Focusing hard X-ray with a single lens

被引:13
|
作者
Zhang, YP
Katoh, T
Kagoshima, Y
Matui, J
Tsusaka, Y
机构
[1] Sumitomo Heavy Ind Ltd, Tanashi, Tokyo 1888585, Japan
[2] Himeji Inst Technol, Fac Sci, Kyoto 6791297, Japan
来源
关键词
X-ray microbeam; microbeam array; single lens; high transmission; synchrotron radiation;
D O I
10.1143/JJAP.40.L75
中图分类号
O59 [应用物理学];
学科分类号
摘要
We show that a 10 keV X-ray has been focused into 3.4-8.4 mum at a focal length F = 0.4-1.5 m with a single refractive lens and such X-ray microbeams: can be generated in array. For the beam from a synchrotron radiation source, which typically had a diameter phi = 100 mum, transmissions of our lenses were measured to be T = 54-85%. X-ray imaging of a copper mesh was carried out with a magnification of about 5 in one dimension and the imaging resolution was evaluated to be 0.9 mum. Our lenses have performed well under a flux of 1.1 x 10(11) photons.s(-1).mm(-2), showing no visible damage due to the X-ray exposure.
引用
收藏
页码:L75 / L77
页数:3
相关论文
共 50 条
  • [31] Focusing of hard X-ray radiation by layer zone plate
    Asadchikov, VE
    Beloglazov, VI
    Vinogradov, AV
    Voronov, DL
    Kondratenko, VV
    Kopylov, YV
    Lebedev, NF
    Ponomarenko, AG
    Popov, AV
    Postnov, AA
    Savel'ev, SV
    Fedorenko, AI
    CRYSTALLOGRAPHY REPORTS, 1999, 44 (04) : 546 - 553
  • [32] X-ray focusing using an x-ray lens composed of multi-square polycapillary slices
    潘凯
    易天成
    王瞾
    周末
    李玉德
    刘志国
    林晓燕
    孙天希
    Chinese Physics B, 2022, (02) : 323 - 329
  • [33] X-Ray Fluorescence Technology Based on Monolithic Polycapillary X-Ray Focusing Lens in Helium Atmosphere
    Li Hui-quan
    Sun Xue-peng
    Shao Shang-kun
    Yuan Tian-yu
    Hua Lu
    Zhong Yu-chuan
    Liu Zhi-guo
    Sun Tian-xi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (08) : 2198 - 2201
  • [34] Numerical design of polycapillary X-ray optics as both a focusing X-ray lens and a vacuum window
    Jiang, Bowen
    Liu, Zhiguo
    Sun, Weiyuan
    Sun, Xuepeng
    Li, Fangzuo
    Ma, Yongzhong
    Sun, Tianxi
    VACUUM, 2015, 121 : 1 - 4
  • [35] X-ray focusing using an x-ray lens composed of multi-square polycapillary slices
    Pan, Kai
    Yi, Tian-Cheng
    Wang, Zhao
    Zhou, Mo
    Li, Yu-De
    Liu, Zhi-Guo
    Lin, Xiao-Yan
    Sun, Tian-Xi
    CHINESE PHYSICS B, 2022, 31 (02)
  • [36] Study of the monolithic x-ray focusing lens and its application in microbeam x-ray fluorescence analysis
    Xie, JD
    Yan, YM
    Ding, XL
    He, YJ
    Pan, QL
    X-RAY SPECTROMETRY, 2000, 29 (04) : 305 - 309
  • [37] Theoretical investigation of higher orders optimized Multilayer Laue Lens for hard x-ray nano-focusing
    Huang, Qiushi
    Zhu, Jingtao
    Li, Haochuan
    Wang, Zhanshan
    Tang, Yongjian
    OPTICS COMMUNICATIONS, 2012, 285 (24) : 5496 - 5499
  • [38] Hard X-ray imaging by a spherical compound refractive lens
    Huang, Chengchao
    Mu, Baozhong
    Wang, Zhanshan
    Chen, Lingyan
    Dudchik, Yu. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (02): : 446 - 449
  • [39] Field-emission X-ray Sources with an Anisotropic Focusing Lens for Isotropic X-ray Focal Spots
    Jung, Sunshin
    Chang, Won Suk
    Kim, Beom Seok
    Kim, Daeho
    Seol, Seung Kwon
    Park, Kyu Chang
    Lee, Yang Doo
    Ju, Byeong-Kwon
    Park, Hun-Kuk
    2012 25TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2012, : 66 - +
  • [40] High resolution scanned-slit x-ray imaging using a refractive lens for x-ray focusing
    Beuville, E
    Cahn, R
    Cederstrom, B
    Danielsson, M
    Hasegawa, B
    Lundqvist, M
    Hall, A
    Luo, L
    Nygren, D
    Oltman, E
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 95 - 103