Effect of the photon counting CT acquisition on beam hardening artifacts

被引:0
|
作者
Shikhaliev, PM [1 ]
机构
[1] Univ Calif Irvine, Irvine, CA 92717 USA
关键词
D O I
10.1118/1.1998253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Low noise performance of the photon counting x‐ray image acquisition applies also to CT when CT projections are acquired using a photon counting detector. However, the photon counting detector assigns a different weighting factor to the photons as compared to charge integrating, and the photon energy spectrum in the output of the detector is represented differently. This results in different magnitudes of the beam hardening artifacts in CT images acquired with photon counting and charge integrating detectors. Purpose of this work was to evaluate the effect of the photon counting on beam hardening artifacts in CT. Method and Materials: CT images of the head and breast equivalent phantoms including high and low contrast inserts were simulated at 120 kVp and 90 kVp x‐ray tube voltages. Photon counting, charge integrating and energy weighting detectors with photon energy weighting factors of 1, E and E−3, respectively, were considered. Magnitudes of the beam hardening artifacts were quantified and compared for these detectors. Results: Photon counting detector resulted in 4.5% increase of the magnitude of beam hardening artifacts from bone inserts as compared to charge integrating. The most optimal weighting of E−3, which provides the highest SNR, however, resulted in 18% increase in beam hardening artifacts from bone inserts. The magnitude of the “cupping” artifacts was higher by 2% and 5% for photon counting and energy weighting detectors, respectively, as compared to charge integrating. Only the photon counting provided accurate representation of the beam hardening effect due to its flat energy weighting. The charge integrating and energy weighting distorted the beam hardening effect because of energy dependent weighting factors. Conclusion: It is concluded that the low noise capabilities of the photon counting CT will not be compromised by the slight increase on appearance of the beam hardening artifacts. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
下载
收藏
页码:2057 / 2057
页数:1
相关论文
共 50 条
  • [1] Experimental study of beam hardening artifacts in photon counting breast computed tomography
    Bisogni, M. G.
    Del Guerra, A.
    Lanconelli, N.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    Panetta, D.
    Pani, R.
    Quattrocchi, M. G.
    Randaccio, P.
    Rosso, V.
    Russo, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 94 - 98
  • [2] Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT
    Haag, Florian
    Hokamp, Nils Grosse
    Overhoff, Daniel
    Dasegowda, Giridhar
    Kuru, Mustafa
    Noerenberg, Dominik
    Schoenberg, Stefan O.
    Kalra, Mannudeep K.
    Froelich, Matthias F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 175
  • [3] Iterative correction of beam hardening artifacts in CT
    Van Gompel, G.
    Van Slambrouck, K.
    Defrise, M.
    Batenburg, K. J.
    de Mey, J.
    Sijbers, J.
    Nuyts, J.
    MEDICAL PHYSICS, 2011, 38 : S36 - S49
  • [4] Reduction of metal artifacts: beam hardening and photon starvation effects
    Yadava, Girijesh K.
    Pal, Debashish
    Hsieh, Jiang
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [5] Ring-artifacts removal for photon-counting CT
    An, Kang
    Wang, Jue
    Zhou, Rifeng
    Liu, Fenglin
    Wu, Weiwen
    OPTICS EXPRESS, 2020, 28 (17) : 25180 - 25193
  • [6] Simultaneous correction of bone and contrast beam hardening artifacts in CT
    Ruth, C
    Joseph, PM
    RADIOLOGY, 1996, 201 : 1065 - 1065
  • [7] Reduction of beam-hardening artifacts in X-ray CT
    Menvielle, Nathalie
    Goussard, Yves
    Orban, Dominique
    Soulez, Gilles
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1865 - 1868
  • [8] THE EFFECT OF BEAM HARDENING ON CT VALUES
    WEIDENMAIER, W
    CHRIST, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1985, 143 (06): : 697 - 701
  • [9] Beam hardening and motion artifacts in cardiac CT: Evaluation and iterative correction method
    Shen, Zeyang
    Lee, Okkyun
    Taguchi, Katsuyuki
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [10] An experimental method to correct low-frequency concentric artifacts in photon counting CT
    Feng, Mang
    Ji, Xu
    Zhang, Ran
    Treb, Kevin
    Dingle, Aaron M.
    Li, Ke
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (17):