Paper-based nuclease protection assay with on-chip sample pretreatment for point-of-need nucleic acid detection

被引:14
|
作者
Noviana, Eka [1 ,2 ]
Jain, Sidhartha [3 ]
Hofstetter, Josephine [4 ]
Geiss, Brian J. [3 ,5 ]
Dandy, David S. [3 ,6 ]
Henry, Charles S. [1 ,3 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
[2] Univ Gadjah Mada, Fac Pharm, Dept Pharmaceut Chem, Yogyakarta 55281, Indonesia
[3] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
[4] Access Sensor Technol, Ft Collins, CO 80526 USA
[5] Colorado State Univ, Dept Microbiol Immunol & Pathol, Ft Collins, CO 80523 USA
[6] Colorado State Univ, Dept Chem & Biol Engn, Ft Collins, CO 80523 USA
基金
美国国家卫生研究院;
关键词
Nuclease protection assay; Nucleic acid detection; Paper-based device; Lateral flow assay; SENSITIVE DETECTION; RAPID DETECTION; HYBRIDIZATION; DNA; AMPLIFICATION; CHITOSAN; NANOPARTICLES; MOLECULES; VIRUS;
D O I
10.1007/s00216-020-02569-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pathogen detection is crucial for human, animal, and environmental health; crop protection; and biosafety. Current culture-based methods have long turnaround times and lack sensitivity. Nucleic acid amplification tests offer high specificity and sensitivity. However, their cost and complexity remain a significant hurdle to their applications in resource-limited settings. Thus, point-of-need molecular diagnostic platforms that can be used by minimally trained personnel are needed. The nuclease protection assay (NPA) is a nucleic acid hybridization-based technique that does not rely on amplification, can be paired with other methods to improve specificity, and has the potential to be developed into a point-of-need device. In traditional NPAs, hybridization of an anti-sense probe to the target sequence is followed by single-strand nuclease digestion. The double-stranded target-probe hybrids are protected from nuclease digestion, precipitated, and visualized using autoradiography or other methods. We have developed a paper-based nuclease protection assay (PB-NPA) that can be implemented in field settings as the detection approach requires limited equipment and technical expertise. The PB-NPA uses a lateral flow format to capture the labeled target-probe hybrids onto a nitrocellulose membrane modified with an anti-label antibody. A colorimetric enzyme-substrate pair is used for signal visualization, producing a test line. The nuclease digestion of non-target and mismatched DNA provides high specificity while signal amplification with the reporter enzyme-substrate provides high sensitivity. We have also developed an on-chip sample pretreatment step utilizing chitosan-modified paper to eliminate possible interferents from the reaction and preconcentrate nucleic acids, thereby significantly reducing the need for auxiliary equipment.
引用
收藏
页码:3051 / 3061
页数:11
相关论文
共 50 条
  • [1] Paper-based nuclease protection assay with on-chip sample pretreatment for point-of-need nucleic acid detection
    Eka Noviana
    Sidhartha Jain
    Josephine Hofstetter
    Brian J. Geiss
    David S. Dandy
    Charles S. Henry
    Analytical and Bioanalytical Chemistry, 2020, 412 : 3051 - 3061
  • [2] Paper-based analytical devices for point-of-need applications
    Lauro A. Pradela-Filho
    William B. Veloso
    Iana V. S. Arantes
    Juliana L. M. Gongoni
    Davi M. de Farias
    Diele A. G. Araujo
    Thiago R. L. C. Paixão
    Microchimica Acta, 2023, 190
  • [3] Paper-based analytical devices for point-of-need applications
    Pradela-Filho, Lauro A.
    Veloso, William B.
    Arantes, Iana V. S.
    Gongoni, Juliana L. M.
    de Farias, Davi M.
    Araujo, Diele A. G.
    Paixao, Thiago R. L. C.
    MICROCHIMICA ACTA, 2023, 190 (05)
  • [4] Paper-based nucleic acid sample preparation for point-of-care diagnostics
    Soni, Shruti
    Toley, Bhushan J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 355
  • [5] Padlock probe-based rolling circle amplification lateral flow assay for point-of-need nucleic acid detection
    Jain, Sidhartha
    Dandy, David S.
    Geiss, Brian J.
    Henry, Charles S.
    ANALYST, 2021, 146 (13) : 4340 - 4347
  • [6] Printed Paper-Based Electrochemical Sensors for Low-Cost Point-of-Need Applications
    Smith, Suzanne
    Madzivhandila, Phophi
    Ntuli, Letta
    Bezuidenhout, Petrone
    Zheng, Haitao
    Land, Kevin
    ELECTROCATALYSIS, 2019, 10 (04) : 342 - 351
  • [7] Advances in paper-based sample pretreatment for point-of-care testing
    Tang, Rui Hua
    Yang, Hui
    Choi, Jane Ru
    Gong, Yan
    Feng, Shang Sheng
    Pingguan-Murphy, Belinda
    Huang, Qing Sheng
    Shi, Jun Ling
    Mei, Qi Bing
    Xu, Feng
    CRITICAL REVIEWS IN BIOTECHNOLOGY, 2017, 37 (04) : 411 - 428
  • [8] An integrated paper-based sample-to-answer biosensor for nucleic acid testing at the point of care
    Choi, Jane Ru
    Hu, Jie
    Tang, Ruihua
    Gong, Yan
    Feng, Shangsheng
    Ren, Hui
    Wen, Ting
    Li, XiuJun
    Abas, Wan Abu Bakar Wan
    Pingguan-Murphy, Belinda
    Xu, Feng
    LAB ON A CHIP, 2016, 16 (03) : 611 - 621
  • [9] Integrated paper-based detection chip with nucleic acid extraction and amplification for automatic and sensitive pathogen detection
    Fu, Yu
    Zhou, Xiaoming
    Xing, Da
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 261 : 288 - 296
  • [10] Promise and perils of paper-based point-of-care nucleic acid detection for endemic and pandemic pathogens
    Sritong, Navaporn
    de Medeiros, Marina Sala
    Basing, Laud Anthony
    Linnes, Jacqueline C.
    LAB ON A CHIP, 2023, 23 (05) : 888 - 912