Repeatability and comparison of clinical techniques for anterior chamber angle assessment

被引:31
|
作者
Campbell, Peter [1 ,2 ,3 ]
Redmond, Tony [2 ,4 ]
Agarwal, Rishi [2 ,3 ]
Marshall, Lewis R. [5 ]
Evans, Bruce J. W. [2 ,3 ,5 ]
机构
[1] St Thomas Hosp, Ophthalmol, London, England
[2] Neville Chappell Res Clin, Inst Optometry, London, England
[3] London S Bank Univ, Fac Hlth & Social Care, London, England
[4] Cardiff Univ, Sch Optometry & Vis Sci, Cardiff CF10 3AX, S Glam, Wales
[5] Cole Martin Tregaskis Optometrists, Brentwood, Essex, England
关键词
anterior chamber; anterior segment; anterior segment optical coherence tomography; Gonioscopy; imaging; Van Herick; OPTICAL COHERENCE TOMOGRAPHY; CLOSURE GLAUCOMA; UK OPTOMETRISTS; NARROW ANGLES; SEGMENT; POPULATION; GONIOSCOPY; AGREEMENT;
D O I
10.1111/opo.12200
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo assess the repeatability of gonioscopy, van Herick method and anterior segment Optical Coherence Tomography (AS-OCT) and determine the agreement between these techniques within a community optometry setting. MethodsGonioscopy, van Herick method and AS-OCT imaging were performed by an optometrist on two occasions, 1month apart, on 80 subjects aged over 40years recruited from community optometry practices. Anterior segment images were captured with a spectral domain OCT (Topcon 3D OCT-2000; wavelength 840nm) set to the Anterior Segment (AS) mode. Eyes were graded as open or occludable for each method. AS-OCT images from both visits were graded by a second optometrist masked to the gonioscopy and van Herick method results, and the visit on which the images were acquired. Cohen's kappa () was used to describe the intra-observer repeatability. Likelihood ratios, sensitivity and specificity of van Herick method and AS-OCT were calculated, using gonioscopy as the reference standard. ResultsMeasurements were obtained from 80 eyes of 80 subjects. In four cases, AS-OCT images were un-gradable due to difficulty in locating the scleral spur. The repeatability of gonioscopy was fair =0.29, while that of the van Herick method (=0.54) and AS-OCT (=0.47) were somewhat better. The van Herick method showed good sensitivity (visit 1: 75%, visit 2: 69%) and high specificity (visit 1: 88%, visit 2: 96%). The sensitivity of AS-OCT was fair (visit 1: 46%, visit 2: 25%), but specificity was high (visit 1: 87%. visit 2: 89%). ConclusionIntra-observer repeatability was better for van Herick method and for AS-OCT than for gonioscopy, despite the latter being considered the gold standard method. The van Herick method appeared to be more sensitive than AS-OCT when identifying eyes at risk of angle closure. A standalone anterior segment OCT with a longer wavelength laser could afford better visualisation of the angle, and might therefore be expected to enable the examiner to make more precise classifications. These instruments are not widely used by optometrists in clinical practice in the UK at present.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 50 条
  • [41] Clinical anatomy of the anterior chamber angle in congenital aniridia and consequences for trabeculotomy/cyclophotocoagulation
    Viestenz, Arne
    Seitz, Berthold
    Deland, Eva
    Fiorentzis, Miltiadis
    Latta, Lorenz
    Viestenz, Anja
    Kaesmann-Kellner, Barbara
    [J]. CLINICAL ANATOMY, 2018, 31 (01) : 64 - 67
  • [42] Distribution and Determinants of Anterior Chamber Angle and Anterior Chamber Volume in Young Chinese Adults
    Li, Dan-Lin
    Qin, Yu
    Zheng, Ya-Jie
    Yin, Zhi-Jian
    Li, Yue-Zu
    Ma, Rong
    Liang, Gang
    Pan, Chen-Wei
    [J]. OPHTHALMIC EPIDEMIOLOGY, 2024,
  • [43] Novel approach for anterior chamber angle analysis - Anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA)
    Leung, Christopher Kai-shun
    Yung, Wing-ho
    Yiu, Cedric Ka-fai
    Lam, Sze-wing
    Leung, Dexter Yu-lung
    Tse, Raymond Kwok-kay
    Tham, Clement Chi-yung
    Chan, Wai-man
    Lam, Dennis Shun-chiu
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (10) : 1395 - 1401
  • [45] Assessment of anterior chamber angle changes after phacoemulsification with swept-source OCT
    Qian Zheng
    Man Hu
    Zhang-Liang Li
    Ping-Jun Chang
    Yun-E Zhao
    [J]. International Journal of Ophthalmology, 2021, (10) : 1527 - 1532
  • [46] A Deep Learning Systemfor Automatic Assessment of Anterior Chamber Angle in Ultrasound Biomicroscopy Images
    Wang, Wensai
    Wang, Lingxiao
    Wang, Xiaochun
    Zhou, Sheng
    Lin, Song
    Yang, Jun
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (11):
  • [47] Assessment of anterior chamber angle changes after phacoemulsification with swept-source OCT
    Zheng, Qian
    Hu, Man
    Li, Zhang-Liang
    Chang, Ping-Jun
    Zhao, Yun-E
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (10) : 1527 - 1532
  • [48] Recent advances in anterior chamber angle imaging
    Natalia Porporato
    Mani Baskaran
    Rahat Husain
    Tin Aung
    [J]. Eye, 2020, 34 : 51 - 59
  • [49] Biometric gonioscopy for measuring the anterior chamber angle
    Thomas, R
    [J]. OPHTHALMOLOGY, 2001, 108 (03) : 423 - 425
  • [50] Radial ciliary vessel in the angle of anterior chamber
    Chandran, Premanand
    Arora, Ekta
    Sahu, Abhipsa