conceptual Design of a 3T MRI Superconducting Magnet With Non-Thrust Face Integrated Former
    Yu, Xingen
    Wang, Chao
    Thomas, Adrian
    Ren, Zhongyou
    Ni, Cheng
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 773 - 776
  • [42] Design of a half-size 3T REBCO superconducting magnet with active shielding coils for MRI
    Yokoyama, S.
    Miura, H.
    Matsuda, T.
    Inoue, T.
    Morita, Y.
    Otake, S.
    Sato, S.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [43] Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3T
    Muftuler, LT
    Gulsen, G
    Sezen, KD
    Nalcioglu, O
    JOURNAL OF MAGNETIC RESONANCE, 2002, 155 (01) : 39 - 44
  • [44] Reduced Field of View APT Imaging of Rectum (RAPTOR) at 3T MRI Scanner *
    Chai, Xu-Bin
    Wang, Yi
    He, Zi-Jun
    Liu, Ai-Hua
    Xue, Rong
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2024, 51 (06) : 1471 - 1478
  • [45] Peritoneal carcinomatosis: imaging with 64-MDCT and 3T MRI with diffusion-weighted imaging
    F. Iafrate
    M. Ciolina
    P. Sammartino
    P. Baldassari
    M. Rengo
    P. Lucchesi
    S. Sibio
    F. Accarpio
    A. Di Giorgio
    A. Laghi
    Abdominal Imaging, 2012, 37 : 616 - 627
  • [46] Peritoneal carcinomatosis: imaging with 64-MDCT and 3T MRI with diffusion-weighted imaging
    Iafrate, F.
    Ciolina, M.
    Sammartino, P.
    Baldassari, P.
    Rengo, M.
    Lucchesi, P.
    Sibio, S.
    Accarpio, F.
    Di Giorgio, A.
    Laghi, A.
    ABDOMINAL IMAGING, 2012, 37 (04): : 616 - 627
  • [47] Functional MR angiography using phase contrast imaging technique at 3T MRI
    Kang, Chang-Ki
    Kim, Sang-Hoon
    Lee, Hyon
    Park, Chan-A
    Kim, Young-Bo
    Cho, Zang-Hee
    NEUROIMAGE, 2010, 50 (03) : 1036 - 1043
  • [48] Assessment of sedated pediatric brain with 3D-FLAIR sequence at 3T MRI
    Ozcan, Umit Aksoy
    Isik, Ugur
    Ozpinar, Alp
    Baykan, Nigar
    Dincer, Alp
    BRAIN & DEVELOPMENT, 2015, 37 (05): : 495 - 500
  • [49] Ammonia-weighted imaging by chemical exchange saturation transfer MRI at 3T
    Zoellner, Helge Joern
    Butz, Markus
    Kircheis, Gerald
    Klinker, Stefan
    Haeussinger, Dieter
    Schmitt, Benjamin
    Schnitzler, Alfons
    Wittsack, Hans-Joerg
    NMR IN BIOMEDICINE, 2018, 31 (09)
  • [50] Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T
    Wang, Z
    Wang, JJ
    Connick, TJ
    Wetmore, GS
    Detre, JA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 732 - 737