Numerical characterisation of the transient eletromagnetic field generated in a gas insulated substation during the operation of a disconnector switch or a circuit breaker is essential when sensitive control devices using VLSI circuits are being used in modern gas insulated substations. The quantification of emission levels from the gas insulated equipment during switching events is found to be important for the EMC design of control devices operating in such harsh EM environment and hence to ensure reliable operation of the systems. In the present study, transient electromagnetic field em fission from gas to air bushing through the silicon rubber ins alated housing has been quantified for Very Fast Transient Currents (VFTC) which are generated during switching events in a 245 kV GIS. For this purpose, the modified version of Finite Difference Time Domain (FDTD) technique has been adopted. For the estimation of transient field emission levels, a computational model has bean developed for the 245 kV gas to air bushing. The variation of EM field pattern along the axis of the bushing at various radial distances is plotted and the effect of parameters like frequency of transient current, physical positioning of the bushing above the ground plane etc., on emission levels is analysed as a part of the present study. The range of enhancement factors of the transient field levels due to the presence of a metallic structure on the ground plane, which simulates the control cubicle in a GIS is established. Finally, the transient EM field emission levels from the gas to air bushing for the VFTC waveform calculated at the entrance of the bushing are evaluated.
引用
收藏
页码:743 / 748
页数:6
相关论文
共 50 条
  • [41] Comparison of the performance of a high voltage generator insulated by gas or liquid dielectric
    Antonini, P.
    Borsato, E.
    Carugno, G.
    Dal Corso, F.
    Facco, A.
    Fanin, C.
    Gallo, C. S.
    Galata, A.
    Gobbo, R.
    La Torre, L.
    Montecassiano, F.
    Pegoraro, M.
    Poggi, M.
    Zotto, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (07):
  • [42] OSCILLATING SWITCHING IMPULSE VOLTAGE FOR HIGH-VOLTAGE TESTS ON SF6-INSULATED SYSTEMS
    CRUCIUS, M
    DIESSNER, A
    LUXA, G
    ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1977, 98 (02): : 132 - 136
  • [43] Analysis of PD spectrums in high voltage apparatus insulated with compressed gas
    Zheng, DC
    Zhang, CX
    Yu, CS
    Liu, HW
    Yang, JX
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 585 - 588
  • [44] Technology progress in high-voltage gas-insulated substations
    Metwally I.A.
    IEEE Potentials, 2010, 29 (06): : 25 - 32
  • [45] Investigation on Dielectric Failure of High Voltage Equipment in Substation Caused by Capacitor Bank Switching
    Warunee Srisongkram
    Phanupong Fuangpian
    Thanapong Suwanasri
    Cattareeya Suwanasri
    Journal of Electrical Engineering & Technology, 2019, 14 : 849 - 860
  • [46] Investigation on Dielectric Failure of High Voltage Equipment in Substation Caused by Capacitor Bank Switching
    Srisongkram, Warunee
    Fuangpian, Phanupong
    Suwanasri, Thanapong
    Suwanasri, Cattareeya
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2019, 14 (02) : 849 - 860
  • [47] Partial Discharge Measurements in a High Voltage Gas Insulated Transmission Line Insulated with CO2
    Widger, Phillip
    Carr, Daniel
    Reid, Alistair
    Hills, Meirion
    Stone, Chris
    Haddad, A.
    ENERGIES, 2020, 13 (11)
  • [49] Development of the measuring device of transient enclosure voltage in ultra high voltage gas insulated switchgear
    State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Changping District, Beijing
    102206, China
    不详
    100031, China
    不详
    100192, China
    Zhongguo Dianji Gongcheng Xuebao, 23 (6235-6245):
  • [50] A calculation method of transient field under very fast transient over-voltage in gas insulated substation (GIS)
    Gao, YH
    Yuan, H
    Wang, EZ
    Cao, YD
    APPLIED ELECTROMAGNETICS (III), 2001, 10 : 215 - 218