A comparative clinical and functional assessment of cortical button versus suture anchor in distal biceps brachii tendon repair

被引:15
|
作者
Reichert, Pawel [1 ]
Krolikowska, Aleksandra [2 ]
Kentel, Maciej [3 ]
Witkowski, Jaroslaw [1 ]
Gnus, Jan [1 ]
Satora, Wojciech [4 ]
Czamara, Andrzej [2 ]
机构
[1] Wroclaw Med Univ, Div Sports Med, Bartla 5, PL-50556 Wroclaw, Poland
[2] Coll Physiotherapy Wroclaw, Dept Physiotherapy, Wroclaw, Poland
[3] eMKaMED Med Ctr, Wroclaw, Poland
[4] St Lukes Hosp, Dept Trauma & Orthoped Surg, Bielsko Biala, Poland
关键词
RUPTURES; RELIABILITY; ENDOBUTTON; FIXATION; VALIDITY; STRENGTH;
D O I
10.1016/j.jos.2018.08.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The studies comparing the fixation methods being used for the ruptured distal biceps brachii tendon reinsertion show similar outcomes of cortical button and suture anchors usage, however, longer follow-up studies remain necessary. The goal of this study was to compare the clinical and functional three-year outcomes of the cortical button in contrast to the suture anchor fixation. Methods: A retrospective cohort study comprised of 28 males on average 3 years after surgical reinsertion of the distal biceps brachii tendon with the use of a cortical button (Group I, n = 11) or a suture anchor (Group II, n = 17). The outcomes assessed were range of elbow joint and forearm motion (ROM), arm circumferences, visual analogue scale (VAS), Mayo Elbow Performance Index (MEPI), Quick Disability of the Arm, Shoulder, and Hand (Quick DASH) and forearm flexor and supinator muscle torques measured under isometric and isokinetic conditions. Results: The comparison between the two studied groups revealed no statistically significant differences in ROM (p = 0.24-1.00), circumferences (p = 0.15-0.50), VAS (p = 0.71), MEPI (p = 0.23), Quick DASH (p = 0.61) or in the obtained muscle torque values (p = 0.07-1.00). However, differences in supination ROM between the surgical and non-surgical side were found in both groups (p = 0.01-0.02), and differences in pronation (p = 0.02) were found in Group II. The muscle torque values obtained in the surgical, dominant limb were lower than those in the nonsurgical, nondominant limb. Conclusion: The comprehensive comparison of three-year outcomes of cortical button versus suture anchor fixations did not favour one fixation method over the other, and the results justify the clinical usage of both methods. (C) 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [31] Intramedullary Cortical Button Repair for Distal Biceps Tendon Rupture: A Single-Center Experience
    Siebenlist, Sebastian
    Schmitt, Andreas
    Imhoff, Andreas B.
    Lenich, Andreas
    Sandmann, Gunther H.
    Braun, Karl F.
    Kirchhoff, Chlodwig
    Biberthaler, Peter
    Buchholz, Arne
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (05): : 418.e1 - 418.e7
  • [32] Repair of Distal Biceps Tendon Ruptures Using a Combined Anatomic Interference Screw and Cortical Button
    Mazzocca, Augustus D.
    Bicos, James
    Arciero, Robert A.
    Romeo, Anthony A.
    Cohen, Mark S.
    Nicholson, Gregory
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2005, 6 (02): : 108 - 115
  • [33] Low incidence of tendon rerupture after distal biceps repair by cortical button and interference screw
    Cusick, Michael C.
    Cottrell, Benjamin J.
    Cain, Richard A.
    Mighell, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (10) : 1532 - 1536
  • [34] Single-Incision Technique for Repair of Distal Biceps Tendon Avulsions With Intramedullary Cortical Button
    Camp, Christopher L.
    Voleti, Pramod B.
    Corpus, Keith T.
    Dines, Joshua S.
    ARTHROSCOPY TECHNIQUES, 2016, 5 (02): : E303 - E307
  • [35] Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques
    Citak, Mustafa
    Backhaus, Manuel
    Seybold, Dominik
    Suero, Eduardo M.
    Schildhauer, Thomas A.
    Roetman, Bernd
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (11) : 1936 - 1941
  • [36] Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques
    Mustafa Citak
    Manuel Backhaus
    Dominik Seybold
    Eduardo M. Suero
    Thomas A. Schildhauer
    Bernd Roetman
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1936 - 1941
  • [37] Distal rupture of the tendon of biceps brachii - Evaluation by MRI and the results of repair
    LeHuec, JC
    Moinard, M
    Liquois, F
    Zipoli, B
    Chauveaux, D
    LeRebeller, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05): : 767 - 770
  • [38] Bone tunnel and suture anchor fixation of distal biceps tendon ruptures
    Checo, Fernando J.
    Rodner, Craig M.
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2008, 16 (03): : 124 - 129
  • [39] Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair
    Mazzocca, Augustus D.
    Burton, Kevin J.
    Romeo, Anthony A.
    Santangelo, Stephen
    Adams, Douglas A.
    Arciero, Robert A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (02): : 252 - 258
  • [40] DISTAL BICEPS BRACHII TENDON AVULSION - A SIMPLIFIED METHOD OF OPERATIVE REPAIR
    LOUIS, DS
    HANKIN, FM
    ECKENRODE, JF
    SMITH, PA
    WOJTYS, EM
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (03): : 234 - 236