Retinal adaptive optics imaging with a pyramid wavefront sensor

被引:11
|
作者
Brunner, Elisabeth [1 ]
Shatokhina, Julia [2 ]
Shirazi, Muhammad Faizan [1 ]
Drexler, Wolfgang [1 ]
Leitgeb, Rainer [1 ]
Pollreisz, Andreas [3 ]
Hitzenberger, Christoph K.
Ramlau, Ronny [1 ,2 ,4 ]
Pircher, Michael [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Johann Radon Inst Computat & Appl Math, Altenbergerstr 69, A-4040 Linz, Austria
[3] Med Univ Vienna, Dept Ophthalmol & Optometry, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[4] Johannes Kepler Univ Linz, Ind Math Inst, Altenbergerstr 69, A-4040 Linz, Austria
来源
BIOMEDICAL OPTICS EXPRESS | 2021年 / 12卷 / 10期
基金
奥地利科学基金会; 欧盟地平线“2020”;
关键词
PUPIL;
D O I
10.1364/BOE.438915
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The pyramid wavefront sensor (P-WFS) has replaced the Shack-Har tmann (SH-) WFS as the sensor of choice for high-performance adaptive optics (AO) systems in astronomy. Many advantages of the P-WFS, such as its adjustable pupil sampling and superior sensitivity, are potentially of great benefit for AO-supported imaging in ophthalmology as well. However, so far no high quality ophthalmic AO imaging was achieved using this novel sensor. Usually, a P-WFS requires modulation and high precision optics that lead to high complexity and costs of the sensor. These factors limit the competitiveness of the P-WFS with respect to other WFS devices for AO correction in visual science. Here, we present a cost-effective realization of AO correction with a non-modulated P-WFS based on standard components and apply this technique to human retinal in vivo imaging using optical coherence tomography (OCT). P-WFS based high quality AO imaging was successfully performed in 5 healthy subjects and smallest retinal cells such as central foveal cone photoreceptors are visualized. The robustness and versatility of the sensor is demonstrated in the model eye under various conditions and in vivo by high-resolution imaging of other structures in the retina using standard and extended fields of view. As a quality benchmark, the performance of conventional SH-WFS based AO was used and successfully met. This work may trigger a paradigm shift with respect to the wavefront sensor of choice for AO in ophthalmic imaging.
引用
收藏
页码:5969 / 5990
页数:22
相关论文
共 50 条
  • [41] AO-OCT imaging of the retina with a pyramid wavefront sensor
    Brunner, Elisabeth
    Shatokhina, Julia
    Shirazi, Muhammad
    Drexler, Wolfgang
    Leitgeb, Rainer
    Hitzenberger, Christoph
    Ramlau, Ronny
    Pircher, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [42] Adaptive optics imaging of retinal vasculitis
    Errera, M. H.
    Paques, M.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [43] Retinal microvascular imaging with adaptive optics
    Kalitzeos, A.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [45] Retinal Vasculitis Imaging by Adaptive Optics
    Errera, Marie-Helene
    Coisy, Solene
    Fardeau, Christine
    Sahel, Jose-Alain
    Kallel, Sofiene
    Westcott, Mark
    Bodaghi, Bahram
    Paques, Michel
    OPHTHALMOLOGY, 2014, 121 (06) : 1311 - 1312
  • [46] Adaptive optics imaging of the retinal microvasculature
    Bedggood, Phillip
    Metha, Andrew
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (01) : 112 - 122
  • [47] Fourier wavefront reconstruction with a Pyramid wavefront sensor
    Bond, Charlotte Z.
    Correia, Carlos M.
    Sauvage, Jean-Francois
    El Hadi, Kacem
    Neichel, Benoit
    Fusco, Thierry
    ADAPTIVE OPTICS SYSTEMS VI, 2018, 10703
  • [48] Adaptive Optics Imaging in Retinal Vasculitis
    Mahendradas, Padmamalini
    Vala, Ruchi
    Kawali, Ankush
    Akkali, Mukund C.
    Shetty, Rohit
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2018, 26 (05) : 760 - 766
  • [49] Wavefront Sensing with Prisms for Astronomical Imaging with Adaptive Optics
    Engler, Byron
    Weddell, Steve
    Clare, Richard
    2017 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2017,
  • [50] First light on an adaptive optics system using a non-modulation pyramid wavefront sensor for a 1.8 m telescope
    王胜千
    魏凯
    郑文佳
    饶长辉
    Chinese Optics Letters, 2016, 14 (10) : 5 - 9