Quality assurance of measured depth dose for megavoltage photon beams

被引:0
|
作者
Thompson, AV [1 ]
Zhu, TC [1 ]
Bjärngard, BE [1 ]
机构
[1] Hosp Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
depth dose; quality assurance; analytical modeling;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have evaluated the use of a five-parameter analytical expression to perform quality assurance of measured fractional depth dose. Two of the parameters, attenuation and beam-hardening coefficients, are directly measured. The remaining three parameters are determined by fitting the product of measured depth doses anal the phantom-scatter factor, S-p(s), for various square field sizes (5 - 40 cm) in the region of electronic equilibrium. S-p(s) is the dose at a reference depth and field size s, normalized to the PQ x 10 cm(2) field size, excluding the head-scatter factor, H. It is obtained by the division of S-pc(c) and Pb(c), The data were fitted to a published analytic expression for the scatter-to-primary dose ratio, and modified to account for backscatter. We used a differential evolution algorithm for the minmax optimization of the relative errors. The electron disequilibrium factor, E; is also extrapoiated for all the field sizes. Ten photon beams were processed (6 and 18 MV, open and four solid wedges). Nine of the ten processed beams showed a maximum error of 1.8% with a mean error of 0.5%, One photon beam (6 MV, open) had a larger maximum error of 3.8%, Further investigation indicated that this error was caused by measurement errors for the 5 x 5 cm2 field. The maximum error was reduced to 1.8% when the depth dose was remeasured.
引用
收藏
页码:3108 / 3111
页数:4
相关论文
共 50 条
  • [41] The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments
    Mobit, PN
    Mayles, P
    Nahum, AE
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03): : 387 - 398
  • [42] SEMI-EMPIRICAL MODEL FOR DEPTH DOSE DISTRIBUTIONS OF MEGAVOLTAGE X-RAY-BEAMS
    AHUJA, SD
    STROUP, SL
    BOLIN, MG
    MEDICAL PHYSICS, 1980, 7 (05) : 537 - 544
  • [43] Quality assurance of central axis dose data for photon beams by means of a functional representation of the tissue phantom ratio
    Xiao, Y
    Altschuler, MD
    Bjarngard, BE
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08): : 2195 - 2206
  • [44] THE PROTOCOLS AND CODES OF PRACTICE USED FOR THE DETERMINATION OF ABSORBED DOSE IN MEGAVOLTAGE PHOTON AND ELECTRON-BEAMS
    WEATHERBURN, H
    NISBET, A
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1991, 19 (2-3) : 147 - 180
  • [45] Small-cavity chamber dose response to megavoltage photon beams in the presence of magnetic fields
    Cervantes, Y.
    Billas, I.
    Shipley, D.
    Duane, S.
    Bouchard, H.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S16 - S16
  • [47] Detector dose response in megavoltage small photon beams. I. Theoretical concepts
    Bouchard, Hugo
    Seuntjens, Jan
    Duane, Simon
    Kamio, Yuji
    Palmans, Hugo
    MEDICAL PHYSICS, 2015, 42 (10) : 6033 - 6047
  • [48] Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams
    Ito, Shotaro
    Araki, Fujio
    Ohno, Takeshi
    MEDICAL PHYSICS, 2020, 47 (04) : 1995 - 2004
  • [49] DOSE MEASUREMENT AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS USING TLDS
    PRADHAN, AS
    GOPALAKRISHNAN, AK
    IYER, PS
    MEDICAL PHYSICS, 1992, 19 (02) : 355 - 356
  • [50] Small-cavity chamber dose response in megavoltage photon beams coupled to magnetic fields
    Cervantes, Yunuen
    Billas, Ilias
    Shipley, David
    Duane, Simon
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):