Focusing hard X-ray with a single lens

被引:13
|
作者
Zhang, YP
Katoh, T
Kagoshima, Y
Matui, J
Tsusaka, Y
机构
[1] Sumitomo Heavy Ind Ltd, Tanashi, Tokyo 1888585, Japan
[2] Himeji Inst Technol, Fac Sci, Kyoto 6791297, Japan
来源
关键词
X-ray microbeam; microbeam array; single lens; high transmission; synchrotron radiation;
D O I
10.1143/JJAP.40.L75
中图分类号
O59 [应用物理学];
学科分类号
摘要
We show that a 10 keV X-ray has been focused into 3.4-8.4 mum at a focal length F = 0.4-1.5 m with a single refractive lens and such X-ray microbeams: can be generated in array. For the beam from a synchrotron radiation source, which typically had a diameter phi = 100 mum, transmissions of our lenses were measured to be T = 54-85%. X-ray imaging of a copper mesh was carried out with a magnification of about 5 in one dimension and the imaging resolution was evaluated to be 0.9 mum. Our lenses have performed well under a flux of 1.1 x 10(11) photons.s(-1).mm(-2), showing no visible damage due to the X-ray exposure.
引用
收藏
页码:L75 / L77
页数:3
相关论文
共 50 条
  • [41] X-Ray Focusing Characteristics of Meridional Lobster-Eye Lens
    Han Yeming
    Fu Yuegang
    Ouyang Mingzhao
    Hu Yuan
    Qin Tianling
    Li Yang
    LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (06)
  • [42] 13.1 micrometers hard X-ray focusing by a new type monocapillary X-ray optic designed for common laboratory X-ray source
    Sun, Xuepeng
    Zhang, Xiaoyun
    Zhu, Yu
    Wang, Yabing
    Shang, Hongzhong
    Zhang, Fengshou
    Liu, Zhiguo
    Sun, Tianxi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 13 - 17
  • [43] X-ray nanometer focusing at the SSRF based on a multilayer Laue lens
    朱京涛
    涂昱淳
    李浩川
    岳帅鹏
    黄秋实
    李爱国
    王占山
    Chinese Physics C, 2015, 39 (12) : 104 - 106
  • [44] X-ray nanometer focusing at the SSRF based on a multilayer Laue lens
    Zhu Jing-Tao
    Tu Yu-Chun
    Li Hao-Chuan
    Yue Shuai-Peng
    Huang Qiu-Shi
    Li Ai-Guo
    Wang Zhan-Shan
    CHINESE PHYSICS C, 2015, 39 (12)
  • [45] X-Ray “knife” as a submicrometer tool for studying focusing lens quality
    A. N. Artemiev
    A. G. Maevskii
    N. A. Artemiev
    A. A. Demkiv
    Yu. I. Dudchik
    A. V. Zabelin
    B. Ph. Kirillov
    V. V. Kvardakov
    F. F. Komarov
    O. V. Naida
    A. V. Porokhova
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2008, 2 : 879 - 883
  • [46] Application of monolithic polycapillary X-ray lens in focusing of synchrotron radiation
    Sun, TX
    Xie, YN
    Liu, ZG
    Liu, T
    Hu, TD
    Yang, J
    Chu, XL
    Ding, XL
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 : 137 - 139
  • [47] X-ray focusing using an inclined Bragg-reflection lens
    National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973, United States
    不详
    J. Synchrotron Radiat., 5 (973-978):
  • [48] X-Ray "Knife" as a Submicrometer Tool for Studying Focusing Lens Quality
    Artemiev, A. N.
    Maevskii, A. G.
    Artemiev, N. A.
    Demkiv, A. A.
    Dudchik, Yu. I.
    Zabelin, A. V.
    Kirillov, B. Ph.
    Kvardakov, V. V.
    Komarov, F. F.
    Naida, O. V.
    Porokhova, A. V.
    JOURNAL OF SURFACE INVESTIGATION, 2008, 2 (06): : 879 - 883
  • [49] Collimating/focusing optical system designed for hard X-ray communication
    Wang, Yiyang
    Liu, Yunpeng
    Mu, Junxu
    Feng, Zhaopeng
    Tang, Xiaobin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1016
  • [50] Ultimate limitations in the performance of kinoform lenses for hard x-ray focusing
    Gorelick, S.
    De Jonge, M. D.
    Kewish, C. M.
    De Marco, A.
    OPTICA, 2019, 6 (06): : 790 - 793