Comparing greenhouse natural ventilation to fan and pad cooling

被引:4
|
作者
Teitel, M. [1 ]
Barak, M. [1 ]
Tanny, J.
Cohen, S.
Ben-Yaakov, E. [1 ]
Gatker, J. [1 ]
机构
[1] Agr Res Org, Inst Agr Engn, Volcani Ctr, IL-50250 Bet Dagan, Israel
关键词
microcluriate; roses; protected cultivation;
D O I
10.17660/ActaHortic.2007.761.2
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Greenhouse growers and designers are repeatedly forced to choose between installations of natural ventilation (NV) or expensive fans with evaporative cooling (FV). The known advantages and disadvantages of each system do not presently allow a clear choice. To explore the effects on microclimate and crop, and to determine the limits of each system, experiments were done simultaneously in two adjacent compartments of similar area and orientation in which roses were grown; one naturally and the other mechanically ventilated with evaporative cooling. Three ventilation modes were studied in the naturally ventilated compartment: roof openings, side openings, and a combination of roof and side openings. Two fans capable of delivering a maximum ventilation rate of 0.06 m(3) s(-1) m(-2) were used in the FV compartment. Consumption of electricity by the fans was monitored continuously as were micro-meteorological parameters in both compartments, e.g., wet and dry bulb air temperatures, leaf temperatures, radiation and soil heat flux. Yield (number of stems), stem length, bud diameter and length, leaf area index (LAI) and transpiration rate were measured to allow comparison between the treatments. In summer, the average air temperature, during the hottest hours of the day, between 10-14 h was higher in the NV house (31.8 degrees C) than in the FV house (26.8 degrees C), as expected. In addition, the humidity ratio, leaf temperature, transpiration rate and yield were higher in the NV house. Yield in the NV compartment was about 26-46% higher. However, the average stem length was larger in FV (43.4 cm) than in NV (38.7 cm). Relative humidity and LAI were lower in the NV than in the FV house. Small, however, significant differences between compartments were observed with regard to average bud diameter and length. During the hot days of the summer, plants in the FV house appeared to be more robust than in the NV house.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [21] Selection of a computational fluid dynamics (CFD) model and its application to greenhouse pad-fan cooling (PFC) systems
    Xu, Feng-ying
    Lu, Hong-fang
    Chen, Zhen
    Guan, Zhi-cong
    Chen, Yi-wei
    Shen, Guo-wei
    Jiang, Zhuo
    JOURNAL OF CLEANER PRODUCTION, 2021, 302
  • [22] Fan ventilated greenhouse cooling: Some considerations for design
    Willits, D. H.
    Proceedings of the International Symposium on Greenhouse Cooling, 2006, (719): : 83 - 95
  • [23] The role of transpirational cooling in the design of greenhouse ventilation
    Seginer, I
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON DESIGN AND ENVIRONMENTAL CONTROL OF TROPICAL AND SUBTROPICAL GREENHOUSES, 2002, (578): : 55 - 61
  • [24] Microclimate and cucumber crop transpiration in a greenhouse cooled by pad and fan system
    Katsoulas, N.
    Nikolaou, G.
    Neocleous, D.
    Kittas, C.
    XXX INTERNATIONAL HORTICULTURAL CONGRESS IHC2018: III INTERNATIONAL SYMPOSIUM ON INNOVATION AND NEW TECHNOLOGIES IN PROTECTED CULTIVATION, 2020, 1271 : 235 - 239
  • [25] Climate Distribution in a Fan and Pad Evaporative Cooled Greenhouse: a CFD Approach
    Bartzanas, T.
    Fidaros, D.
    Baxevanou, C.
    Kittas, C.
    IST INTERNATIONAL SYMPOSIUM ON CFD APPLICATIONS IN AGRICULTURE, 2013, 1008 : 185 - 190
  • [26] Natural ventilation of a greenhouse with top screen
    Nielsen, OF
    BIOSYSTEMS ENGINEERING, 2002, 81 (04) : 443 - 451
  • [27] Greenhouse natural ventilation by wind forces
    Haxaire, R
    Boulard, T
    Mermier, M
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE AND BRITISH-ISRAELI WORKSHOP ON GREENHOUSE TECHNIQUES TOWARDS THE 3RD MILLENNIUM, 2000, (534): : 31 - 40
  • [28] FAN VENTILATION VS EVAPORATIVE COOLING FOR BROILER HENS
    ANDREWS, LD
    STAMPS, L
    ARKANSAS FARM RESEARCH, 1985, 34 (05): : 4 - 4
  • [29] CFD Simulation Study on the Cooling Characteristics of Shading and Natural Ventilation in Greenhouse of a Botanical Garden in Shanghai
    Shi, Jianhong
    Wang, Haidong
    Wang, Jianan
    SUSTAINABILITY, 2023, 15 (04)
  • [30] Effect of natural ventilation rate on relative humidity and water use for fog cooling in a semiarid greenhouse
    Sase, S.
    Ishii, M.
    Moriyama, H.
    Kubota, C.
    Kurata, K.
    Hayashi, M.
    Sabeh, N.
    Romero, P.
    Giacomelli, G. A.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON GREENHOUSE COOLING, 2006, (719): : 385 - +