Paper-based analytical devices for point-of-need applications

被引:48
|
作者
Pradela-Filho, Lauro A. [1 ]
Veloso, William B. [1 ]
Arantes, Iana V. S. [1 ]
Gongoni, Juliana L. M. [1 ]
de Farias, Davi M. [1 ]
Araujo, Diele A. G. [1 ]
Paixao, Thiago R. L. C. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, Dept Fundamental Chem, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Paper-based analytical devices; Colorimetry; Fluorescence; Electrochemistry; Distance-based detection; Dual/combined detectors; LAB-ON-PAPER; DISTANCE-BASED DETECTION; ELECTROCHEMICAL IMMUNOSENSORS; COLORIMETRIC DETECTION; MICROFLUIDIC DEVICES; SENSITIVE DETECTION; QUANTIFICATION; GOLD; PLATFORM; FLOW;
D O I
10.1007/s00604-023-05764-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Paper-based analytical devices (PADs) are powerful platforms for point-of-need testing since they are inexpensive devices fabricated in different shapes and miniaturized sizes, ensuring better portability. Additionally, the readout and detection systems can be accomplished with portable devices, allying with the features of both systems. These devices have been introduced as promising analytical platforms to meet critical demands involving rapid, reliable, and simple testing. They have been applied to monitor species related to environmental, health, and food issues. Herein, an outline of chronological events involving PADs is first reported. This work also introduces insights into fundamental parameters to engineer new analytical platforms, including the paper type and device operation. The discussions involve the main analytical techniques used as detection systems, such as colorimetry, fluorescence, and electrochemistry. It also showed recent advances involving PADs, especially combining optical and electrochemical detection into a single device. Dual/combined detection systems can overcome individual barriers of the analytical techniques, making possible simultaneous determinations, or enhancing the devices' sensitivity and/or selectivity. In addition, this review reports on distance-based detection, which is also considered a trend in analytical chemistry. Distance-based detection offers instrument-free analyses and avoids user interpretation errors, which are outstanding features for analyses at the point of need, especially for resource-limited regions. Finally, this review provides a critical overview of the practical specifications of the recent analytical platforms involving PADs, demonstrating their challenges. Therefore, this work can be a highly useful reference for new research and innovation.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Paper-based analytical devices for point-of-need applications
    Lauro A. Pradela-Filho
    William B. Veloso
    Iana V. S. Arantes
    Juliana L. M. Gongoni
    Davi M. de Farias
    Diele A. G. Araujo
    Thiago R. L. C. Paixão
    Microchimica Acta, 2023, 190
  • [2] Printed Paper-Based Electrochemical Sensors for Low-Cost Point-of-Need Applications
    Smith, Suzanne
    Madzivhandila, Phophi
    Ntuli, Letta
    Bezuidenhout, Petrone
    Zheng, Haitao
    Land, Kevin
    ELECTROCATALYSIS, 2019, 10 (04) : 342 - 351
  • [3] Microfluidic Paper-based Analytical Devices in Clinical Applications
    Tingting Han
    Yuhang Jin
    Chunyang Geng
    Aziz ur Rehman Aziz
    Yang Zhang
    Sha Deng
    Haijun Ren
    Bo Liu
    Chromatographia, 2020, 83 : 693 - 701
  • [5] Microfluidic Paper-based Analytical Devices in Clinical Applications
    Han, Tingting
    Jin, Yuhang
    Geng, Chunyang
    Aziz, Aziz Ur Rehman
    Zhang, Yang
    Deng, Sha
    Ren, Haijun
    Liu, Bo
    CHROMATOGRAPHIA, 2020, 83 (06) : 693 - 701
  • [6] "Paper-based Analytical Devices"
    不详
    Analytical Sciences, 2017, 33 (3) : 259 - 259
  • [7] Paper-based Analytical Devices
    Hisamoto, Hideaki
    ANALYTICAL SCIENCES, 2017, 33 (07) : 753 - 753
  • [8] Paper-based analytical devices
    Citterio, Daniel
    Kaneta, Takashi
    Analytical Sciences, 2018, 34 (01) : 5 - 6
  • [9] Paper-based Analytical Devices
    Hideaki Hisamoto
    Analytical Sciences, 2017, 33 : 753 - 753
  • [10] Detection methods and applications of microfluidic paper-based analytical devices
    Fu, Lung-Ming
    Wang, Yao-Nan
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 107 : 196 - 211