First Clinical Evaluation of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation

被引:89
|
作者
Cavus, Erol [1 ]
Neumann, Tobias [1 ]
Doerges, Volker [1 ]
Moeller, Thora [2 ]
Scharf, Edwin [1 ]
Wagner, Klaus [2 ]
Bein, Berthold [1 ]
Serocki, Goetz [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Klinikum Suedstadt Rostock, Dept Anaesthesiol & Intens Care Med, Rostock, Germany
来源
ANESTHESIA AND ANALGESIA | 2011年 / 112卷 / 02期
关键词
TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; AIRWAY MANAGEMENT; EMERGENCY;
D O I
10.1213/ANE.0b013e31820553fb
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In the present preliminary study we evaluated the C-MAC (R) D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11(5-45) seconds and for successful intubation 17(3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required. (Anesth Analg 2011;112:382-5)
引用
收藏
页码:382 / 385
页数:4
相关论文
共 50 条
  • [1] Rational Design of End-Points to Evaluate Performance of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation Response
    Cavus, Erol
    Doerges, Volker
    Wagner, Klaus
    Serocki, Goetz
    ANESTHESIA AND ANALGESIA, 2011, 113 (01): : 203 - 204
  • [2] Clinical evaluation of the C-MAC D-Blade videolaryngoscope in severely obese patients: a pilot study
    Cattano, D.
    Corso, R. M.
    Altamirano, A. V.
    Patel, C. B.
    Meese, M. M.
    Seitan, C.
    Hagberg, C. A.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) : 647 - 648
  • [3] Comparison between bougies and stylets for simulated tracheal intubation with the C-MAC D-blade videolaryngoscope
    Batuwitage, Bisanth
    McDonald, Andrew
    Nishikawa, Koji
    Lythgoe, Daniel
    Mercer, Simon
    Charters, Peter
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (06) : 400 - 405
  • [4] Determining the best introducer for intubating with the C-MAC® D-blade videolaryngoscope
    Batuwitage, B.
    McDonald, A.
    Nishikawa, K.
    Lythgoe, D.
    Mercer, S.
    Charters, P.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (05) : 883 - 884
  • [5] C-MAC® pediatric D-blade for intubation in a child with Hurler syndrome
    Kumar, Kanil R.
    Kalagara, Reshma
    Subramaniam, Rajeshwari
    Singh, Swati
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2022, 38 (04) : 671 - 672
  • [6] Clinical evaluation of C-Mac D-Blade video laryngoscope: randomized comparison with C-Mac Blade and direct laryngoscopy
    Hostic, V.
    Maldini, B.
    Novotny, Z.
    Hodzovic, I.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E905 - E906
  • [7] Comparison of Different Types of Stylets with No-Stylet Technique for Intubation with C-MAC D-Blade® Videolaryngoscope in Simulated Difficult Airway: A Prospective Randomised Study
    Goel, Rishika
    Anand, Lakesh Kumar
    Singh, Manpreet
    Jindal, Swati
    Rani, Mala
    Kaur, Arshdeep
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (06) : 445 - 452
  • [8] Awake intubation with C-MAC videolaryngoscope in a patient with difficult airway
    Vaishnavi, B. D.
    Syal, Rashmi
    Vyas, Raksha
    Bihani, Pooja
    INDIAN JOURNAL OF ANAESTHESIA, 2021, 65 (03) : 253 - +
  • [9] Comparison of cervical spine motion during intubation with a C-MAC D-Blade® and an LMA Fastrach®
    Ozkan, D.
    Altinsoy, S.
    Sayin, M.
    Dolgun, H.
    Ergil, J.
    Donmez, A.
    ANAESTHESIST, 2019, 68 (02): : 90 - 96
  • [10] Comparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways
    Kilicaslan, Alper
    Topal, Ahmet
    Erol, Atilla
    Uzun, Sema Tuncer
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2014, 42 (04) : 182 - 189