Certain proton reactions emit fast neutrons, and this study examines the feasibility of measuring the neutrons emitted from a typical medical 18 MeV proton cyclotron using prompt gamma neutron activation on chlorine. This neutron detection method, employed by previous studies, has been deemed successful and highly promising. The measurement system includes a gamma radiation scintillator, for example NaI(Tl), with a spectrometry setup facing a convertor that contains a chlorine solution or compounds thereof. In its natural state, elemental chlorine is a chemically unstable gas, making its use as a convertor challenging. Therefore, chlorine is usually dissolved in solutions. Such solutions are diluted with water and contain hydrogen atoms that interact intensively with the neutrons and may interrupt their detection. Accordingly, in this study, a 25.5 L container of KCl powder was placed in front of a NaI(Tl) (7.62 cm diameter by 7.62 cm length) spectrometer near a cyclotron facility. The gamma radiation spectroscopy allowed the identification of the chlorine INS gamma line at 788 keV, alongside the K-40 gamma peak. In addition, it was possible to detect the fast neutrons using a total-counting mode, when the INS counts appear above the K-40 counting level. The chlorine INS peak in the KCl convertor was detected simultaneously during the cyclotron operations and provided a direct indication of neutron exposure around the cyclotron. We conclude that using KCl as a converter, with a NaI(Tl) gamma rays counter, is successful in detecting cyclotron-produced neutron emissions.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [31] CHEMICAL PROCESSING OF CYCLOTRON-PRODUCED GA-67
    BROWN, LC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (11): : 710 - &
  • [32] CYCLOTRON-PRODUCED SHORT-LIVED RADIONUCLIDES IN MEDICINE
    BROWNELL, GL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (05): : 770 - 770
  • [33] Purification of cyclotron-produced 203Pb for labeling Herceptin
    Garmestani, K
    Milenic, DE
    Brady, ED
    Plascjak, PS
    Brechbiel, MW
    NUCLEAR MEDICINE AND BIOLOGY, 2005, 32 (03) : 301 - 305
  • [34] Methods for the Determination of Transition Metal Impurities in Cyclotron-Produced Radiometals
    Forgacs, Viktoria
    Fekete, Aniko
    Gyuricza, Barbara
    Szucs, Daniel
    Trencsenyi, Gyorgy
    Szikra, Dezso
    PHARMACEUTICALS, 2022, 15 (02)
  • [35] Radiochemical purification of cyclotron-produced lanthanide isotopes for medical applications
    Webster, Ben
    Ivanov, Peter
    Robinson, Andrew
    Collins, Sean
    Fenwick, Andrew
    Read, David
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2018, 61 (14): : 1119 - 1119
  • [36] MEDICAL APPLICATIONS OF SHORT-LIVED, CYCLOTRON-PRODUCED RADIONUCLIDES
    HIGHFILL, RR
    WIELAND, BW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2220 - 2223
  • [37] CYCLOTRON-PRODUCED TM-167 FOR BONE AND TUMOR SCANNING
    YANO, Y
    CHU, P
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1975, 2 (03): : 135 - &
  • [38] REACTIONS OF U-238 WITH CYCLOTRON-PRODUCED NITROGEN IONS
    GHIORSO, A
    ROSSI, GB
    HARVEY, BG
    THOMPSON, SG
    PHYSICAL REVIEW, 1954, 93 (01): : 257 - 257
  • [39] MESONS PRODUCED BY NEUTRONS FROM THE CYCLOTRON
    SMITH, FM
    GARDNER, E
    BRADNER, H
    PHYSICAL REVIEW, 1950, 77 (04): : 562 - 564
  • [40] CELLULAR STUDIES WITH CYCLOTRON PRODUCED NEUTRONS
    HALL, EJ
    ROSSI, HH
    RADIATION RESEARCH, 1975, 62 (03) : 554 - 554