Retinal adaptive optics imaging with a pyramid wavefront sensor

被引:11
|
作者
Brunner, Elisabeth [1 ]
Shatokhina, Julia [2 ]
Shirazi, Muhammad Faizan [1 ]
Drexler, Wolfgang [1 ]
Leitgeb, Rainer [1 ]
Pollreisz, Andreas [3 ]
Hitzenberger, Christoph K.
Ramlau, Ronny [1 ,2 ,4 ]
Pircher, Michael [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Johann Radon Inst Computat & Appl Math, Altenbergerstr 69, A-4040 Linz, Austria
[3] Med Univ Vienna, Dept Ophthalmol & Optometry, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[4] Johannes Kepler Univ Linz, Ind Math Inst, Altenbergerstr 69, A-4040 Linz, Austria
来源
BIOMEDICAL OPTICS EXPRESS | 2021年 / 12卷 / 10期
基金
奥地利科学基金会; 欧盟地平线“2020”;
关键词
PUPIL;
D O I
10.1364/BOE.438915
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The pyramid wavefront sensor (P-WFS) has replaced the Shack-Har tmann (SH-) WFS as the sensor of choice for high-performance adaptive optics (AO) systems in astronomy. Many advantages of the P-WFS, such as its adjustable pupil sampling and superior sensitivity, are potentially of great benefit for AO-supported imaging in ophthalmology as well. However, so far no high quality ophthalmic AO imaging was achieved using this novel sensor. Usually, a P-WFS requires modulation and high precision optics that lead to high complexity and costs of the sensor. These factors limit the competitiveness of the P-WFS with respect to other WFS devices for AO correction in visual science. Here, we present a cost-effective realization of AO correction with a non-modulated P-WFS based on standard components and apply this technique to human retinal in vivo imaging using optical coherence tomography (OCT). P-WFS based high quality AO imaging was successfully performed in 5 healthy subjects and smallest retinal cells such as central foveal cone photoreceptors are visualized. The robustness and versatility of the sensor is demonstrated in the model eye under various conditions and in vivo by high-resolution imaging of other structures in the retina using standard and extended fields of view. As a quality benchmark, the performance of conventional SH-WFS based AO was used and successfully met. This work may trigger a paradigm shift with respect to the wavefront sensor of choice for AO in ophthalmic imaging.
引用
收藏
页码:5969 / 5990
页数:22
相关论文
共 50 条
  • [1] Adaptive optics with an infrared Pyramid wavefront sensor
    Bond, Charlotte Z.
    Wizinowich, Peter
    Chun, Mark
    Mawet, Dimitri
    Lilley, Scott
    Cetre, Sylvain
    Jovanovic, Nemanja
    Delorme, Jacques-Robert
    Wetherell, Edward
    Jacobson, Shane
    Lockhart, Charles
    Warmbier, Eric
    Wallace, James K.
    Hall, Donald N.
    Goebel, Sean
    Guyon, Olivier
    Plantet, Cedric
    Agapito, Guido
    Giordano, Christophe
    Esposito, Simone
    Femenia-Castella, Bruno
    ADAPTIVE OPTICS SYSTEMS VI, 2018, 10703
  • [2] Adaptive optics with an infrared pyramid wavefront sensor at Keck
    Bond, Charlotte Z.
    Cetre, Sylvain
    Lilley, Scott
    Wizinowich, Peter
    Mawet, Dimitri
    Chun, Mark
    Wetherell, Edward
    Jacobson, Shane
    Lockhart, Charles
    Warmbier, Eric
    Ragland, Sam
    Alvarez, Carlos
    Guyon, Olivier
    Goebel, Sean
    Delorme, Jacques-Robert
    Jovanovic, Nemanja
    Hall, Donald N.
    Wallace, James K.
    Taheri, Mojtaba
    Plantet, Cedric
    Chambouleyron, Vincent
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2020, 6 (03)
  • [3] Improvements on speed, stability and field of view in adaptive optics OCT for anterior retinal imaging using a pyramid wavefront sensor
    Brunner, Elisabeth
    Kunze, Laura
    Laidlaw, Victoria
    Jodlbauer, Daniel
    Drexler, Wolfgang
    Ramlau, Ronny
    Pollreisz, Andreas
    Pircher, Michael
    Biomedical Optics Express, 2024, 15 (10) : 6098 - 6116
  • [4] Adaptive optics for ophthalmic applications using a pyramid wavefront sensor
    Chamot, SR
    Dainty, C
    Esposito, S
    OPTICS EXPRESS, 2006, 14 (02): : 518 - 526
  • [5] Is wavefront coding an alternative to adaptive optics for retinal imaging?
    Acosta, E.
    Arines, J.
    Almaguer-Gomez, C.
    Bosch, S.
    Vallmitjana, S.
    2016 15TH WORKSHOP ON INFORMATION OPTICS (WIO), 2016,
  • [6] Progress on Wavefront Sensorless Adaptive Optics for Preclinical Retinal Imaging
    Jian, Yifan
    Wahl, Daniel
    Ju, Myeong Jin
    Zawadzki, Roberti
    Bonora, Stefano
    Sarunic, Marinko Venci
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [7] The pyramid wavefront sensor used in the closed-loop adaptive optics system
    Wang, Shengqian
    Wei, Kai
    Zheng, Wenjia
    Rao, Changhui
    ADAPTIVE OPTICS SYSTEMS V, 2016, 9909
  • [8] Pyramid and Hartmann-Shack wavefront sensor with artificial neural network for adaptive optics
    Diez, C. Alvarez
    Shao, F.
    Bille, J.
    JOURNAL OF MODERN OPTICS, 2008, 55 (4-5) : 683 - 689
  • [9] Performance simulation of the ERIS pyramid wavefront sensor module in the VLT adaptive optics facility
    Quiros-Pacheco, F.
    Agapito, G.
    Riccardi, A.
    Esposito, S.
    Le Louarn, M.
    Marchetti, E.
    ADAPTIVE OPTICS SYSTEMS III, 2012, 8447
  • [10] Wavefront sensor and wavefront corrector matching in adaptive optics
    Dubra, Alfredo
    OPTICS EXPRESS, 2007, 15 (06) : 2762 - 2769