Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair

被引:190
|
作者
Mazzocca, Augustus D.
Burton, Kevin J.
Romeo, Anthony A.
Santangelo, Stephen
Adams, Douglas A.
Arciero, Robert A.
机构
[1] Univ Connecticut, Ctr Hlth, Dept Orthopaed Surg, Farmington, CT 06030 USA
[2] Orthopaed Assoc, Hartford, CT USA
[3] Rush Med Coll, Rush Presbyterian St Lukes Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2007年 / 35卷 / 02期
关键词
biceps tendon rupture; distal biceps tendon repair; biomechanical evaluation;
D O I
10.1177/0363546506294854
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Recent technical improvements have led the way to a resurgence of the single-incision approach for repair of distal biceps tendon injuries. There has been no biomechanical evaluation of all these techniques with comparison to the standard 2-incision bone tunnel technique. Hypothesis: There will be no difference under cyclic loading and ultimate failure between the 2-incision bone tunnel technique, suture anchor repair, interference screw, and EndoButton techniques for the repair of distal biceps tendon ruptures. Study Design: Controlled laboratory study. Methods: Sixty-three fresh-frozen cadaveric elbows were randomly assigned to 4 treatment groups (bone tunnel, EndoButton, suture anchor, interference screw). Cyclic loading was then performed from 0 degrees to 900 at 0.5 Hz for 3600 cycles with a 50-N load. A differential variable reductance transducer was placed between the radius and distal tendon to determine displacement. The construct was then pulled to failure at 120 mm/min. Results: A multiple analysis of variance revealed no statistically significant difference for displacement among the 4 repair techniques. Displacement using the bone tunnel was 3.55 mm, EncloButton was 3.42 mm, suture anchor was 2.33 mm, and interference screw was 2.15 mm. There was a statistically significant greater load to failure with EndoButton (440 N) than suture anchor (381 N), bone tunnel (310 N), or interference screw (232 N) (P < .001). Conclusion: The EndoButton technique had the highest load to failure. Clinical Relevance: These data demonstrate the EndoButton to be the strongest repair technique, with no failures during cycling at physiologic loads and with the largest load to failure. These findings are important in maximizing surgical results and stability and suggest that the construct can tolerate early postoperative active range of motion.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 50 条
  • [1] Distal biceps brachii tendon repair - An in vitro biomechanical study of tendon reattachment
    Berlet, GC
    Johnson, JA
    Milne, AD
    Patterson, SD
    King, GJW
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03): : 428 - 432
  • [2] RUPTURE OF THE DISTAL TENDON OF THE BICEPS BRACHII - A BIOMECHANICAL STUDY
    MORREY, BF
    ASKEW, LJ
    AN, KN
    DOBYNS, JH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (03): : 418 - 421
  • [3] Repair of distal biceps brachii tendon ruptures
    Bell, RH
    Wiley, WB
    Noble, JS
    Kuczynski, DJ
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2000, 9 (03) : 223 - 226
  • [4] REPAIR OF THE RUPTURED DISTAL TENDON OF THE BICEPS BRACHII
    WARE, HE
    NAIRN, DS
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (01): : 99 - 101
  • [5] Distal rupture of the tendon of biceps brachii - Evaluation by MRI and the results of repair
    LeHuec, JC
    Moinard, M
    Liquois, F
    Zipoli, B
    Chauveaux, D
    LeRebeller, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05): : 767 - 770
  • [6] Distal biceps tendon repair - A biomechanical comparison of intact tendon and 2 repair techniques
    Idler, Cary S.
    Montgomery, William H., III
    Lindsey, Derek P.
    Badua, Peter A.
    Wynne, Garnet F.
    Yerby, Scott A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (06): : 968 - 974
  • [7] Distal biceps brachii tendon repair: Suture anchor technique
    Burton, KJ
    Arciero, R
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2003, 11 (01) : 47 - 50
  • [8] Ultrasonography of Complications in Surgical Repair of the Distal Biceps Brachii Tendon
    Creteur, Viviane
    Madani, Afarine
    Sattari, Azadeh
    El Kazzi, Wissam
    Bianchi, Stefano
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (02) : 499 - 512
  • [9] Surgical repair of distal biceps tendon ruptures - A biomechanical comparison of two techniques
    Pereira, DS
    Kvitne, RS
    Liang, M
    Giacobetti, FB
    Ebramzadeh, E
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (03): : 432 - 436
  • [10] Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques
    Citak, Mustafa
    Backhaus, Manuel
    Seybold, Dominik
    Suero, Eduardo M.
    Schildhauer, Thomas A.
    Roetman, Bernd
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (11) : 1936 - 1941