Development of a more accurate Geant4 quantum molecular dynamics model for hadron therapy

被引:5
|
作者
Sato, Yoshi-hide [1 ]
Sakata, Dousatsu [2 ,3 ]
Bolst, David [4 ]
Simpson, Edward C. [5 ]
Guatelli, Susanna [4 ]
Haga, Akihiro [1 ]
机构
[1] Tokushima Univ, Dept Biol Sci, Tokushima 7708503, Japan
[2] Inst Quantum Med Sci, Dept Accelerator & Med Phys, QST, Chiba 2638555, Japan
[3] Osaka Univ, Grad Sch Med, Div Hlth Sci, Osaka 5650871, Japan
[4] Univ Wollongong, Ctr Med & Radiat Phys, Wollongong 2522, Australia
[5] Australian Natl Univ, Res Sch Phys, Dept Nucl Phys & Accelerator Applicat, CanberraACT 2601, Canberra, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 22期
关键词
hadron therapy; fragmentation; quantum molecular dynamics; multi-objective optimization; CARBON-ION RADIOTHERAPY; GROUND-STATE PROPERTIES; NUCLEAR FRAGMENTATION; VALIDATION; BEAMS; PARAMETRIZATION; PROTON;
D O I
10.1088/1361-6560/ac9a9a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Although in heavy-ion therapy, the quantum molecular dynamics (QMD) model is one of the most fundamental physics models providing an accurate daughter-ion production yield in the final state, there are still non-negligible differences with the experimental results. The aim of this study is to improve fragment production in water phantoms by developing a more accurate QMD model in Geant4. Approach. A QMD model was developed by implementing modern Skyrme interaction parameter sets, as well as by incorporating with an ad hoc alpha-cluster model in the initial nuclear state. Two adjusting parameters were selected that can significantly affect the fragment productions in the QMD model: the radius to discriminate a cluster to which nucleons belong after the nucleus-nucleus reaction, denoted by R, and the squared standard deviation of the Gaussian packet, denoted by L. Squared Mahalanobis's distance of fragment yields and angular distributions with 1, 2, and the higher atomic number for the produced fragments were employed as objective functions, and multi-objective optimization (MOO), which make it possible to compare quantitatively the simulated production yields with the reference experimental data, was performed. Main results. The MOO analysis showed that the QMD model with modern Skyrme parameters coupled with the proposed alpha-cluster model, denoted as SkM* alpha, can drastically improve light fragments yields in water. In addition, the proposed model reproduced the kinetic energy distribution of the fragments accurately. The optimized L in SkM* alpha was confirmed to be realistic by the charge radii analysis in the ground state formation. Significance. The proposed framework using MOO was demonstrated to be very useful in judging the superiority of the proposed nuclear model. The optimized QMD model is expected to improve the accuracy of heavy-ion therapy dosimetry.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Geant4 pre-compound model upgrade
    Chalyi, N. A.
    Ivanchenko, V. N.
    RUSSIAN PHYSICS JOURNAL, 2024, 67 (11) : 1962 - 1968
  • [22] New Geant4 Developments for Doppler Broadening Simulation in Compton Scattering - Development of Charge Transfer Simulation Models in Geant4
    Longo, Francesco
    Pandola, Luciano
    Pia, Maria Grazia
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2140 - +
  • [23] GEANT4 neutrino-electron interaction model
    Grichine, V. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 942
  • [24] Description of Hadron-induced Showers in Calorimeters using the GEANT4 Simulation Toolkit
    Dotti, Andrea
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2128 - 2134
  • [25] Carbon-Ion Therapy in the Geant4 Binary Light Ion Cascade Model
    Sirisha, S. N. L.
    Bhatnagar, Sonali
    PROCEEDINGS OF THE INDIAN NATIONAL SCIENCE ACADEMY, 2019, 85 (04): : 819 - 827
  • [26] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 896 - 901
  • [27] Development and verification of a Geant4 model of the electron beam mode in a clinical linear accelerator
    Miloichikova, I.
    Bulavskaya, A.
    Bushmina, E.
    Dusaev, R.
    Gargioni, E.
    Gavrikov, B.
    Grigorieva, A.
    Stuchebrov, S.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (07):
  • [28] Validation of Geant4 for silicon microdosimetry in heavy ion therapy
    Bolst, D.
    Guatelli, S.
    Tran, L. T.
    Chartier, L.
    Davis, J.
    Biasi, G.
    Prokopovich, D. A.
    Pogossov, A.
    Reinhard, M., I
    Petasecca, M.
    Lerch, M. L. F.
    Matsufuji, N.
    Povoli, M.
    Summanwar, A.
    Kok, A.
    Jackson, M.
    Rosenfeld, A. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04):
  • [29] GEANT4 based simulation framework for particle therapy system
    Aso, Tsukasa
    Kimura, Akinori
    Kameoka, Satoru
    Murakami, Kouichi
    Sasaki, Takashi
    Yamashita, Tomohiro
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2564 - +
  • [30] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T