Theoretical Impact of Building Facade Thickness on Daylight Metrics and Lighting Energy Demand in Buildings: A Case Study of the Tropics

被引:2
|
作者
Mangkuto, Rizki A. [1 ]
Atthaillah [2 ,3 ]
Koerniawan, Mochamad Donny [4 ]
Yuliarto, Brian [5 ]
机构
[1] Inst Teknol Bandung, Fac Ind Technol, Bldg Phys Res Grp, Jl Ganesha 10,Labtek 6, Bandung 40132, Indonesia
[2] Inst Teknol Bandung, Fac Ind Technol, Engn Phys Doctorate Program, Ganesha 10,Labtek 6, Bandung 40132, Indonesia
[3] Univ Malikussaleh, Architecture Program, Fac Engn, Jl Cot Teungku Nie, Aceh Utara 24355, Indonesia
[4] Inst Teknol Bandung, Sch Architecture Planning & Policy Dev, Bldg Technol Res Grp, Jl Ganesha 10,Labtek 9B, Bandung 40132, Indonesia
[5] Inst Teknol Bandung, Fac Ind Technol, Adv Funct Mat Res Grp, Jl Ganesha 10,Labtek 6, Bandung 40132, Indonesia
关键词
daylighting; facade thickness; overcast sky; daylight metrics; lighting energy demand; INSULATION THICKNESS; OPTIMIZATION CRITERIA; DESIGN OPTIMIZATION; DISCOMFORT GLARE; OFFICE BUILDINGS; PERFORMANCE; AVAILABILITY; STANDARD; WINDOWS; AREA;
D O I
10.3390/buildings11120656
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In daylighting design, variation of building facade thickness (f) will result in variation of the daylight opening areas, which in turn will modify the values of daylight metrics within the space. However, studies dedicated to investigating the impact of varying f on indoor daylight metrics are relatively scarce. This study, therefore, aims to assess the theoretical impact of various facade thicknesses on various daylight metrics and lighting energy demands in a reference office space. Analytical calculations are performed using an outdoor diffuse illuminance profile of a tropical city. The building facade thickness values are varied within 0-0.50 m, at window-to-wall ratios (WWR) of 25%, 50%, and 75%. Based on sensitivity analysis, it is found that variation of f yields different impacts on the observed metrics, with sDA(300/50%) being the least influenced. Among all metrics in the central calculation point, DA(300), UDI-a, and UDI-a ' yield relatively small coefficients of variation, and thus, have the lowest uncertainty with respect to f. Among all metrics for the entire room, sDA(300/50%) and sUDI-a(50%) have the lowest uncertainty, with interquartile ranges of no more than 0.4%. Overall, the contribution of this study is providing insight into the impact of facade thickness on various daylight metrics in indoor spaces, particularly in the worst-case scenario under the standard CIE overcast sky.
引用
收藏
页数:27
相关论文
共 50 条
  • [31] Impact of building automation control systems and technical building management systems on the energy performance class of residential buildings: An Italian case study
    Ippolito, M. G.
    Sanseverino, E. Riva
    Zizzo, G.
    [J]. ENERGY AND BUILDINGS, 2014, 69 : 33 - 40
  • [32] ENERGY EFFICIENT HUMAN CENTERED OFFICE LIGHTING: A CASE STUDY ON OPEN PLAN OFFICE WITH ABSENT ACCESS TO DAYLIGHT
    Aliparast, Sevda
    Onaygil, Sermin
    [J]. LIGHT & ENGINEERING, 2023, 31 (06): : 102 - 108
  • [33] Study on the impact of partition photovoltaic electrochromic windows on building lighting environment and energy saving
    Wu, Xin
    Zhang, Wei
    Xie, Lingzhi
    Zhao, Oufan
    Li, Zihao
    Li, Jianhui
    Zhong, Jianmei
    [J]. ENERGY AND BUILDINGS, 2023, 280
  • [34] Assessment of potential energy saving using cluster analysis: A case study of lighting systems in buildings
    Petcharat, Siriwarin
    Chungpaibulpatana, Supachart
    Rakkwamsuk, Pattana
    [J]. ENERGY AND BUILDINGS, 2012, 52 : 145 - 152
  • [35] Building Information Modelling for analysis of energy efficient industrial buildings - A case study
    Gourlis, Georgios
    Kovacic, Iva
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 68 : 953 - 963
  • [36] Building Energy Index: A Case Study of Three Government Office Buildings in Malaysia
    Tahir, Mohamad Zamhari
    Nawi, Mohd Nasrun Mohd
    Rajemi, Mohamad Farizal
    [J]. ADVANCED SCIENCE LETTERS, 2015, 21 (06) : 1798 - 1801
  • [37] An economic perspective on the reliability of lighting systems in building with highly efficient energy: A case study
    Salata, F.
    Vollaro, A. de Lieto
    Ferraro, A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 84 : 623 - 632
  • [38] Impact of Changes in the Required Thermal Insulation of Building Envelope on Energy Demand, Heating Costs, Emissions, and Temperature in Buildings
    Jezierski, Walery
    Sadowska, Beata
    Pawlowski, Krzysztof
    [J]. ENERGIES, 2021, 14 (01)
  • [39] Sustainability and Energy Efficiency: BIM 6D. Study of the BIM Methodology Applied to Hospital Buildings. Value of Interior Lighting and Daylight in Energy Simulation
    Javier Montiel-Santiago, Francisco
    Jesus Hermoso-Orzaez, Manuel
    Terrados-Cepeda, Julio
    [J]. SUSTAINABILITY, 2020, 12 (14) : 1 - 29
  • [40] A Simulation and Experimental Study of the Impact of Passive and Active Facade Systems on the Energy performance of Building Perimeter Zones
    Chan, Ying-Chieh
    Tzempelikos, Athanasios
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 149 - 156