Miniature Coil Array for Passive Magnetocardiography in Non-Shielded Environments

被引:14
|
作者
Zhu, Keren [1 ]
Shah, Adhvait M. [2 ]
Berkow, Jan [2 ]
Kiourti, Asimina [1 ]
机构
[1] Ohio State Univ, Dept Elect & Comp Engn, ElectroSci Lab, Columbus, OH 43221 USA
[2] Triton Syst Inc, Chelmsford, MA 01824 USA
关键词
Electrocardiography; Magnetic fields; Heart; Magnetic sensors; Sensor arrays; Magnetic noise; Bioelectromagnetics; Faraday's law; induction coils; magnetocardiography; MAGNETOENCEPHALOGRAPHY; ELECTROCARDIOGRAPHY; PERFORMANCE; OUTCOMES; ECG;
D O I
10.1109/JERM.2020.3019891
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Existing practices for monitoring heart activity rely heavily on electrocardiography (ECG) approaches, which suffer from low accuracy (as electric fields get impacted by biological tissues); extensive diagnostic times; and lack of comfort (as electrodes are in direct contact with the human body). Though magnetocardiography (MCG) provides more accurate and localized signals while also being non-contact, state-of-the-art equipment for capturing such weak magnetic fields (i.e., SQUIDs) requires extensive shielding and is very expensive. MCG sensing devices that do not require shielding have been reported, but they are sbulky, heavy, and cumbersome to use. In this work, we take a major step forward and propose a novel, miniature, and low-cost MCG sensor for operation in non-shielded environments that breaks the state-of-the-art boundaries in terms of size and weight. Our sensor relies on novel coil design principles and Digital Signal Processing (DSP) algorithms to achieve: (a) 4.67 times smaller diameter, (b) 4.5 times smaller height, and (c) at least 216 times lighter weight than previous passive implementations. In vitro measurements demonstrate that a 4-coil sensor array with 15 minutes of recoding time is sufficient to capture human MCG signals. Discussions indicate that higher number of coils and longer recording times can be employed to improve the signal clarity and fit diverse clinical needs. The proposed coil sensor array provides a convenient method to diagnose several cardiac conditions, such as myocardial ischemia, arrhythmia, right atrial hypertrophy, right ventricular hypertrophy, and the Brugada syndrome.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [41] Passive Vector Sensing for Non-Cooperative Emitter Localization in Indoor Environments
    Hall, Donald L.
    Narayanan, Ram M.
    Lenzing, Erik H.
    Jenkins, David M.
    ELECTRONICS, 2018, 7 (12)
  • [42] Bearing finding and array error correction in non-cooperative passive detection
    Liu, Zhiqiang
    Ma, Hongguang
    Wu, Xuemei
    Journal of Information and Computational Science, 2008, 5 (01): : 95 - 101
  • [43] Non-Contact Measurement of Electrolyte Solution With a Passive Coil Placed in Inductive Coupling System
    Xiong, Hao
    Dong, Yonggui
    IEEE SENSORS JOURNAL, 2016, 16 (11) : 4238 - 4245
  • [44] Nearly Non-Coupling Coil Array Allowing Many Independent Channels for Magnetic Communication
    Kim, Han-Joon
    Kim, Kyungtae
    Han, Sungmin
    Seo, Dong-Wook
    Choi, Ji-Woong
    IEEE ACCESS, 2018, 6 : 34190 - 34197
  • [45] A Miniature Four-Channel Ion Trap Array Based on Non-silicon MEMS Technology
    Zhang, Qi
    Lu, Xichi
    Chen, Ting
    Xiao, Yu
    Yao, Rujiao
    Yao, Jinyuan
    MICROMACHINES, 2021, 12 (07)
  • [46] Dynamic Model of Cable-Conduit Actuation for Interaction with Non-passive Environments
    Borowski, Andrew
    Metz, Alexander
    Sergi, Fabrizio
    2018 IEEE HAPTICS SYMPOSIUM (HAPTICS), 2018, : 40 - 45
  • [47] Passive location estimation using scatterer information for non-line-of-sight environments
    Yan, Jun
    Wang, Linru
    Wu, Lenan
    Journal of Southeast University (English Edition), 2010, 26 (04) : 518 - 522
  • [48] Design and analysis of a non-hysteretic passive magnetic linear bearing for cryogenic environments
    Diez-Jimenez, Efren
    Valiente-Blanco, Ignacio
    Castro-Fernandez, Victor
    Perez-Diaz, Jose L.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2014, 228 (10) : 1071 - 1079
  • [49] Mechanical Development of a Very Non-standard Patch Array Antenna for Extreme Environments
    Hughes, Richard
    Chamberlain, Neil
    Jakoboski, Julie
    Petkov, Mihail
    2012 IEEE AEROSPACE CONFERENCE, 2012,
  • [50] A non-linear controller for position and force control of robotic devices interacting with passive environments
    DasGupta, A
    PROCEEDINGS OF THE 36TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-5, 1997, : 1353 - 1354