Deep-learning image-reconstruction algorithm for dual-energy CT angiography with reduced iodine dose: preliminary results

被引:16
|
作者
Noda, Y. [1 ]
Nakamura, F. [1 ]
Kawamura, T. [1 ]
Kawai, N. [1 ]
Kaga, T. [1 ]
Miyoshi, T. [2 ]
Kato, H. [1 ]
Hyodo, F. [3 ]
Matsuo, M. [1 ]
机构
[1] Gifu Univ, Dept Radiol, 1-1 Yanagido, Gifu 5011194, Japan
[2] Gifu Univ Hosp, Dept Radiol Serv, 1-1 Yanagido, Gifu 5011194, Japan
[3] Gifu Univ, Dept Radiol, Frontier Sci Imaging, 1-1 Yanagido, Gifu 5011194, Japan
关键词
COMPUTED-TOMOGRAPHY; AORTIC-ANEURYSM; REPAIR; ENDOLEAKS; QUALITY;
D O I
10.1016/j.crad.2021.10.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the computed tomography (CT) attenuation values, background noise, arterial depiction, and image quality in whole-body dual-energy CT angiography (DECTA) at 40 keV with a reduced iodine dose using deep-learning image reconstruction (DLIR) and compare them with hybrid iterative reconstruction (IR). MATERIAL AND METHODS: Whole-body DECTA with a reduced iodine dose (200 mg iodine/ kg) was performed in 22 patients, and DECTA data at 1.25-mm section thickness with 50% overlap were reconstructed at 40 keV using 40% adaptive statistical iterative reconstruction with Veo (hybrid-IR group), and DLIR at medium and high levels (DLIR-M and DLIR-H groups). The CT attenuation values of the thoracic and abdominal aortas and iliac artery and background noise were measured. Arterial depiction and image quality on axial, multiplanar reformatted (MPR), and volume-rendered (VR) images were assessed by two readers. Quantitative and qualitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H groups. RESULTS: The vascular CT attenuation values were almost comparable between the three groups (p=0.013-0.97), but the background noise was significantly lower in the DLIR-H group than in the hybrid-IR and DLIR-M groups (p<0.001). The arterial depictions on axial and MPR images and in almost all arteries on VR images were comparable (p=0.14-1). The image quality of axial, MPR, and VR images was significantly better in the DLIR-H group (p<0.001 -0.015). CONCLUSION: DLIR significantly reduced background noise and improved image quality in DECTA at 40 keV compared with hybrid-IR, while maintaining the arterial depiction in almost all arteries. (c) 2021 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E138 / E146
页数:9
相关论文
共 50 条
  • [21] Dual-energy CT Aortography with 50% Reduced Iodine Dose, Versus Single-energy CT Aortography with Standard Iodine Dose
    Shuman, William P.
    Chan, Keith T.
    Busey, Janet M.
    Mitsumori, Lee M.
    Koprowicz, Kent M.
    ACADEMIC RADIOLOGY, 2016, 23 (05) : 611 - 618
  • [22] Dual-Energy CT Urography With 50% Reduced Iodine Dose Versus Single-Energy CT Urography With Standard Iodine Dose
    Shuman, William P.
    Mileto, Achille
    Busey, Janet M.
    Desai, Nitin
    Koprowicz, Kent M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (01) : 117 - 123
  • [23] Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study
    Joël Greffier
    Quentin Durand
    Julien Frandon
    Salim Si-Mohamed
    Maeliss Loisy
    Fabien de Oliveira
    Jean-Paul Beregi
    Djamel Dabli
    European Radiology, 2023, 33 : 699 - 710
  • [24] Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction
    Noda, Yoshifumi
    Nakamura, Fumihiko
    Yasuda, Noriyuki
    Miyoshi, Toshiharu
    Kawai, Nobuyuki
    Kawada, Hiroshi
    Hyodo, Fuminori
    Matsuo, Masayuki
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1121):
  • [25] Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study
    Greffier, Joel
    Durand, Quentin
    Frandon, Julien
    Si-Mohamed, Salim
    Loisy, Maeliss
    de Oliveira, Fabien
    Beregi, Jean-Paul
    Dabli, Djamel
    EUROPEAN RADIOLOGY, 2023, 33 (01) : 699 - 710
  • [26] A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography
    Wang, Mengzhen
    Fan, Jing
    Shi, Xiaofeng
    Qin, Le
    Yan, Fuhua
    Yang, Wenjie
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 146
  • [27] A cascaded deep-learning reconstruction method for sparse-view kV-switching dual-energy CT
    Zhang, Ruoqiao
    Zhou, Jian
    Yu, Zhou
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [28] Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen
    Sato, Mineka
    Ichikawa, Yasutaka
    Domae, Kensuke
    Yoshikawa, Kazuya
    Kanii, Yoshinori
    Yamazaki, Akio
    Nagasawa, Naoki
    Nagata, Motonori
    Ishida, Masaki
    Sakuma, Hajime
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5499 - 5507
  • [29] Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography
    Dominik C. Benz
    Sara Ersözlü
    François L. A. Mojon
    Michael Messerli
    Anna K. Mitulla
    Domenico Ciancone
    David Kenkel
    Jan A. Schaab
    Catherine Gebhard
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    Ronny R. Buechel
    European Radiology, 2022, 32 : 2620 - 2628
  • [30] Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography
    Benz, Dominik C.
    Ersoezlue, Sara
    Mojon, Francois L. A.
    Messerli, Michael
    Mitulla, Anna K.
    Ciancone, Domenico
    Kenkel, David
    Schaab, Jan A.
    Gebhard, Catherine
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2620 - 2628