Integrated sample-to-detection chip for nucleic acid test assays

被引:10
|
作者
Prakash, R. [1 ]
Pabbaraju, K. [1 ]
Wong, S. [1 ]
Tellier, R. [1 ,2 ]
Kaler, K. V. I. S. [3 ]
机构
[1] Prov Lab Publ Hlth Alberta, 3030 Hosp Dr NW, Calgary, AB T2N 4W4, Canada
[2] Univ Calgary, Cumming Sch Med, Dept Microbiol Immunol & Infect Dis, 3330 Hosp Dr NW, Calgary, AB T2N 4N1, Canada
[3] Univ Calgary, Dept Elect & Comp Engn, 2500 Univ Dr NW, Calgary, AB T2N 1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Lab-on-a-chip; Nucleic acid tests; Sample-to-detection; Droplet microfluidics; Dielectrophoresis; Electrowetting; POLYMERASE-CHAIN-REACTION; REVERSE TRANSCRIPTION-PCR; LIQUID DROPLETS; DIELECTROPHORESIS; AMPLIFICATION; EXTRACTION; SEPARATION; ACTUATION; PURIFICATION; MANIPULATION;
D O I
10.1007/s10544-016-0069-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Fully integrated nucleic acid pretreatment, amplification, and detection on a paper chip for identifying EGFR mutations in lung cancer cells
    Chen, Peng
    Chen, Chen
    Liu, Yuhong
    Du, Wei
    Feng, Xiaojun
    Liu, Bi-Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 472 - 477
  • [32] Paper-based nuclease protection assay with on-chip sample pretreatment for point-of-need nucleic acid detection
    Noviana, Eka
    Jain, Sidhartha
    Hofstetter, Josephine
    Geiss, Brian J.
    Dandy, David S.
    Henry, Charles S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (13) : 3051 - 3061
  • [33] Multifunctional Sample Preparation Kit and On-Chip Quantitative Nucleic Acid Sequence-Based Amplification Tests for Microbial Detection
    Zhao, Xinyan
    Dong, Tao
    ANALYTICAL CHEMISTRY, 2012, 84 (20) : 8541 - 8548
  • [34] A highly-parallelized and low-sample-size chip for simultaneous detection of protein and nucleic acid biomarkers in hepatocellular carcinoma
    Li, Yingxue
    Xu, Qi
    Zhang, Wei
    Yang, Qi
    Guo, Zhen
    Li, Chuanyu
    Zhang, Zhiqi
    Dong, Qiongzhu
    Sun, Haoting
    Zhang, Changsong
    Li, Chao
    Yao, Jia
    Li, Jinze
    Qin, Lunxiu
    Zhou, Lianqun
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 392
  • [35] Paper-based nuclease protection assay with on-chip sample pretreatment for point-of-need nucleic acid detection
    Eka Noviana
    Sidhartha Jain
    Josephine Hofstetter
    Brian J. Geiss
    David S. Dandy
    Charles S. Henry
    Analytical and Bioanalytical Chemistry, 2020, 412 : 3051 - 3061
  • [36] Research on diagnostic system integrated nucleic acid extraction and detection
    Meng, Xiangkai
    Jin, Guangyong
    Wang, Zhe
    Gong, Ping
    Duanmu, Luyang
    INTERNATIONAL CONFERENCE ON OPTOELECTRONIC AND MICROELECTRONIC TECHNOLOGY AND APPLICATION, 2020, 11617
  • [37] Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat
    Kwakye, Sylvia
    Goral, Vasily N.
    Baeumner, Antje J.
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (12): : 2217 - 2223
  • [38] Quantum dot-mediated biosensing assays for specific nucleic acid detection
    Yeh, Hsin-Chih
    Ho, Yi-Ping
    Wang, Tza-Huei
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2005, 1 (02) : 115 - 121
  • [39] Invasive action -: Third Wave Technologies' Invader™ assays for nucleic acid detection
    Wilkinson, DA
    SCIENTIST, 1999, 13 (22): : 16 - 16
  • [40] Engineering a Rigid Nucleic Acid Structure to Improve the Limit of Detection for Genetic Assays
    Malekjahani, Ayden
    Lekuti, Ayokunle A.
    Valiente, Pedro A.
    Osborne, Matthew
    Li, Vanessa Y. C.
    Kim, Philip M.
    Chan, Warren C. W.
    ANALYTICAL CHEMISTRY, 2024, 96 (23) : 9729 - 9736