Comparing greenhouse natural ventilation to fan and pad cooling

被引:4
|
作者
Teitel, M. [1 ]
Barak, M. [1 ]
Tanny, J.
Cohen, S.
Ben-Yaakov, E. [1 ]
Gatker, J. [1 ]
机构
[1] Agr Res Org, Inst Agr Engn, Volcani Ctr, IL-50250 Bet Dagan, Israel
关键词
microcluriate; roses; protected cultivation;
D O I
10.17660/ActaHortic.2007.761.2
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Greenhouse growers and designers are repeatedly forced to choose between installations of natural ventilation (NV) or expensive fans with evaporative cooling (FV). The known advantages and disadvantages of each system do not presently allow a clear choice. To explore the effects on microclimate and crop, and to determine the limits of each system, experiments were done simultaneously in two adjacent compartments of similar area and orientation in which roses were grown; one naturally and the other mechanically ventilated with evaporative cooling. Three ventilation modes were studied in the naturally ventilated compartment: roof openings, side openings, and a combination of roof and side openings. Two fans capable of delivering a maximum ventilation rate of 0.06 m(3) s(-1) m(-2) were used in the FV compartment. Consumption of electricity by the fans was monitored continuously as were micro-meteorological parameters in both compartments, e.g., wet and dry bulb air temperatures, leaf temperatures, radiation and soil heat flux. Yield (number of stems), stem length, bud diameter and length, leaf area index (LAI) and transpiration rate were measured to allow comparison between the treatments. In summer, the average air temperature, during the hottest hours of the day, between 10-14 h was higher in the NV house (31.8 degrees C) than in the FV house (26.8 degrees C), as expected. In addition, the humidity ratio, leaf temperature, transpiration rate and yield were higher in the NV house. Yield in the NV compartment was about 26-46% higher. However, the average stem length was larger in FV (43.4 cm) than in NV (38.7 cm). Relative humidity and LAI were lower in the NV than in the FV house. Small, however, significant differences between compartments were observed with regard to average bud diameter and length. During the hot days of the summer, plants in the FV house appeared to be more robust than in the NV house.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [41] Fan and Pad Evaporative Cooling System for Greenhouses: Evaluation of a Numerical and Analytical Model
    Sapounas, A. A.
    Nikita-Martzopoulou, Ch.
    Bartzanas, T.
    Kittas, C.
    PROCEEDINGS OF THE INTERNATIONAL WORKSHOP ON GREENHOUSE ENVIRONMENTAL CONTROL AND CROP PRODUCTION IN SEMI-ARID REGIONS, 2008, (797): : 131 - +
  • [42] Cooling Wet-Pad Fan Control System of Piggery Based on Zigbee
    Wang, Runtao
    Yang, Fang
    Li, Ming
    Tian, Lei
    Zhang, Yu
    COMPUTER AND COMPUTING TECHNOLOGIES IN AGRICULTURE V, PT I, 2012, 368 : 147 - +
  • [43] Effect of newly developed fan and mist evaporative cooling system on greenhouse cooling and growth of cucumber
    Nam, Y. I.
    Yu, I. H.
    Kim, T. Y.
    Roh, M. Y.
    Cho, M. W.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON ADVANCES IN ENVIRONMENTAL CONTROL, AUTOMATION AND CULTIVATION SYSTEMS FOR SUSTAINABLE, HIGH-QUALITY CROP PRODUCTION UNDER PROTECTED CULTIVATION, 2007, (761): : 49 - 53
  • [44] The effects of pad and fan Evaporating Cooling System on pepper plants and fruit disorders
    Bar-Tal, Asher
    Aloni, Benny
    Arbel, Abraham
    Barak, Mordechai
    Karni, Leah
    Oserovitz, Johnatan
    Hazan, Amram
    Gantz, Sheli
    Avidan, Albert
    Posalski, Itzhak
    Keinan, Miryam
    Innovation and Development of Urban Agricultural Engineering, 2005, : 337 - 345
  • [45] Solar photovoltaic-powered ventilation and cooling system of a greenhouse
    Sharma, P. K.
    Samuel, D. V. K.
    CURRENT SCIENCE, 2014, 106 (03): : 362 - 364
  • [46] Solar photovoltaic-powered ventilation and cooling system of a greenhouse
    Sharma, P.K. (pks_ageg@iari.res.in), 1600, Indian Academy of Sciences (106):
  • [47] Greenhouse natural ventilation modelling: a survey of the different approaches
    Boulard, T.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON GREENHOUSE COOLING, 2006, (719): : 29 - 40
  • [48] Comparison of four natural ventilation systems in a Mediterranean greenhouse
    Coelho, M.
    Baptista, F.
    da Cruz, V. Fitas
    Garcia, J. L.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON GREENHOUSE COOLING, 2006, (719): : 157 - +
  • [49] THE EFFECT OF BENCH ARRANGEMENTS ON THE NATURAL VENTILATION OF A MULTISPAN GREENHOUSE
    Kruger, Sunita
    Pretorius, Leon
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 8A, 2014,
  • [50] Natural ventilation performance of six greenhouse and tunnel types
    Boulard, T
    Feuilloley, P
    Kittas, C
    JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1997, 67 (04): : 249 - 266