Long-term comparison of Charnley and Stanmore design total hip replacements

被引:48
|
作者
Britton, AR [1 ]
Murray, DW [1 ]
Bulstrode, CJ [1 ]
McPherson, K [1 ]
Denham, RA [1 ]
机构
[1] NUFFIELD ORTHOPAED CTR,DEPT ORTHOPAED SURG,OXFORD OX3 7LD,ENGLAND
来源
关键词
D O I
10.1302/0301-620X.78B5.0780802
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the records of the long-term outcome of 208 Charnley and 982 Stanmore total hip replacements (THR) performed by or under the supervision of one surgeon from 1973 to 1987, The Stanmore implant had a better survival rate before revision at 14 years (86% to 79%, p=0.004), but the difference only became apparent at ten years, The later Stanmore implants did better than the early ones (97% to 92% at ten years, p=0,005), the improvement coinciding with the introduction of a new cementing technique using a gun, Most of the Charnley implants were done before most of the Stanmore implants so that the difference between the results may in part be explained by improved methods, but this is not the complete explanation since a difference persisted for implants carried out during the same period of time, We conclude that improved techniques have reduced failure rates substantially. This improvement was much greater than that observed between these two designs of implant, Proof of the difference would require a very large randomised controlled trial over a ten-year period.
引用
收藏
页码:802 / 808
页数:7
相关论文
共 50 条
  • [21] A predictive analysis of long-term friction and wear characteristics of metal-on-metal total hip replacements
    Dowson, D.
    Wang, F. C.
    Wang, W. Z.
    Jin, Z. M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2007, 221 (J3) : 460 - 460
  • [22] Long-term results of charnley low-friction arthroplasty in tuberculosis of the hip
    Kim, YY
    Ahn, JY
    Sung, YB
    Ko, CU
    Shim, JC
    Park, HS
    Bai, GH
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 106 - 110
  • [23] Methodology for long-term wear testing of total knee replacements
    Walker, PS
    Blunn, GW
    Perry, JP
    Bell, CJ
    Sathasivam, S
    Andriacchi, TP
    Paul, JP
    Haider, H
    Campbell, PA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (372) : 290 - 301
  • [24] Long-term outcome of cemented total hip arthroplasty with the Charnley-type femoral stem made of titanium alloy
    Okutani, Yuki
    Goto, Koji
    Kuroda, Yutaka
    Kawai, Toshiyuki
    Okuzu, Yaichiro
    Kawata, Tomotoshi
    Shimizu, Yu
    Matsuda, Shuichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (06) : 1047 - 1052
  • [25] LONG-TERM RESULTS OF CHARNLEY THR
    WEJKNER, B
    STENPORT, J
    HINDMARSH, J
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (01): : 97 - 98
  • [26] LONG-TERM RESULTS OF TOTAL PROSTHESES OF HIP
    MAZAS, F
    GAZETTE MEDICALE DE FRANCE, 1977, 84 (06): : 553 - &
  • [27] PRESS-FIT DESIGN IN TOTAL HIP-REPLACEMENT - A COMPARISON BETWEEN THE LUBINUS AND STANMORE PROSTHESES
    BURGAARD, P
    OLSEN, PA
    JENSEN, NM
    ANDERSEN, PB
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 326 - 326
  • [28] LONG-TERM FOLLOW-UP OF CHARNLEY LOW-FRICTION ARTHROPLASTY OF THE HIP
    DALL, DM
    LEARMONTH, ID
    DALL, G
    GROBBELAAR, CJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (03): : 503 - 503
  • [29] Long term data concerning the use of alumina on alumina bearings in total hip replacements
    Sedel, L
    Hamadouche, M
    Bizot, P
    Nizard, R
    BIOCERAMICS 15, 2003, 240-2 : 769 - 772
  • [30] Long-term survival analysis of total hip replacement
    Birtwistle, SJ
    Wilson, K
    Porter, ML
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1996, 78 (03) : 180 - 183