Quality assurance of measured depth dose for megavoltage photon beams

被引:0
|
作者
Thompson, AV [1 ]
Zhu, TC [1 ]
Bjärngard, BE [1 ]
机构
[1] Hosp Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
depth dose; quality assurance; analytical modeling;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have evaluated the use of a five-parameter analytical expression to perform quality assurance of measured fractional depth dose. Two of the parameters, attenuation and beam-hardening coefficients, are directly measured. The remaining three parameters are determined by fitting the product of measured depth doses anal the phantom-scatter factor, S-p(s), for various square field sizes (5 - 40 cm) in the region of electronic equilibrium. S-p(s) is the dose at a reference depth and field size s, normalized to the PQ x 10 cm(2) field size, excluding the head-scatter factor, H. It is obtained by the division of S-pc(c) and Pb(c), The data were fitted to a published analytic expression for the scatter-to-primary dose ratio, and modified to account for backscatter. We used a differential evolution algorithm for the minmax optimization of the relative errors. The electron disequilibrium factor, E; is also extrapoiated for all the field sizes. Ten photon beams were processed (6 and 18 MV, open and four solid wedges). Nine of the ten processed beams showed a maximum error of 1.8% with a mean error of 0.5%, One photon beam (6 MV, open) had a larger maximum error of 3.8%, Further investigation indicated that this error was caused by measurement errors for the 5 x 5 cm2 field. The maximum error was reduced to 1.8% when the depth dose was remeasured.
引用
收藏
页码:3108 / 3111
页数:4
相关论文
共 50 条
  • [21] Reduction of the Skin Surface Dose for Megavoltage Photon Beams Passing Carbon Couch
    Tamura, M.
    Monzen, H.
    Matsumoto, K.
    Okumura, M.
    Nishimura, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2945 - 2945
  • [22] Tumour dose enhancement using modified megavoltage photon beams and contrast media
    Robar, JL
    Riccio, SA
    Martin, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (14): : 2433 - 2449
  • [23] BUILDUP REGION AND DEPTH OF DOSE MAXIMUM OF MEGAVOLTAGE X-RAY-BEAMS
    SIXEL, KE
    PODGORSAK, EB
    MEDICAL PHYSICS, 1994, 21 (03) : 411 - 416
  • [24] Depth for dose calibration in high energy photon beams
    Sjogren, R
    Karlsson, MG
    Karlsson, M
    Svensson, H
    RADIOTHERAPY AND ONCOLOGY, 1997, 43 (03) : 311 - 313
  • [25] Investigation of the effects of a carbon-fiber tabletop on the surface dose and attenuation dose for megavoltage photon beams
    Gursoy, G.
    Eser, E.
    Yigitoglu, I
    Koc, H.
    Kahraman, F. C.
    Yamcicier, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 235 - 241
  • [26] The Beam Quality Dependence of a Radiophotoluminescent Glass Dosimeter in Megavoltage Photon and Electron Beams
    Araki, F.
    Ohno, T.
    Yoshiyama, F.
    Kohno, T.
    Wulff, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Evaluation of uncertainty predictions and dose output for model-based dose calculations for megavoltage photon beams
    Olofsson, Jorgen
    Nyholm, Tufve
    Georg, Dietmar
    Ahnesjo, Anders
    Karlsson, Mikael
    MEDICAL PHYSICS, 2006, 33 (07) : 2548 - 2556
  • [28] Impact of transverse magnetic fields on dose response of a nanoDot OSLD in megavoltage photon beams
    Ito, Shotaro
    Araki, Fujio
    Hoshida, Kento
    Ohno, Takeshi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 70 : 153 - 160
  • [29] Surface dose measurements in and out of field: Implications for breast radiotherapy with megavoltage photon beams
    Lonski, Peta
    Ramachandran, Prabhakar
    Franich, Rick
    Kron, Tomas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (04): : 318 - 323
  • [30] BACKSCATTER DOSE PERTURBATION AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS
    DAS, IJ
    KAHN, FM
    MEDICAL PHYSICS, 1989, 16 (03) : 367 - 375