Screening for Carpal Tunnel Syndrome Using Sonography

被引:44
|
作者
Roll, Shawn C.
Evans, Kevin D. [1 ]
Li, Xiaobai [2 ]
Freimer, Miriam
Sommerich, Carolyn M. [3 ]
机构
[1] Ohio State Univ, Sch Allied Med Profess, Coll Med, Columbus, OH 43210 USA
[2] Ohio State Univ, Ctr Biostat, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Engn, Columbus, OH 43210 USA
关键词
diagnostics; electrodiagnostics; median mononeuropathy; musculoskeletal; CROSS-SECTIONAL AREA; MEDIAN NERVE; DIAGNOSTIC-VALUE; FUNCTIONAL STATUS; ULTRASONOGRAPHY; PREDICTORS; SEVERITY; ACCURACY; SYMPTOMS; RATIO;
D O I
10.7863/jum.2011.30.12.1657
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The use of sonography in musculoskeletal research and clinical applications is increasing; however, measurement techniques for diagnosing carpal tunnel syndrome with sonography continue to be inconsistent. Novel methods of measurement using internal comparisons to identify swelling of the median nerve require investigation and comparison to currently used techniques. Methods-The flattening ratio of the median nerve, bowing of the flexor retinaculum, and cross-sectional area of the median nerve were collected in the forearm, at the radiocarpal joint, and at the level of the pisiform in both symptomatic patients and asymptomatic control participants. Electrodiagnostic testing was completed in symptomatic patients as a diagnostic standard. Results-Median nerve measurements were collected from 166 wrists of symptomatic and asymptomatic participants. The flattening ratio did not show any correlation to electrodiagnostic testing and was identical between both symptomatic and asymptomatic participants. Moderate to strong correlations were noted between electrodiagnostic testing results and sonographic measurements of the cross-sectional area at the pisiform, retinacular bowing, and both the ratio and change of the cross-sectional area between the forearm and pisiform. The area under the curve was large for all receiver operating characteristic curves for each measurement (0.759-0.899), and sensitivity was high (80.4%-82.4%). Conclusions-Measurement of swelling through a ratio or absolute change had similar diagnostic accuracy as individual measurement of the cross-sectional area within the carpal tunnel. These measures may be useful for improving accuracy in more diverse clinical populations. Further refinement of protocols to identify the largest cross-sectional area within the carpal tunnel region and statistical methods to analyze clustered, multilevel outcome data are recommended to improve diagnostics.
引用
收藏
页码:1657 / 1667
页数:11
相关论文
共 50 条
  • [31] Gray scale and color Doppler sonography in the diagnosis of carpal tunnel syndrome
    Ghaffar, Maha K. Abdel
    El-Shinnawy, Maha A.
    Fawzy, Hazem
    Ibrahim, Soha Eldessouki
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2012, 43 (04): : 581 - 587
  • [32] Use of sonography in carpal tunnel syndrome surgery - A prospective study - Commentary
    Ducker, Thomas B.
    NEUROLOGIA MEDICO-CHIRURGICA, 2007, 47 (03) : 115 - 115
  • [33] Meta-Analysis on the Performance of Sonography for the Diagnosis of Carpal Tunnel Syndrome
    Descatha, Alexis
    Huard, Laure
    Aubert, Francois
    Barbato, Bruno
    Gorand, Olivier
    Chastang, Jean-Francois
    SEMINARS IN ARTHRITIS AND RHEUMATISM, 2012, 41 (06) : 914 - 922
  • [34] Combined Doppler and B-mode sonography in carpal tunnel syndrome
    Joy, Vijayan
    Therimadasamy, A. K.
    Chan, Y. C.
    Wilder-Smith, E. P.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2011, 308 (1-2) : 16 - 20
  • [35] CARPAL-TUNNEL SYNDROME - DIAGNOSIS WITH HIGH-RESOLUTION SONOGRAPHY
    BUCHBERGER, W
    JUDMAIER, W
    BIRBAMER, G
    LENER, M
    SCHMIDAUER, C
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (04) : 793 - 798
  • [36] Identification of Aberrant Muscle Bellies in the Carpal Tunnel Using Sonography
    Takata, Sandy C.
    Roll, Shawn C.
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2019, 35 (01) : 62 - 68
  • [37] SCREENING FOR CARPAL-TUNNEL SYNDROME IN PARAPLEGIC PATIENTS
    SIE, I
    CHANDLER, D
    GELLMAN, H
    PETRASEK, J
    ADKINS, R
    WATERS, R
    PHYSICAL THERAPY, 1988, 68 (05): : 865 - 865
  • [38] Ultrasound for carpal tunnel syndrome screening in manual laborers
    Cartwright, Michael S.
    Walker, Francis O.
    Blocker, Jill N.
    Schulz, Mark R.
    Arcury, Thomas A.
    Grzywacz, Joseph G.
    Mora, Dana
    Chen, Haiying
    Marin, Antonio J.
    Quandt, Sara A.
    MUSCLE & NERVE, 2013, 48 (01) : 127 - 131
  • [39] Screening for Carpal Tunnel Syndrome in the Workplace - The authors reply
    Nathan, PA
    Keniston, RC
    Meadows, KD
    Lockwood, RS
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1998, 40 (05) : 423 - 423
  • [40] Comparison of high-resolution sonography and electrophysiology in the diagnosis of carpal tunnel syndrome
    Kanikannan, Meena Angamuthu
    Boddu, Demudu Babu
    Umamahesh
    Sarva, Sailaja
    Durga, Padmaja
    Borgohain, Rupam
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2015, 18 (02) : 219 - 225