ENERGY EFFICIENT HUMAN CENTERED OFFICE LIGHTING: A CASE STUDY ON OPEN PLAN OFFICE WITH ABSENT ACCESS TO DAYLIGHT

被引:1
|
作者
Aliparast, Sevda [1 ]
Onaygil, Sermin [1 ]
机构
[1] Istanbul Tech Univ, Inst Energy Sci & Technol, Istanbul, Turkiye
来源
LIGHT & ENGINEERING | 2023年 / 31卷 / 06期
关键词
human centred lighting; dynamic height; equivalent melanopic illuminance (m-lx); circadian stimulus; vertical illuminance (vertical lx); IMPACT;
D O I
10.33383/2023-052
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
1Our daily behaviours and physiological functions are regulated by the brain's central biological clock. Consistent exposure to bright days and dim nights is crucial for aligning these rhythms. Since we spend much time indoors, electrical lighting is often relied upon to sync our circadian rhythms. A challenge in promoting circadian entrainment through electrical lighting is the lack of a standard-ized test for assessing how effectively lighting luminaires provide circadian-effective light to occu-pants. This study introduces a case study, optimum suspended height (OSH), measuring luminaire ef-ficiency in achieving a circadian stimulus criteri-on (CS: 0.3) and equivalent melanopic illuminance in lx (EML: 240) for 38 office workers, based on performance and comfort criteria. The paper out-lines OSH application to individual linear lumi-naire type, including suspended-mounted fixtures. In this field study, tests were conducted to explore how indoor lighting affects occupants' cognitive performance and visual perception. Linear sus-pended LED luminaires (LSL) were installed in an open-plan office at Istanbul Technical University (ITU), where office workers were exposed to different heights of lighting conditions. They took visual attention tests and assessed proofreading comfort, with alertness measured using the Karolinska Sleep iness Scale (KSS) test. The study aimed to under-stand the impact of visual fatigue on cognitive performance and perception with. These initial findings shed light on the relationship between office lighting changes and occupants' cognitive performance and visual perception.
引用
收藏
页码:102 / 108
页数:139
相关论文
共 50 条
  • [1] Examination of the impact of lighting layout on energy efficiency in the case of open plan office
    Sogukoglu, Mehmet
    Ozturk, Leyla Dokuzer
    MEGARON, 2024, 19 (01): : 27 - 37
  • [2] Assessing Anidolic Daylighting System for efficient daylight in open plan office in the tropics
    Roshan, Mohsen
    Barau, Aliyu Salisu
    JOURNAL OF BUILDING ENGINEERING, 2016, 8 : 58 - 69
  • [3] OPEN-PLAN OFFICE LIGHTING.
    Orfield, Steven J.
    Lighting Design and Application: LD and A, 1987, 17 (07) : 7 - 19
  • [4] EFFECT OF PARTITIONS ON DAYLIGHT PENETRATION IN OPEN PLAN OFFICE SPACES
    Saraiji, R.
    Safadi, M. Y.
    PROCEEDINGS OF CIE 2012 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2012, : 286 - 296
  • [5] Saving Energy with Highly-Controlled Lighting in an Open-Plan Office
    Rubinstein, Francis
    Enscoe, Abby
    LEUKOS, 2010, 7 (01) : 21 - 36
  • [6] A Field Study of Individual, Energy-Efficient, and Human-Centered Indoor Electric Lighting: Its Impact on Comfort and Visual Performance in an Open-Plan Office Part 1
    Aliparast, Sevda
    Onaygil, Sermin
    BUILDINGS, 2024, 14 (04)
  • [7] Energy efficient thermal comfort in open-plan office buildings
    Nagarathinam, Srinarayana
    Doddi, Harish
    Vasan, Arunchandar
    Sarangan, Venkatesh
    Ramakrishna, Venkata P.
    Sivasubramaniam, Anand
    ENERGY AND BUILDINGS, 2017, 139 : 476 - 486
  • [8] Effects of Volume and Lighting Equipment Features on Lighting in An Open Plan Office: An Analysis
    Celik, Kasim
    Kucukkilic Ozcan, Esra
    Unver, Rengin
    MEGARON, 2015, 10 (01): : 80 - 91
  • [9] Office Lighting Simulation: Energy implications with scheduled occupancy and daylight harvesting
    Kurian, Ciji Pearl
    George, V. I.
    Pallavi, K.
    Varghese, Manu
    2018 INTERNATIONAL CONFERENCE ON CONTROL, POWER, COMMUNICATION AND COMPUTING TECHNOLOGIES (ICCPCCT), 2018, : 129 - 135
  • [10] Lighting and cooling energy consumption in an open-plan office using solar film coating
    Li, Danny H. W.
    Lam, Tony N. T.
    Wong, S. L.
    Tsang, Ernest K. W.
    ENERGY, 2008, 33 (08) : 1288 - 1297