CARPAL-TUNNEL SYNDROME - DIAGNOSIS WITH HIGH-RESOLUTION SONOGRAPHY

被引:290
|
作者
BUCHBERGER, W
JUDMAIER, W
BIRBAMER, G
LENER, M
SCHMIDAUER, C
机构
[1] UNIV INNSBRUCK,INST MAGNET RESONANCE IMAGING & SPECT,A-6020 INNSBRUCK,AUSTRIA
[2] UNIV INNSBRUCK,DEPT NEUROL,A-6020 INNSBRUCK,AUSTRIA
关键词
D O I
10.2214/ajr.159.4.1529845
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Carpal tunnel syndrome is characterized by typical anatomic changes that can be shown with high-resolution sonography. To determine whether these findings are reliable and can be used to establish the diagnosis, sonograms of patients with the disease were compared with sonograms obtained in patients with normal wrists. Also compared were sonograms and MR images obtained in the patients with carpal tunnel syndrome. SUBJECTS AND METHODS. Twenty wrists in 18 consecutive patients with clinical symptoms of carpal tunnel syndrome and with abnormal nerve conduction studies were examined with real-time sonography and MR imaging. The sonograms and MR images were evaluated quantitatively by two unbiased observers with regard to the size and shape of the median nerve and the palmar bowing of the flexor retinaculum. A t test was used to compare these data with those from previous sonographic studies of 28 normal wrists. Correlation coefficients for the measurements obtained with sonography and with MR were calculated. The relative accuracies of different diagnostic criteria for the diagnosis of carpal tunnel syndrome were assessed by using receiver-operating-characteristic analytical techniques. RESULTS. Characteristic findings on both MR and CT scans of the 20 wrists with carpal tunnel syndrome included swelling of the median nerve in the proximal part of the carpal tunnel in 16 wrists, flattening of the median nerve in the distal part of the carpal tunnel in 13 wrists, and increased palmar bowing of the flexor retinaculum in nine wrists. Comparison with the data of 28 normal wrists proved that these findings were significant (p < .01 to p < .001). Receiver-operating-characteristic analysis showed that the discrimination between wrists in normal subjects and in patients with carpal tunnel syndrome achieved with each of the three diagnostic criteria was not significantly different. Measurements of the size and flattening of the median nerve obtained from sonograms were similar to those on MR images, whereas sonography was less accurate for measuring the palmar bowing of the flexor retinaculum. CONCLUSION. We conclude that the results of sonography are reliable, and that the diagnosis of carpal tunnel syndrome can be established on the basis of sonographic findings.
引用
收藏
页码:793 / 798
页数:6
相关论文
共 50 条
  • [1] Comparison of high-resolution sonography and electrophysiology in the diagnosis of carpal tunnel syndrome
    Kanikannan, Meena Angamuthu
    Boddu, Demudu Babu
    Umamahesh
    Sarva, Sailaja
    Durga, Padmaja
    Borgohain, Rupam
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2015, 18 (02) : 219 - 225
  • [2] High-resolution sonography versus EMG in the diagnosis of carpal tunnel syndrome
    Visser, L. H.
    Smidt, M. H.
    Lee, M. L.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2008, 79 (01): : 63 - 67
  • [3] THE VALUE OF HIGH-RESOLUTION SONOGRAPHY AND MR-IMAGING IN THE DIAGNOSIS AND FOLLOW-UP OF CARPAL-TUNNEL SYNDROME
    BUCHBERGER, W
    JUDMAIER, W
    BIRBAMER, G
    HASENOHRL, K
    SCHMIDAUER, C
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 159 (02): : 138 - 143
  • [4] High-resolution sonography and electrophysiology in carpal tunnel syndrome
    Meena, A. K.
    Babu, B. D.
    Sitajayalakshmi, S.
    Prasad, V. V. S. R. K.
    Borgohain, R.
    Maheshwar, U.
    JOURNAL OF NEUROLOGY, 2008, 255 : 94 - 94
  • [5] HIGH-RESOLUTION ULTRASONOGRAPHY OF THE CARPAL-TUNNEL
    BUCHBERGER, W
    SCHON, G
    STRASSER, K
    JUNGWIRTH, W
    JOURNAL OF ULTRASOUND IN MEDICINE, 1991, 10 (10) : 531 - 537
  • [6] Dynamic high-resolution sonography of the carpal tunnel
    Chen, PB
    Maklad, N
    Redwine, M
    Zelitt, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) : 533 - 537
  • [7] High resolution sonography in carpal tunnel syndrome
    `La Sapienza' Univ, Rome, Italy
    Ultrasound Med Biol, Suppl 1 (SPMO 8301):
  • [8] Importance of dynamic high-resolution sonography in diagnostic of the carpal tunnel syndrome
    Holc, I
    Pahor, A
    Krajnc, I
    AEurkoviae, B
    ANNALS OF THE RHEUMATIC DISEASES, 2003, 62 : 327 - 327
  • [9] DIAGNOSIS OF THE CARPAL-TUNNEL SYNDROME
    不详
    LANCET, 1985, 1 (8433): : 854 - 855
  • [10] THE DIAGNOSIS OF CARPAL-TUNNEL SYNDROME
    不详
    NEW ZEALAND MEDICAL JOURNAL, 1990, 103 (889) : 228 - 228