Comparing greenhouse natural ventilation to fan and pad cooling

被引:4
|
作者
Teitel, M. [1 ]
Barak, M. [1 ]
Tanny, J.
Cohen, S.
Ben-Yaakov, E. [1 ]
Gatker, J. [1 ]
机构
[1] Agr Res Org, Inst Agr Engn, Volcani Ctr, IL-50250 Bet Dagan, Israel
关键词
microcluriate; roses; protected cultivation;
D O I
10.17660/ActaHortic.2007.761.2
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Greenhouse growers and designers are repeatedly forced to choose between installations of natural ventilation (NV) or expensive fans with evaporative cooling (FV). The known advantages and disadvantages of each system do not presently allow a clear choice. To explore the effects on microclimate and crop, and to determine the limits of each system, experiments were done simultaneously in two adjacent compartments of similar area and orientation in which roses were grown; one naturally and the other mechanically ventilated with evaporative cooling. Three ventilation modes were studied in the naturally ventilated compartment: roof openings, side openings, and a combination of roof and side openings. Two fans capable of delivering a maximum ventilation rate of 0.06 m(3) s(-1) m(-2) were used in the FV compartment. Consumption of electricity by the fans was monitored continuously as were micro-meteorological parameters in both compartments, e.g., wet and dry bulb air temperatures, leaf temperatures, radiation and soil heat flux. Yield (number of stems), stem length, bud diameter and length, leaf area index (LAI) and transpiration rate were measured to allow comparison between the treatments. In summer, the average air temperature, during the hottest hours of the day, between 10-14 h was higher in the NV house (31.8 degrees C) than in the FV house (26.8 degrees C), as expected. In addition, the humidity ratio, leaf temperature, transpiration rate and yield were higher in the NV house. Yield in the NV compartment was about 26-46% higher. However, the average stem length was larger in FV (43.4 cm) than in NV (38.7 cm). Relative humidity and LAI were lower in the NV than in the FV house. Small, however, significant differences between compartments were observed with regard to average bud diameter and length. During the hot days of the summer, plants in the FV house appeared to be more robust than in the NV house.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [1] GREENHOUSE COOLING WITH A POSITIVE PRESSURE PAD-AND-FAN SYSTEM
    ZIESLIN, N
    GAZIT, M
    GARTENBAUWISSENSCHAFT, 1978, 43 (04): : 185 - 187
  • [2] Assessing the variable performance of fan-and-pad cooling in a subtropical desert greenhouse
    Saberian, Ayad
    Sajadiye, Seyed Majid
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [3] The efficiency of fan-pad cooling system in greenhouse and building up of internal greenhouse temperature map
    Oz, Hasan
    Atilgan, Atilgan
    Buyuktas, Kenan
    Alagoz, Taner
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2009, 8 (20): : 5436 - 5444
  • [4] The Analysis of Cooling Time and Energy Consumption of VAV Fan-pad Evaporative Cooling Systems in a Greenhouse
    Zeng, Zhixiong
    Guo, Jiaming
    Wei, Xinyu
    Lu, Enli
    Liu, Yanhua
    HORTSCIENCE, 2020, 55 (06) : 812 - 818
  • [5] Numerical and Experimental Study of Fan and Pad Evaporative Cooling System in a Greenhouse with Tomato Crop
    Sapounas, A. A.
    Nikita-Martzopoulou, Ch.
    Martzopoulos, G.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON HIGH TECHNOLOGY FOR GREENHOUSE SYSTEM MANAGEMENT, VOLS 1 AND 2, 2008, (801): : 987 - 994
  • [6] Water use for pad and fan evaporative cooling of a greenhouse in a semi-arid climate
    Sabeh, N. C.
    Giacomelli, G. A.
    Kubota, C.
    Proceedings of the International Symposium on Greenhouse Cooling, 2006, (719): : 409 - 416
  • [7] Numerical simulation of fan and pad evaporative cooling system of an experimental greenhouse with tomato crop
    Sapounas, A.
    Nikita-Martzopoulou, Ch.
    Bartzanas, Th.
    Kittas, C.
    ACTUAL TASKS ON AGRICULTURAL ENGINEERING, 2007, 35 : 489 - +
  • [8] Analysis and Optimization of the Fan-Pad Evaporative Cooling System for Greenhouse Based on CFD
    Chen, Jiaoliao
    Cai, Yanwen
    Xu, Fang
    Hu, Haigen
    Ai, Qinglin
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [9] Performance of positive pressure fan-pad cooling system and cooling load model for Chinese solar greenhouse
    Sun W.
    Zhou B.
    Xu F.
    Shang C.
    Lu C.
    Guo W.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2019, 35 (16): : 214 - 224
  • [10] Simulated performance of a greenhouse cooling control strategy with natural ventilation and fog cooling
    Villarreal-Guerrero, Federico
    Kacira, Murat
    Fitz-Rodriguez, Efren
    Linker, Raphael
    Kubota, Chieri
    Giacomelli, Gene A.
    Arbel, Avraham
    BIOSYSTEMS ENGINEERING, 2012, 111 (02) : 217 - 228