Articular cartilage defects detected with 3D water-excitation true FISP: Prospective comparison with sequences commonly used for knee imaging

被引:76
|
作者
Duc, Sylvain R.
Pfirrmann, Christian W. A.
Schmid, Marius R.
Zanetti, Marco
Koch, Peter P.
Kalberer, Fabian
Hodler, Juerg
机构
[1] Univ Hosp, Dept Radiol, CH-8008 Zurich, Switzerland
[2] Univ Hosp, Dept Orthoped Surg, CH-8008 Zurich, Switzerland
关键词
D O I
10.1148/radiol.2451060990
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively compare the accuracy of three-dimensional (3D) water-excitation (WE) true fast imaging with steady-state precession (FISP) in the diagnosis of articular cartilage defects with that of sequences commonly used to image the knee, with arthroscopy or surgery as the reference standard. Materials and Methods: This study protocol was institutional review board approved. Written informed consent was obtained from all patients. Thirty knees in 29 patients (mean age, 56 years; range, 18-86 years) were prospectively evaluated by using sagittal 3D WE true FISP with two section thicknesses (1.7 mm [true FISPthin] and 3.0 mm [true FISPthick]), two-dimensional (2D) intermediate-weighted spin-echo with fat saturation, 2D fast short inversion time inversion-recovery, 3D WE double-echo steady-state, and 3D fat-saturated fast low-angle shot sequences. Cartilage defects were graded on magnetic resonance images and during surgery with a modified Noyes scoring system. Contrast-to-noise ratio (CNR) and CNR efficiency were calculated. Sensitivity, specificity, and accuracy were assessed. Inter-observer agreement was determined with kappa statistics, and quantitative results were evaluated with the Wilcoxon signed rank test. Results: The performance of 3D WE true FISPthick (sensitivity, specificity, and accuracy, respectively, were 52%, 93%, and 71% for reader 1 and 65%, 88%, and 76% for reader 2) and 3D WE true FISPthin (sensitivity, specificity, and accuracy, respectively, were 58%, 94%, and 75% for reader 1 and 63%, 80%, and 71% for reader 2) sequences was no different than that of other sequences in the detection of circumscribed defects. Three-dimensional WE true FISP sequences had a significantly (P < .0033) higher CNR and CNR efficiency between cartilage and fluid than the corresponding sequences with the same section thickness. Conclusion: Three-dimensional WE true FISP enables high contrast between joint fluid and articular cartilage and a diagnostic performance that is comparable with that of standard sequences.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 42 条
  • [41] Simultaneous fat-free isotropic 3D anatomical imaging and T2 mapping of knee cartilage with lipid-insensitive binomial off-resonant RF excitation (LIBRE) pulses
    Colotti, Roberto
    Omoumi, Patrick
    van Heeswijk, Ruud B.
    Bastiaansen, Jessica A. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (05) : 1275 - 1284
  • [42] IDEAL 3D spoiled gradient echo of the articular cartilage of the knee on 3.0T MRI: a comparison with conventional 3.0T fast spin-echo T2 fat saturation image
    Han, Chul Hee
    Park, Hee Jin
    Lee, So Yeon
    Chung, Eun Chul
    Choi, Seon Hyeong
    Yun, Ji Sup
    Rho, Myung Ho
    ACTA RADIOLOGICA, 2015, 56 (12) : 1479 - 1486