Harvesting 48V at the National Superconducting Cyclotron Laboratory

被引:8
|
作者
Loveless, C. Shaun [1 ,2 ]
Marois, Boone E. [3 ]
Ferran, Samuel J. [1 ]
Wilkinson, John T. [4 ]
Sutherlin, Logan [5 ]
Severin, Gregory [6 ,9 ]
Shusterman, Jennifer A. [7 ]
Scielzo, Nicholas D. [8 ]
Stoyer, Mark A. [8 ]
Morrissey, David J. [9 ]
Robertson, J. David [5 ,6 ]
Peaslee, Graham F. [4 ]
Lapi, Suzanne E. [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, 1720 2nd Ave South,WTI 310F, Birmingham, AL 35233 USA
[2] Washington Univ, Dept Chem, St Louis, MO 63134 USA
[3] Hope Coll, Dept Chem, Holland, MI 49423 USA
[4] Univ Notre Dame, Dept Phys, Notre Dame, IN 46556 USA
[5] Univ Missouri, Dept Chem, Columbia, MO 65211 USA
[6] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
[7] CUNY Hunter Coll, Dept Chem, New York, NY 10065 USA
[8] Lawrence Livermore Natl Lab, Nucl & Chem Sci Div, Livermore, CA 94550 USA
[9] Michigan State Univ, Natl Superconducting Cyclotron Lab, E Lansing, MI 48824 USA
关键词
V-48; Isotope harvesting; Heavy-ion fragmentation; National superconducting cyclotron laboratory; SEPARATION; CHROMIUM; VANADIUM;
D O I
10.1016/j.apradiso.2019.109023
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
As part of an effort to develop aqueous isotope harvesting techniques at radioactive beam facilities, V-48 and a cocktail of primary- and secondary-beam ions created by the fragmentation reaction of a 160 MeV/nucleon Ni-58 beam were stopped in an aqueous target cell. After collection, V-48 was separated from the mixture of beam ions using cation-exchange chromatography. The extraction efficiency from the aqueous solution was (47.0 +/- 2.5)%, and the isolated V-48 had a radiochemical purity of 95.8%. This proof-of-concept work shows that aqueous isotope harvesting could provide significant quantities of rare isotopes which are currently unavailable at conventional facilities.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Investigation of topology candidates for 48V VRM
    Ye, M
    Xu, P
    Yang, B
    Lee, FC
    APEC 2002: SEVENTEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 23, 2002, : 699 - 705
  • [32] Proof-of-concept studies of novel protocols for producing highly pure 48V from a 48Cr/48V generator
    Essenmacher, Scott D.
    Kleinfeldt, Chloe R.
    Domnanich, Katharina A.
    Bodnar, Vladyslav S.
    Vyas, Chirag K.
    Severin, Gregory W.
    APPLIED RADIATION AND ISOTOPES, 2023, 199
  • [33] Convert 48V to an isolated regulated 5V
    Sherman, L
    Schindler, M
    ELECTRONIC ENGINEERING, 1996, 68 (830): : 34 - 34
  • [34] Production, Collection, and Purification of 47Ca for the Generation of 47Sc through Isotope Harvesting at the National Superconducting Cyclotron Laboratory
    Abel, E. Paige
    Domnanich, Katharina
    Clause, Hannah K.
    Kalman, Colton
    Walker, Wes
    Shusterman, Jennifer A.
    Greene, John
    Gott, Matthew
    Severin, Gregory W.
    ACS OMEGA, 2020, 5 (43): : 27864 - 27872
  • [35] NUCLEAR ORIENTATION OF 48V NUCLEI IN IRON AND COBALT
    CAMERON, JA
    COMPTON, JP
    LINES, RAG
    WILSON, GVH
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1966, 87 (558P): : 927 - &
  • [36] 48V超级电容模组的研究
    陈朝晖
    张伟先
    黄钰强
    技术与市场, 2015, 22 (05) : 68 - 69
  • [37] 如何选择48V电源母线架构
    Gorden Mack
    今日电子, 2005, (12) : 43 - 44
  • [38] Precision circuit closely monitors - 48V bus
    Smith, P
    Staley, J
    EDN, 2002, 47 (23) : 100 - +
  • [39] 48V系统技术发展概述
    张昶
    付磊
    汽车文摘, 2019, (01) : 10 - 15