Articular cartilage defects detected with 3D water-excitation true FISP: Prospective comparison with sequences commonly used for knee imaging

被引:76
|
作者
Duc, Sylvain R.
Pfirrmann, Christian W. A.
Schmid, Marius R.
Zanetti, Marco
Koch, Peter P.
Kalberer, Fabian
Hodler, Juerg
机构
[1] Univ Hosp, Dept Radiol, CH-8008 Zurich, Switzerland
[2] Univ Hosp, Dept Orthoped Surg, CH-8008 Zurich, Switzerland
关键词
D O I
10.1148/radiol.2451060990
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively compare the accuracy of three-dimensional (3D) water-excitation (WE) true fast imaging with steady-state precession (FISP) in the diagnosis of articular cartilage defects with that of sequences commonly used to image the knee, with arthroscopy or surgery as the reference standard. Materials and Methods: This study protocol was institutional review board approved. Written informed consent was obtained from all patients. Thirty knees in 29 patients (mean age, 56 years; range, 18-86 years) were prospectively evaluated by using sagittal 3D WE true FISP with two section thicknesses (1.7 mm [true FISPthin] and 3.0 mm [true FISPthick]), two-dimensional (2D) intermediate-weighted spin-echo with fat saturation, 2D fast short inversion time inversion-recovery, 3D WE double-echo steady-state, and 3D fat-saturated fast low-angle shot sequences. Cartilage defects were graded on magnetic resonance images and during surgery with a modified Noyes scoring system. Contrast-to-noise ratio (CNR) and CNR efficiency were calculated. Sensitivity, specificity, and accuracy were assessed. Inter-observer agreement was determined with kappa statistics, and quantitative results were evaluated with the Wilcoxon signed rank test. Results: The performance of 3D WE true FISPthick (sensitivity, specificity, and accuracy, respectively, were 52%, 93%, and 71% for reader 1 and 65%, 88%, and 76% for reader 2) and 3D WE true FISPthin (sensitivity, specificity, and accuracy, respectively, were 58%, 94%, and 75% for reader 1 and 63%, 80%, and 71% for reader 2) sequences was no different than that of other sequences in the detection of circumscribed defects. Three-dimensional WE true FISP sequences had a significantly (P < .0033) higher CNR and CNR efficiency between cartilage and fluid than the corresponding sequences with the same section thickness. Conclusion: Three-dimensional WE true FISP enables high contrast between joint fluid and articular cartilage and a diagnostic performance that is comparable with that of standard sequences.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 42 条
  • [1] Diagnosis of articular cartilage abnormalities of the knee: Prospective clinical evaluation of a 3D water-excitation true FISP sequence
    Duc, Sylvain R.
    Koch, Peter
    Schmid, Marius R.
    Horger, Wilhelm
    Hodler, Juerg
    Pfirrmann, Christian W. A.
    RADIOLOGY, 2007, 243 (02) : 475 - 482
  • [2] Articular cartilage and labral lesions of the glenohumeral joint: diagnostic performance of 3D water-excitation true FISP MR arthrography
    Tobias Johannes Dietrich
    Marco Zanetti
    Nadja Saupe
    Christian W. A. Pfirrmann
    Sandro F. Fucentese
    Juerg Hodler
    Skeletal Radiology, 2010, 39 : 473 - 480
  • [3] Articular cartilage and labral lesions of the glenohumeral joint: diagnostic performance of 3D water-excitation true FISP MR arthrography
    Dietrich, Tobias Johannes
    Zanetti, Marco
    Saupe, Nadja
    Pfirrmann, Christian W. A.
    Fucentese, Sandro F.
    Hodler, Juerg
    SKELETAL RADIOLOGY, 2010, 39 (05) : 473 - 480
  • [4] The value of water-excitation 3D FLASH and fat-saturated PDw TSE MR imaging for detecting and grading articular cartilage lesions of the knee
    Mohr, A
    SKELETAL RADIOLOGY, 2003, 32 (07) : 396 - 402
  • [5] The value of water-excitation 3D FLASH and fat-saturated PDw TSE MR imaging for detecting and grading articular cartilage lesions of the knee
    Andreas Mohr
    Skeletal Radiology, 2003, 32 : 396 - 402
  • [6] Morphological MR imaging of the articular cartilage of the knee at 3 T—comparison of standard and novel 3D sequences
    Van Dyck P.
    Vanhevel F.
    Vanhoenacker F.M.
    Wouters K.
    Grodzki D.M.
    Gielen J.L.
    Parizel P.M.
    Insights into Imaging, 2015, 6 (3) : 285 - 293
  • [7] Comparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defects
    Lavdas, Eleftherios
    Topalzikis, Theofilos
    Mavroidis, Panayiotis
    Kyriakis, Ioannis
    Roka, Violeta
    Kostopoulos, Spiros
    Glotsos, Dimitrios
    Zilidis, Christos
    Stathakis, Sotiris
    Tsagkalis, Antonios
    Papanikolaou, Nikos
    Batsikas, Georgios
    Arvanitis, Dimitrios L.
    Vassiou, Katerina
    MAGNETIC RESONANCE IMAGING, 2013, 31 (08) : 1255 - 1262
  • [8] COMPARISON OF 3D FLASH WITH WATER EXCITATION AND 3D FLASH WITH FAT-SUPPRESSION FOR EVALUATION OF ARTICULAR-CARTILAGE ABNORMALITIES
    CHENG, AE
    ATKINSON, DJ
    BRADLEY, WG
    HASHEMI, RH
    HENRIE, JN
    RADIOLOGY, 1995, 197 : 225 - 225
  • [9] Detection of articular cartilage defects with sagittal fat-suppressed 3D FLASH imaging
    Delfaut, EM
    Beltran, J
    Rosenberg, ZS
    Bencardino, J
    Rokito, A
    RADIOLOGY, 1997, 205 : 950 - 950
  • [10] Comparison of 3D versus 2D Fast Spin-Echo Imaging for Evaluation of Articular Cartilage in the Knee on a 3 Tesla System
    Haims, A.
    Milewski, M.
    Essig, D.
    Medvecky, M.
    Katz, L.
    Moukaddam, H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)