Prospective Comparison of 70-kVp Single -Energy CT versus Dual -Energy CT: Which is More Suitable for CT Angiography with Low Contrast Media

被引:8
|
作者
Yoshida, Morikatsu [1 ]
Nakaura, Takeshi [2 ]
Sentaro, Takada [1 ]
Tanoue, Shota [2 ]
Inada, Hatsuki [1 ]
Utsunomiya, Daisuke [3 ]
Sakaino, Naritsugu [4 ]
Harada, Kazunori [5 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Amakusa Med Ctr, Dept Radiol, 854-1 Jikiba, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Dept Diagnost Radiol, Fac Life Sci, Kumamoto, Japan
[3] Yokohama City Univ, Dept Radiol, Sch Med, Yokohama, Kanagawa, Japan
[4] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto, Japan
[5] Amakusa Med Ctr, Dept Surg, Kumamoto, Japan
关键词
ABDOMINAL DYNAMIC CT; LOW TUBE VOLTAGE; RENAL-FAILURE; AORTOGRAPHY; REDUCTION; SETTINGS; IMPACT; NOISE;
D O I
10.1016/j.acra.2019.07.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare the objective and subjective image qualities between single-energy computed tomography (CT) at 70 kVp and virtual monoenergetic imaging (VMI) of dual-source dual-energy CT for CT angiography with 180 mgI/kg. Materials and Methods: Total 63 patients scanned with 180 mgI/kg were randomly divided into two groups: Group A (32 patients) underwent CT angiography at 70-kVp, and Group B (31 patients) underwent dual-energy CT. VMI sets were generated at 10-keV increments between 40 and 100 keV. We calculated aortic attenuation, contrast-to-noise-ratio (CNR), signal-to-noise-ratio, figure of merit of CNR, and effective dose for each protocol. Three radiologists scored overall image quality and various arteries’ visibility using a four-point scale. Quantitative and qualitative comparisons between 70 kVp and VMI with the highest CNR were performed with the two-tailed t test or Kruskal–Wallis test. Results: The 40-keV images offered the highest CNR among VMIs. Aortic attenuation at 70 kVp was significantly lower than that at 40 keV (p < 0.001). However, the signal-to-noise-ratio, CNR, and figure of merit of CNR were significantly higher at 70 kVp than those at 40-keV (p < 0.001, p < 0.05, and p < 0.05, respectively). The effective dose of each group was almost equal. The qualitative visibility scores for various arteries, except the ascending and upper-abdominal aorta, were also better at 70 kVp than those at 40 keV. Conclusion: Aortic attenuation at 70 kVp with 180 mg I/kg was lower than that of VMI at 40 keV, and the objective and subjective image qualities were higher at 70 kVp than those at 40 keV. © 2019 The Association of University Radiologists
引用
收藏
页码:E116 / E122
页数:7
相关论文
共 50 条
  • [1] Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma
    Yoo, Jeongin
    Lee, Jeong Min
    Yoon, Jeong Hee
    Joo, Ijin
    Lee, Eun Sun
    Jeon, Sun Kyung
    Jang, Siwon
    ABDOMINAL RADIOLOGY, 2021, 46 (07) : 3217 - 3226
  • [2] Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma
    Jeongin Yoo
    Jeong Min Lee
    Jeong Hee Yoon
    Ijin Joo
    Eun Sun Lee
    Sun Kyung Jeon
    Siwon Jang
    Abdominal Radiology, 2021, 46 : 3217 - 3226
  • [3] Identification of contrast media in PET/CT using dual energy CT
    Freedman, Nanette M. T.
    Moreno, Roberto Maass
    Le Meunier, Ludovic
    Bacharach, Stephen L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) : 523 - 527
  • [4] Dual-Energy and Low-kVp CT in the Abdomen
    Yeh, Benjamin M.
    Shepherd, John A.
    Wang, Zhen J.
    Teh, Hui Seong
    Hartman, Robert P.
    Prevrhal, Sven
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (01) : 47 - 54
  • [5] Dual-energy CT angiography of abdomen with routine concentration contrast agent in comparison with conventional single-energy CT with high concentration contrast agent
    He, Jingzhen
    Wang, Qing
    Ma, Xiangxing
    Sun, Zhiyuan
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (02) : 221 - 227
  • [6] Dosimetric comparison: Virtual Unenhanced Dual Energy CT versus contrast CT for treatment planning
    Afifah, M.
    den Boer, D.
    Bulthuis, L.
    Rosario, T.
    Verbeek-Spijkerman, J.
    Bel, A.
    van Kesteren, Z.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S552 - S554
  • [7] Low-Contrast Agent Dose Dual-Energy CT Monochromatic Imaging in Pulmonary Angiography Versus Routine CT
    Dong, Jian
    Wang, Xiaoying
    Jiang, Xuexiang
    Gao, Li
    Li, Feiyu
    Qiu, Jianxing
    Xu, Yufeng
    Wang, He
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 618 - 625
  • [8] Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography
    Tao, Shu Min
    Li, Xie
    Schoepf, U. Joseph
    Nance, John W., Jr.
    Jacobs, Brian E.
    Zhou, Chang Sheng
    Gu, Hai Feng
    Lu, Meng Jie
    Lu, Guang Ming
    Zhang, Long Jiang
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 : 92 - 96
  • [9] Assessment of Calcified Carotid Plaque Volume: Comparison of Contrast-Enhanced Dual-Energy CT Angiography and Native Single-Energy CT
    Watanabe, Yoshiyuki
    Nakazawa, Tetsuro
    Higashi, Masahiro
    Itoh, Toshihide
    Naito, Hiroaki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W796 - W799
  • [10] Dual energy CT angiography for lower extremity trauma: comparison with conventional CT
    Rajat Joshi
    Christina LeBedis
    Kevin Dao
    Mohammed Qureshi
    Avneesh Gupta
    Emergency Radiology, 2022, 29 : 471 - 477