Non-invasive oscillometric versus invasive arterial blood pressure measurements in critically ill patients: A post hoc analysis of a prospective observational study

被引:29
|
作者
Kaufmann, Thomas [1 ]
Cox, Eline G. M. [2 ]
Wiersema, Renske [2 ]
Hiemstra, Bart [1 ,2 ]
Eck, Ruben J. [3 ]
Koster, Geert [2 ]
Scheeren, Thomas W. L. [1 ]
Keus, Frederik [2 ]
Saugel, Bernd [4 ,5 ]
van der Horst, Iwan C. C. [2 ,6 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, POB 30-001, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Crit Care, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Groningen, Netherlands
[4] Univ Med Ctr Hamburg Eppendorf, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, Hamburg, Germany
[5] Outcomes Res Consortium, Cleveland, OH USA
[6] Maastricht Univ, Maastricht Univ Med Ctr, Dept Intens Care, Maastricht, Netherlands
关键词
Arterial pressure; Vascular access devices; Oscillometry; Intensive care; Norepinephrine; Vasoactive medication; SHOCK; AGREEMENT; CUFF;
D O I
10.1016/j.jcrc.2020.02.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The aimwas to compare non-invasive blood pressuremeasurementswith invasive blood pressure measurements in critically ill patients. Methods: Non-invasive blood pressure was measured via automated brachial cuff oscillometry, and simultaneously the radial arterial catheter-derived measurement was recorded as part of a prospective observational study. Measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) were compared using Bland-Altman and error grid analyses. Results: Paired measurements of blood pressurewere available for 736 patients. Observedmean difference (+/- SD, 95% limits of agreement) between oscillometrically and invasively measured blood pressure was 0.8 mmHg (+/- 15.7 mmHg, -30.2 to 31.7 mmHg) for SAP, -2.9 mmHg (+/- 11.0 mmHg, -24.5 to 18.6 mmHg) for DAP, and -1.0 mmHg (+/- 10.2 mmHg, -21.0 to 18.9 mmHg) for MAP. Error grid analysis showed that the proportions of measurements in risk zones A to E were 78.3%, 20.7%, 1.0%, 0%, and 0.1% for MAP. Conclusion: Non-invasive blood pressure measurements using brachial cuff oscillometry showed large limits of agreement compared to invasivemeasurements in critically ill patients. Error grid analysis showed that measurement differences between oscillometry and the arterial catheter would potentially have triggered at least lowrisk treatment decisions in one in five patients. (c) 2020 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http:// creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [21] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Hidehiko Komine
    Yoshiyuki Asai
    Takashi Yokoi
    Mutsuko Yoshizawa
    BioMedical Engineering OnLine, 11
  • [22] The accuracy of blood pressure measured by arterial line and non-invasive cuff in critically ill children
    Joffe, Rachel
    Duff, Jonathan
    Guerra, Gonzalo Garcia
    Pugh, Jodie
    Joffe, Ari R.
    CRITICAL CARE, 2016, 20
  • [23] The accuracy of blood pressure measured by arterial line and non-invasive cuff in critically ill children
    Rachel Joffe
    Jonathan Duff
    Gonzalo Garcia Guerra
    Jodie Pugh
    Ari R. Joffe
    Critical Care, 20
  • [24] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Komine, Hidehiko
    Asai, Yoshiyuki
    Yokoi, Takashi
    Yoshizawa, Mutsuko
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [25] Non-invasive monitoring of blood glucose in critically ill patients
    Weinstein, A.
    Herzenstein, O.
    Gabis, E.
    Singer, P.
    DIABETOLOGIA, 2008, 51 : S430 - S430
  • [26] NON-INVASIVE MONITORING OF BLOOD PARAMETERS IN CRITICALLY ILL PATIENTS
    Weinstein, Aharon
    Herzenstein, Olga
    Gabis, Ephraim
    Singer, Pierre
    CRITICAL CARE MEDICINE, 2008, 36 (12) : A67 - A67
  • [27] Arterial Pressure Monitoring in Pediatric Patients Undergoing Cardiac Surgery: An Observational Study Comparing Invasive and Non-invasive Measurements
    Ricci, Zaccaria
    Brogi, Jessica
    De Filippis, Sara
    Caccavelli, Rossella
    Morlacchi, Matteo
    Romagnoli, Stefano
    PEDIATRIC CARDIOLOGY, 2019, 40 (06) : 1231 - 1237
  • [28] Arterial Pressure Monitoring in Pediatric Patients Undergoing Cardiac Surgery: An Observational Study Comparing Invasive and Non-invasive Measurements
    Zaccaria Ricci
    Jessica Brogi
    Sara De Filippis
    Rossella Caccavelli
    Matteo Morlacchi
    Stefano Romagnoli
    Pediatric Cardiology, 2019, 40 : 1231 - 1237
  • [29] Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
    Cutuli, Salvatore L.
    Osawa, Eduardo A.
    Eyeington, Christopher T.
    Proimos, Helena
    Canet, Emmanuel
    Young, Helen
    Peck, Leah
    Eastwood, Glenn M.
    Glassford, Neil J.
    Bailey, Michael
    Bellomo, Rinaldo
    CRITICAL CARE AND RESUSCITATION, 2021, 23 (03) : 346 - 353
  • [30] Oscillometric non-invasive blood pressure measurements: The influence of the make of instrument on readings?
    Amoore, JN
    Geake, WB
    Scott, DHT
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (02) : 131 - 134