Miniature Coil Array for Passive Magnetocardiography in Non-Shielded Environments

被引:14
|
作者
Zhu, Keren [1 ]
Shah, Adhvait M. [2 ]
Berkow, Jan [2 ]
Kiourti, Asimina [1 ]
机构
[1] Ohio State Univ, Dept Elect & Comp Engn, ElectroSci Lab, Columbus, OH 43221 USA
[2] Triton Syst Inc, Chelmsford, MA 01824 USA
关键词
Electrocardiography; Magnetic fields; Heart; Magnetic sensors; Sensor arrays; Magnetic noise; Bioelectromagnetics; Faraday's law; induction coils; magnetocardiography; MAGNETOENCEPHALOGRAPHY; ELECTROCARDIOGRAPHY; PERFORMANCE; OUTCOMES; ECG;
D O I
10.1109/JERM.2020.3019891
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Existing practices for monitoring heart activity rely heavily on electrocardiography (ECG) approaches, which suffer from low accuracy (as electric fields get impacted by biological tissues); extensive diagnostic times; and lack of comfort (as electrodes are in direct contact with the human body). Though magnetocardiography (MCG) provides more accurate and localized signals while also being non-contact, state-of-the-art equipment for capturing such weak magnetic fields (i.e., SQUIDs) requires extensive shielding and is very expensive. MCG sensing devices that do not require shielding have been reported, but they are sbulky, heavy, and cumbersome to use. In this work, we take a major step forward and propose a novel, miniature, and low-cost MCG sensor for operation in non-shielded environments that breaks the state-of-the-art boundaries in terms of size and weight. Our sensor relies on novel coil design principles and Digital Signal Processing (DSP) algorithms to achieve: (a) 4.67 times smaller diameter, (b) 4.5 times smaller height, and (c) at least 216 times lighter weight than previous passive implementations. In vitro measurements demonstrate that a 4-coil sensor array with 15 minutes of recoding time is sufficient to capture human MCG signals. Discussions indicate that higher number of coils and longer recording times can be employed to improve the signal clarity and fit diverse clinical needs. The proposed coil sensor array provides a convenient method to diagnose several cardiac conditions, such as myocardial ischemia, arrhythmia, right atrial hypertrophy, right ventricular hypertrophy, and the Brugada syndrome.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [31] A Novel Configurable Microwave Passive Component Based on Programmable Bridged-T Coil Array
    Lin, Yo-Shen
    Lu, Pei-Shan
    Wu, Yu-Cheng
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (06) : 3001 - 3014
  • [32] An Overlapping Array Coil for Eddy Current Non-destructive Evaluation
    Chen, Bo
    Tang, Dan
    Yan, Jiawen
    Liu, Zhiwei
    Zou, Hui
    Bao, Yang
    2021 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2021,
  • [33] Improvement and application of miniature Hopkinson bar device based on series-parallel coil array electromagnetic launch
    Cai, Su
    Wu, Dongliang
    Zhou, Jiangfan
    Zhang, Chitao
    Liu, Zhanwei
    Liu, Sheng
    MEASUREMENT, 2021, 186
  • [34] Passive Target Localization in Non-Line-of-Sight Environments
    Guo, Kaichen
    Shi, Zheng
    Ma, Shaodan
    2016 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS (ICCS), 2016,
  • [35] SYNTHESIS OF THE PASSIVE DIPOLES ARRAY WITH THE NON-SIDELOBES PATTERN
    MIKHAILOV, MY
    CHAPLIN, AF
    RADIOTEKHNIKA I ELEKTRONIKA, 1985, 30 (02): : 392 - 393
  • [36] Vertical Array Passive Geo-Acoustic Inversion in Range-Dependent Environments
    Leclerc, James H.
    DelBalzo, Donald R.
    Pflug, Lisa A.
    OCEANS 2009, VOLS 1-3, 2009, : 1628 - 1634
  • [37] Passive Steering of Miniature Walking Robot using the Non-Uniformity of Robot Structure
    Qu, Jinhong
    Teeple, Clark B.
    Zhang, Buyi
    Oldham, Kenn R.
    2018 INTERNATIONAL CONFERENCE ON MANIPULATION, AUTOMATION AND ROBOTICS AT SMALL SCALES (MARSS), 2018,
  • [38] Array Antenna Design for Passive Coherent Location Systems with Non-Uniform Array Configurations
    Jang, Doyoung
    Hur, Jun
    Shim, Hongsuk
    Park, Junsik
    Cho, Chihyun
    Choo, Hosung
    JOURNAL OF ELECTROMAGNETIC ENGINEERING AND SCIENCE, 2020, 20 (03): : 176 - 182
  • [39] An integrated system for non-destructive detection of shielded nuclear material using multiple modes of passive detection
    van der Ende, B. M.
    Horn, D.
    Kamaev, O.
    Li, L.
    Rand, E. T.
    Thompson, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1033
  • [40] A cross-river antenna array for the detection of miniature passive integrated transponder tags in deep, fast flowing rivers
    Ibbotson, AT
    Beaumont, WRC
    Collinson, D
    Wilkinson, A
    Pinder, AC
    JOURNAL OF FISH BIOLOGY, 2004, 65 (05) : 1441 - 1443