Articular cartilage defects detected with 3D water-excitation true FISP: Prospective comparison with sequences commonly used for knee imaging

被引:76
|
作者
Duc, Sylvain R.
Pfirrmann, Christian W. A.
Schmid, Marius R.
Zanetti, Marco
Koch, Peter P.
Kalberer, Fabian
Hodler, Juerg
机构
[1] Univ Hosp, Dept Radiol, CH-8008 Zurich, Switzerland
[2] Univ Hosp, Dept Orthoped Surg, CH-8008 Zurich, Switzerland
关键词
D O I
10.1148/radiol.2451060990
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively compare the accuracy of three-dimensional (3D) water-excitation (WE) true fast imaging with steady-state precession (FISP) in the diagnosis of articular cartilage defects with that of sequences commonly used to image the knee, with arthroscopy or surgery as the reference standard. Materials and Methods: This study protocol was institutional review board approved. Written informed consent was obtained from all patients. Thirty knees in 29 patients (mean age, 56 years; range, 18-86 years) were prospectively evaluated by using sagittal 3D WE true FISP with two section thicknesses (1.7 mm [true FISPthin] and 3.0 mm [true FISPthick]), two-dimensional (2D) intermediate-weighted spin-echo with fat saturation, 2D fast short inversion time inversion-recovery, 3D WE double-echo steady-state, and 3D fat-saturated fast low-angle shot sequences. Cartilage defects were graded on magnetic resonance images and during surgery with a modified Noyes scoring system. Contrast-to-noise ratio (CNR) and CNR efficiency were calculated. Sensitivity, specificity, and accuracy were assessed. Inter-observer agreement was determined with kappa statistics, and quantitative results were evaluated with the Wilcoxon signed rank test. Results: The performance of 3D WE true FISPthick (sensitivity, specificity, and accuracy, respectively, were 52%, 93%, and 71% for reader 1 and 65%, 88%, and 76% for reader 2) and 3D WE true FISPthin (sensitivity, specificity, and accuracy, respectively, were 58%, 94%, and 75% for reader 1 and 63%, 80%, and 71% for reader 2) sequences was no different than that of other sequences in the detection of circumscribed defects. Three-dimensional WE true FISP sequences had a significantly (P < .0033) higher CNR and CNR efficiency between cartilage and fluid than the corresponding sequences with the same section thickness. Conclusion: Three-dimensional WE true FISP enables high contrast between joint fluid and articular cartilage and a diagnostic performance that is comparable with that of standard sequences.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 42 条
  • [21] Accurate 3D reconstruction of subject-specific knee finite element model to simulate the articular cartilage defects
    Dong Y.-F.
    Hu G.-H.
    Zhang L.-L.
    Hu Y.
    Dong Y.-H.
    Xu Q.-R.
    Journal of Shanghai Jiaotong University (Science), 2011, 16 (5) : 620 - 627
  • [22] Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3 T system scientific research
    Milewski, Matthew D.
    Smitaman, Edward
    Moukaddam, Hicham
    Katz, Lee D.
    Essig, David A.
    Medvecky, Michael J.
    Haims, Andrew H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1637 - 1643
  • [23] MR enteroclysis protocol optimization: comparison between 3D FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences
    Gourtsoyiannis, N
    Papanikolaou, N
    Grammatikakis, J
    Maris, T
    Prassopoulos, P
    EUROPEAN RADIOLOGY, 2001, 11 (06) : 908 - 913
  • [24] MR enteroclysis protocol optimization: comparison between 3D FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences
    Nicholas Gourtsoyiannis
    Nickolas Papanikolaou
    John Grammatikakis
    Thomas Maris
    Panos Prassopoulos
    European Radiology, 2001, 11 : 908 - 913
  • [25] Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions
    Li, X.
    Yu, C.
    Wu, H.
    Daniel, K.
    Hu, D.
    Xia, L.
    Pan, C.
    Xu, A.
    Hu, J.
    Wang, L.
    Peng, W.
    Li, F.
    CLINICAL RADIOLOGY, 2009, 64 (10) : 1000 - 1008
  • [26] Assessment of the uterine artery before uterine arterial embolization: Comparison of unenhanced 3D water-excitation sensitivity-encoding time-of-flight (WEST) and gadolinium-enhanced 3D sensitivity-encoding water-excitation multishot echo-planar (SWEEP) MR angiography
    Mori, Kensaku
    Shiigai, Masanari
    Ueda, Takuya
    Kita, Naoki
    Tanaka, Nami
    Minami, Manabu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 557 - 562
  • [27] Comparison of different material models of articular cartilage in 3D computational modeling of the knee: Data from the Osteoarthritis Initiative (OAI)
    Klets, Olesya
    Mononen, Mika E.
    Tanska, Petri
    Nieminen, Miika T.
    Korhonen, Rami K.
    Saarakkala, Simo
    JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 3891 - 3900
  • [28] MR Arthrography of the hip: Diagnostic performance of a dedicated water-excitation 3D double-echo steady-state sequence to detect cartilage lesions
    Knuesel, PR
    Pfirrmann, CWA
    Noetzli, HP
    Dora, C
    Zanetti, M
    Hodler, J
    Kuehn, B
    Schmid, MR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (06) : 1729 - 1735
  • [29] High-resolution cartilage imaging of the knee at 3 T: Basic evaluation of modern isotropic 3D MR-sequences
    Friedrich, Klaus M.
    Reiter, Gert
    Kaiser, Bernd
    Mayerhoefer, Marius
    Deimling, Michael
    Jellus, Vladimir
    Horger, Wilhelm
    Trattnig, Siegfried
    Schweitzer, Mark
    Salomonowitz, Erich
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (03) : 398 - 405
  • [30] Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging
    B. J. Murphy
    Skeletal Radiology, 2001, 30 : 305 - 311