Technical Note: Ion chamber angular dependence in a magnetic field

被引:14
|
作者
Reynolds, Michael [1 ]
Rathee, Satyapal [1 ,2 ]
Fallone, B. Gino [2 ,3 ,4 ]
机构
[1] Univ Alberta, Med Phys Div, Dept Oncol, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
[2] Cross Canc Inst, Dept Med Phys, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
[3] Univ Alberta, Dept Oncol, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
[4] Univ Alberta, Dept Phys, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
关键词
angular dependence; ion chamber; Linac-MR; magnetic field; Monte Carlo; setup inaccuracies; MV RADIOTHERAPY ACCELERATOR; MONTE-CARLO SIMULATIONS; REFERENCE DOSIMETRY; IONIZATION-CHAMBER; MRI SCANNER; DOSE DEPOSITION; TRANSPORT; PENELOPE; ALGORITHM; ELECTRONS;
D O I
10.1002/mp.12405
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: There have been several studies investigating dose deposition effects within radiation detectors in the presence of a magnetic field. However, to date there has only been a passing investigation which explicitly investigates detector dose-response as a function of detector orientation. Herein we will investigate the dose-response as a function angular orientation of a PR06C ionization chamber. We will also benchmark the Monte Carlo code PENELOPE with the newly developed magnetic field Fano test. Methods: The PENELOPE Monte Carlo package was used to simulate a PR06C ionization chamber in 0.35 T through 1.5 T magnetic fields oriented either parallel or orthogonal to an incident 6 MV radiation beam. The ionization chamber was rotated through a number of polar and azimuthal angles. The dose deposited within the chamber at each angular position and magnetic field strength was scored then normalized to that deposited in the same orientation with no magnetic field. The simulation was also benchmarked via a Fano test in magnetic field. Results: The Fano test yielded a 0.4% difference between simulation and expected result, which is similar to previous findings and sufficient for the purposes of this study. The angular dose-response map in all cases where the magnetic field is oriented orthogonal to the radiation beam is quite varied and can range from 0.89 to 1.08. Angular deviations as small as 3 degrees can lead to dose-response changes in excess of 1%. When the magnetic field is parallel to the photon beam, the angular dose-response map is homogeneous and less than 1% below 1.0 T. Conclusions: Within a magnetic field-oriented orthogonal to the radiation beam, the ionization chamber dose-response fluctuates greatly as a function of polar and azimuthal angle, where a parallel field yields a more homogeneous dose-response.(C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4322 / 4328
页数:7
相关论文
共 50 条
  • [41] Angular dependence of upper critical field
    Takanaka, K
    Kishi, H
    Kuboya, K
    PHYSICA C, 1998, 301 (3-4): : 243 - 245
  • [42] Underlying mechanism of the magnetic field dependence of a plane-parallel chamber in proton beams
    Blum, Isabel
    Wong, Jing Syuen
    Padre, Krishna Godino
    Stolzenberg, Jessica
    Baumann, Kilian-Simon
    Fuchs, Hermann
    Poppe, Bjoern
    Looe, Hui Khee
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3386 - S3388
  • [43] EFFECT OF MAGNETIC VISCOSITY ON THE ANGULAR-DEPENDENCE OF COERCIVE FIELD IN PARTICULATE RECORDING MEDIA
    TOBIN, VM
    OSEROFF, SB
    SCHULTZ, S
    SHARROCK, MP
    IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (05) : 3653 - 3655
  • [44] MAGNETIC FIELD DEPENDENCE OF AM-243 ALPHA-GAMMA-ANGULAR CORRELATIONS
    SIEGBAHN, K
    ASARO, F
    PHYSICS LETTERS, 1962, 2 (07): : 323 - 325
  • [45] POTENTIALITY OF STUDIES OF SUPERLATTICE STRUCTURES ON ANGULAR-DEPENDENCE OF A CRITICAL MAGNETIC-FIELD
    MINENKO, EV
    KULIK, IO
    PISMA V ZHURNAL TEKHNICHESKOI FIZIKI, 1987, 13 (07): : 422 - 427
  • [46] Magnetic field angular dependence of AC losses in Bi-2223 superconducting wires
    Iwakuma, M
    Fukuda, Y
    Fukui, M
    Kajikawa, K
    Funaki, K
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2003, 392 : 1096 - 1101
  • [47] ANGULAR DEPENDENCE OF HYPERFINE STRUCTURE FOR THE COPPER ION
    CARR, EF
    KIKUCHI, C
    PHYSICAL REVIEW, 1950, 80 (06): : 1107 - 1107
  • [48] Technical Note: FLASH radiotherapy monitor chamber signal conditioning
    Snyder, Michael
    Vadas, Jessica
    Musselwhite, John
    Halford, Robert
    Wilson, George
    Stevens, Craig
    Yan, Di
    MEDICAL PHYSICS, 2021, 48 (02) : 791 - 795
  • [49] Magnetic field profile dependence of zirconium flux in sputtering ion sources
    Suzuki, T
    Kawai, Y
    Saburi, T
    Fujii, Y
    Kitayama, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 735 - 737
  • [50] A Systematic Study On the Angular Dependence of 2D Ion Chamber Array for Accurate IMRT Plan Quality Assurance
    Xu, J.
    Liu, J.
    Veltchev, I.
    Ma, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E691 - E691