Non-invasive oscillometric versus invasive arterial blood pressure measurements in critically ill patients: A post hoc analysis of a prospective observational study

被引:29
|
作者
Kaufmann, Thomas [1 ]
Cox, Eline G. M. [2 ]
Wiersema, Renske [2 ]
Hiemstra, Bart [1 ,2 ]
Eck, Ruben J. [3 ]
Koster, Geert [2 ]
Scheeren, Thomas W. L. [1 ]
Keus, Frederik [2 ]
Saugel, Bernd [4 ,5 ]
van der Horst, Iwan C. C. [2 ,6 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, POB 30-001, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Crit Care, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Groningen, Netherlands
[4] Univ Med Ctr Hamburg Eppendorf, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, Hamburg, Germany
[5] Outcomes Res Consortium, Cleveland, OH USA
[6] Maastricht Univ, Maastricht Univ Med Ctr, Dept Intens Care, Maastricht, Netherlands
关键词
Arterial pressure; Vascular access devices; Oscillometry; Intensive care; Norepinephrine; Vasoactive medication; SHOCK; AGREEMENT; CUFF;
D O I
10.1016/j.jcrc.2020.02.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The aimwas to compare non-invasive blood pressuremeasurementswith invasive blood pressure measurements in critically ill patients. Methods: Non-invasive blood pressure was measured via automated brachial cuff oscillometry, and simultaneously the radial arterial catheter-derived measurement was recorded as part of a prospective observational study. Measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) were compared using Bland-Altman and error grid analyses. Results: Paired measurements of blood pressurewere available for 736 patients. Observedmean difference (+/- SD, 95% limits of agreement) between oscillometrically and invasively measured blood pressure was 0.8 mmHg (+/- 15.7 mmHg, -30.2 to 31.7 mmHg) for SAP, -2.9 mmHg (+/- 11.0 mmHg, -24.5 to 18.6 mmHg) for DAP, and -1.0 mmHg (+/- 10.2 mmHg, -21.0 to 18.9 mmHg) for MAP. Error grid analysis showed that the proportions of measurements in risk zones A to E were 78.3%, 20.7%, 1.0%, 0%, and 0.1% for MAP. Conclusion: Non-invasive blood pressure measurements using brachial cuff oscillometry showed large limits of agreement compared to invasivemeasurements in critically ill patients. Error grid analysis showed that measurement differences between oscillometry and the arterial catheter would potentially have triggered at least lowrisk treatment decisions in one in five patients. (c) 2020 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http:// creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [31] Oscillometric non-invasive blood pressure measurements: the influence of the make of instrument on readings?
    J. N. Amoore
    W. B. Geake
    D. H. T. Scott
    Medical and Biological Engineering and Computing, 1997, 35 : 131 - 134
  • [32] Oscillometric non-invasive blood pressure measurements: The influence of the make of instrument on readings?
    Amoore, J.N.
    Geake, W.B.
    Scott, D.H.T.
    Medical and Biological Engineering and Computing, 1997, 35 (02): : 131 - 134
  • [33] Feasibility study of continuous non-invasive blood pressure measurement in critically ill children
    C Hofhuizen
    J Lemson
    L van de Sant
    O Schraa
    J Settels
    J van der Hoeven
    Critical Care, 10 (Suppl 1):
  • [34] Validation study of Nexfin® continuous non-invasive blood pressure monitoring in critically ill adult patients
    Ameloot, K.
    Van de Vijver, K.
    Van Regenmortel, N.
    De Laet, I.
    Schoonheydt, K.
    Dits, H.
    Broch, O.
    Bein, B.
    Malbrain, M. L. N. G.
    MINERVA ANESTESIOLOGICA, 2014, 80 (12) : 1294 - 1301
  • [35] Smartphone-Based versus Non-Invasive Automatic Oscillometric Brachial Cuff Blood Pressure Measurements: A Prospective Method Comparison Volunteer Study
    Delmotte, Lila
    Desebbe, Olivier
    Alexander, Brenton
    Kouz, Karim
    Coeckelenbergh, Sean
    Schoettker, Patrick
    Turgay, Tuna
    Joosten, Alexandre
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (01):
  • [36] Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
    Ali Araghi
    Joseph J Bander
    Jorge A Guzman
    Critical Care, 10
  • [37] Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
    Araghi, Ali
    Bander, Joseph J.
    Guzman, Jorge A.
    CRITICAL CARE, 2006, 10 (02):
  • [38] Correlation Between Blood Pressure Measurement by Non-invasive and Invasive Methods in Critically-ill Children
    Krishna, B. Vamshi
    Das, Suman
    Sen, Sandip
    INDIAN PEDIATRICS, 2018, 55 (04) : 297 - 300
  • [39] Correlation Between Blood Pressure Measurement by Non-invasive and Invasive Methods in Critically-ill Children
    B. Vamshi Krishna
    Suman Das
    Sandip Sen
    Indian Pediatrics, 2018, 55 : 297 - 300
  • [40] Calibration of oscillometric non-invasive devices for monitoring blood pressure
    Doh, Il
    Lim, Hyun Kyoon
    Ahn, Bongyoung
    METROLOGIA, 2015, 52 (02) : 291 - 296