Technical Note: Ion chamber angular dependence in a magnetic field

被引:14
|
作者
Reynolds, Michael [1 ]
Rathee, Satyapal [1 ,2 ]
Fallone, B. Gino [2 ,3 ,4 ]
机构
[1] Univ Alberta, Med Phys Div, Dept Oncol, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
[2] Cross Canc Inst, Dept Med Phys, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
[3] Univ Alberta, Dept Oncol, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
[4] Univ Alberta, Dept Phys, 11560 Univ Ave, Edmonton, AB T6G 1Z2, Canada
关键词
angular dependence; ion chamber; Linac-MR; magnetic field; Monte Carlo; setup inaccuracies; MV RADIOTHERAPY ACCELERATOR; MONTE-CARLO SIMULATIONS; REFERENCE DOSIMETRY; IONIZATION-CHAMBER; MRI SCANNER; DOSE DEPOSITION; TRANSPORT; PENELOPE; ALGORITHM; ELECTRONS;
D O I
10.1002/mp.12405
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: There have been several studies investigating dose deposition effects within radiation detectors in the presence of a magnetic field. However, to date there has only been a passing investigation which explicitly investigates detector dose-response as a function of detector orientation. Herein we will investigate the dose-response as a function angular orientation of a PR06C ionization chamber. We will also benchmark the Monte Carlo code PENELOPE with the newly developed magnetic field Fano test. Methods: The PENELOPE Monte Carlo package was used to simulate a PR06C ionization chamber in 0.35 T through 1.5 T magnetic fields oriented either parallel or orthogonal to an incident 6 MV radiation beam. The ionization chamber was rotated through a number of polar and azimuthal angles. The dose deposited within the chamber at each angular position and magnetic field strength was scored then normalized to that deposited in the same orientation with no magnetic field. The simulation was also benchmarked via a Fano test in magnetic field. Results: The Fano test yielded a 0.4% difference between simulation and expected result, which is similar to previous findings and sufficient for the purposes of this study. The angular dose-response map in all cases where the magnetic field is oriented orthogonal to the radiation beam is quite varied and can range from 0.89 to 1.08. Angular deviations as small as 3 degrees can lead to dose-response changes in excess of 1%. When the magnetic field is parallel to the photon beam, the angular dose-response map is homogeneous and less than 1% below 1.0 T. Conclusions: Within a magnetic field-oriented orthogonal to the radiation beam, the ionization chamber dose-response fluctuates greatly as a function of polar and azimuthal angle, where a parallel field yields a more homogeneous dose-response.(C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4322 / 4328
页数:7
相关论文
共 50 条
  • [31] Effects of Magnetic Field on Plasma Confinement of an Ion Thruster Discharge Chamber
    Guo, Shenglong
    Jin, Xiaolin
    Lei, Li
    Li, Bin
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (11) : 3358 - 3364
  • [32] Effects of magnetic field topography on the ion thruster discharge chamber performance
    Chen, Juanjuan
    Geng, Hai
    Meng, Wei
    Yan, Nengwen
    Hu, Jing
    Li, Xingda
    AIP ADVANCES, 2024, 14 (08)
  • [33] Technical Note: Effect of magnetic fields on the microdosimetry of carbon-ion beams
    Dai, Tianyuan
    Li, Qiang
    Liu, Xinguo
    Dai, Zhongying
    He, Pengbo
    Ma, Yuanyuan
    Shen, Guosheng
    Chen, Weiqiang
    Zhang, Hui
    Meng, Qianqian
    Zhang, Xiaofang
    MEDICAL PHYSICS, 2019, 46 (08) : 3746 - 3750
  • [34] THE EFFECT OF THE ANGULAR-DEPENDENCE OF THE PARTICLE NUCLEATION FIELD ON THE MAGNETIC RECORDING PROCESSES
    BERTRAM, HN
    IEEE TRANSACTIONS ON MAGNETICS, 1984, 20 (06) : 2094 - 2104
  • [35] Technical note: Angular dependence in fiber optic dosimetry using YVO4:Eu3+
    Martinez, Nahuel
    Fernandez, Yohanna
    Machello, Soledad
    Molina, Pablo
    Massa, Jose
    Santiago, Martin
    MEDICAL PHYSICS, 2023, 50 (07) : 4645 - 4650
  • [36] Technical Note: Enhancing the surface dose using a weak longitudinal magnetic field
    Carlone, Marco
    Tadic, Tony
    Keller, Harald
    Rezaee, Mohammad
    Jaffray, David
    MEDICAL PHYSICS, 2016, 43 (06) : 2927 - 2932
  • [37] Angular dependence of coercivity in magnetic nanotubes
    Escrig, J.
    Daub, M.
    Landeros, P.
    Nielsch, K.
    Altbir, D.
    NANOTECHNOLOGY, 2007, 18 (44)
  • [38] Angular dependence of upper critical field
    Takanaka, Kenji
    Kishi, Hiroki
    Kuboya, Koichi
    Physica C: Superconductivity and its Applications, 1998, 301 (3-4): : 243 - 245
  • [39] ANGULAR DEPENDENCE OF THE SUPERCONDUCTING NUCLEATION FIELD
    TINKHAM, M
    PHYSICS LETTERS, 1964, 9 (03): : 217 - 218
  • [40] Model for the angular dependence of critical currents in technical superconductors
    Long, N. J.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2008, 21 (02):