Comparison of Denoising Methods in Diffusion Tensor Imaging

被引:0
|
作者
Johnson, Solwin [1 ]
Balakrishnan, Arun A. [1 ]
机构
[1] Rajagiri Sch Engn & Technol, Dept Appl Elect & Instrumentat, Cochin, Kerala, India
关键词
Diffusion Tensor Imaging (DTI); Diffusion weighted (DW) image; Non linear adaptive gaussian method; Peak signal-to-noise ratio (PSNR); Mean structural similarity index measure (MSSIM);
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In this paper, a non linear adaptive gaussian denoising method for diffusion tensor imaging (DTI) is proposed. DTI image are of poor SNR and low resolution images. In order to improve DTI, the proposed method is applied to the diffusion weighted images (DWI) from which DTI is computed. The anisotropic flow principle is used in non linear adaptive gaussian denoising method and smoothing will vary according to the anisotropic flow. The proposed method is compared with the scalar Partial Differential Equation (PDE) denoising method. The non linear adaptive gaussian denoising method shows better performance compared to scalar PDE. To evaluate the efficiency of both denoising methods, image quality metrics like peak signal-to-noise ratio (PSNR) and mean structural similarity index measure (MSSIM) are used. The experimental results indicate the good performance of proposed method and it has a better denoising effect in DTI compared to scalar PDE.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Comparison of region-of-interest delineation methods for diffusion tensor imaging in patients with cervical spondylotic radiculopathy
    Penghuan Wu
    Chengyan Huang
    Benchao Shi
    Anmin Jin
    [J]. BMC Musculoskeletal Disorders, 23
  • [22] COMPARISON OF LEUKEMIC AND CONTROLS SUBJECTS USING DIFFUSION TENSOR IMAGING
    Rollins, Nancy K.
    Winick, Naomi
    Gimi, Barjor
    Chia, Jonathon
    Wang, Jerry
    [J]. PEDIATRIC BLOOD & CANCER, 2009, 52 (06) : 715 - 715
  • [23] Comparison of quality control software tools for diffusion tensor imaging
    Liu, Bilan
    Zhu, Tong
    Zhong, Jianhui
    [J]. MAGNETIC RESONANCE IMAGING, 2015, 33 (03) : 276 - 285
  • [24] Comparison of regularization methods for human cardiac diffusion tensor MRI
    Frindel, Carole
    Robini, Marc
    Croisille, Pierre
    Zhu, Yue-Min
    [J]. MEDICAL IMAGE ANALYSIS, 2009, 13 (03) : 405 - 418
  • [25] Pediatric diffusion and diffusion tensor imaging
    Glasier, Charles M.
    [J]. PEDIATRIC RADIOLOGY, 2007, 37 (08) : 733 - 733
  • [26] Pediatric diffusion and diffusion tensor imaging
    Charles M. Glasier
    [J]. Pediatric Radiology, 2007, 37 : 733 - 733
  • [27] Comparison of Diffusion Kurtosis Imaging and Diffusion Tensor Imaging Tractography Measures in Relation to Anhedonia in Young Adults
    Greenberg, Tsafrir
    Versace, Amelia
    Chase, Henry
    Stiffler, Richelle
    Lockovich, Jeanette
    Aslam, Haris
    Bebko, Genna
    Phillips, Mary
    [J]. NEUROPSYCHOPHARMACOLOGY, 2015, 40 : S174 - S175
  • [28] About Advances in Tensor Data Denoising Methods
    Marot, Julien
    Fossati, Caroline
    Bourennane, Salah
    [J]. EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2008, 2008 (1)
  • [29] About Advances in Tensor Data Denoising Methods
    Julien Marot
    Caroline Fossati
    Salah Bourennane
    [J]. EURASIP Journal on Advances in Signal Processing, 2008
  • [30] Diffusion-Weighted Imaging and Diffusion Tensor Imaging
    Raya J.G.
    [J]. Current Radiology Reports, 2 (3)