Cyclotron-produced neutrons measurements using chlorine activation

被引:2
|
作者
Walg, Jonathan [1 ]
Feldman, Jon [2 ]
Azarzar, Amiram [3 ]
Mishani, Eyal [3 ]
Orion, Itzhak [1 ]
机构
[1] Ben Gurion Univ Negev, Dept Nucl Engn, Beer Sheva, Israel
[2] Hadassah Univ Hosp, Sharett Inst Oncol, Jerusalem, Israel
[3] SRY Med Serv, Jerusalem, Israel
关键词
PGNA; KCl; Radiation; Exposure; Gamma;
D O I
10.1016/j.nimb.2021.07.001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Certain proton reactions emit fast neutrons, and this study examines the feasibility of measuring the neutrons emitted from a typical medical 18 MeV proton cyclotron using prompt gamma neutron activation on chlorine. This neutron detection method, employed by previous studies, has been deemed successful and highly promising. The measurement system includes a gamma radiation scintillator, for example NaI(Tl), with a spectrometry setup facing a convertor that contains a chlorine solution or compounds thereof. In its natural state, elemental chlorine is a chemically unstable gas, making its use as a convertor challenging. Therefore, chlorine is usually dissolved in solutions. Such solutions are diluted with water and contain hydrogen atoms that interact intensively with the neutrons and may interrupt their detection. Accordingly, in this study, a 25.5 L container of KCl powder was placed in front of a NaI(Tl) (7.62 cm diameter by 7.62 cm length) spectrometer near a cyclotron facility. The gamma radiation spectroscopy allowed the identification of the chlorine INS gamma line at 788 keV, alongside the K-40 gamma peak. In addition, it was possible to detect the fast neutrons using a total-counting mode, when the INS counts appear above the K-40 counting level. The chlorine INS peak in the KCl convertor was detected simultaneously during the cyclotron operations and provided a direct indication of neutron exposure around the cyclotron. We conclude that using KCl as a converter, with a NaI(Tl) gamma rays counter, is successful in detecting cyclotron-produced neutron emissions.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] CYCLOTRON-PRODUCED ISOTOPES IN CLINICAL AND EXPERIMENTAL MEDICINE
    TUCKER, WD
    BRITISH JOURNAL OF RADIOLOGY, 1960, 33 (388): : 269 - 269
  • [22] CYCLOTRON-PRODUCED ISOTOPES IN CLINICAL AND EXPERIMENTAL MEDICINE
    NEWBERRY, GR
    BRITISH JOURNAL OF RADIOLOGY, 1959, 32 (382): : 633 - 641
  • [23] EFFECT OF NIRS CYCLOTRON-PRODUCED NEUTRONS ON HEMATOPOIETIC STEM-CELLS - OER AND RADIOSENSITIZING EFFECT OF MISONIDAZOLE
    KOJIMA, E
    UEKUSA, T
    OHARA, H
    JOURNAL OF RADIATION RESEARCH, 1985, 26 (01) : 25 - 25
  • [24] The study of Pt depth profile in semiconductors using cyclotron-produced radioisotopes
    Yagi, T
    Nagano, A
    Nishihara, Y
    Shimizu, T
    JOURNAL OF CRYSTAL GROWTH, 2000, 210 (1-3) : 132 - 136
  • [25] DOSIMETRY STUDIES OF CYCLOTRON-PRODUCED NEUTRON BEAMS
    PINKERTO.A
    MAMACOS, J
    LAUGHLIN, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 142 - &
  • [26] CYCLOTRON-PRODUCED ISOTOPES IN CLINICAL AND EXPERIMENTAL MEDICINE
    NEWBERY, GR
    BRITISH JOURNAL OF RADIOLOGY, 1959, 32 (374): : 96 - 96
  • [27] Imaging study of using radiopharmaceuticals labeled with cyclotron-produced 99mTc
    Hou, X.
    Tanguay, J.
    Vuckovic, M.
    Buckley, K.
    Schaffer, P.
    Benard, F.
    Ruth, T. J.
    Celler, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23): : 8199 - 8213
  • [28] QUALITY OF CYCLOTRON PRODUCED NEUTRONS
    SCHULTZ, JN
    GLASS, WA
    HEALTH PHYSICS, 1967, 13 (11): : 1237 - +
  • [29] Quality assessment of cyclotron-produced 67Cu
    Bruhlmann, Santiago
    Walther, Martin
    Kreller, Martin
    Pietzsch, Hans-Jurgen
    Kniess, Torsten
    Kopka, Klaus
    NUCLEAR MEDICINE AND BIOLOGY, 2022, 114 : S42 - S42
  • [30] A MICRODOSIMETRIC CHARACTERIZATION OF A CYCLOTRON-PRODUCED THERAPEUTIC NEUTRON BEAM
    STAFFORD, PM
    HORTON, JL
    ALMOND, PR
    MEDICAL PHYSICS, 1987, 14 (06) : 1015 - 1019