Dosimetric impact of tantalum markers used in the treatment of uveal melanoma with proton beam therapy

被引:57
|
作者
Newhauser, Wayne D.
Koch, Nicholas C.
Fontenot, Jonas D.
Rosenthal, Stanley J.
Gombos, Dan S.
Fitzek, Markus M.
Mohan, Radhe
机构
[1] Univ Texas, MD Anderson Canc Ctr, Unit 94, Dept Head & Neck Surg,Sect Ophthalmol, Houston, TX 77030 USA
[2] Univ Texas, Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
[4] Midwest Proton Radiotherapy Inst, Bloomington, IN 47408 USA
[5] Indiana Univ, Sch Med, Indianapolis, IN 46202 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 13期
关键词
D O I
10.1088/0031-9155/52/13/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Metallic fiducial markers are frequently implanted in patients prior to external-beam radiation therapy to facilitate tumor localization. There is little information in the literature, however, about the perturbations in proton absorbed-dose distribution these objects cause. The aim of this study was to assess the dosimetric impact of perturbations caused by 2.5 mm diameter by 0.2 mm thick tantalum fiducial markers when used in proton therapy for treating uveal melanoma. Absorbed dose perturbations were measured using radiochromic film and confirmed by Monte Carlo simulations of the experiment. Additional Monte Carlo simulations were performed to study the effects of range modulation and fiducial placement location on the magnitude of the dose shadow for a representative uveal melanoma treatment. The simulations revealed that the fiducials caused perturbations in the absorbed-dose distribution, including absorbed-dose shadows of 22% to 82% in a typical proton beam for treating uveal melanoma, depending on the marker depth and orientation. The clinical implication of this study is that implanted fiducials may, in certain circumstances, cause dose shadows that could lower the tumor dose and theoretically compromise local tumor control. To avoid this situation, fiducials should be positioned laterally or distally with respect to the target volume.
引用
收藏
页码:3979 / 3990
页数:12
相关论文
共 50 条
  • [42] Gantry-based pencil beam scanning proton therapy for uveal melanoma: IMPT versus proton arc therapy
    Qi, Hang
    Hu, Lei
    Huang, Sheng
    Lee, Yen-Po
    Yu, Francis
    Chen, Qing
    Yang, Yunjie
    Kang, Minglei
    Zhai, Huifang
    Vermeulen, Milo
    Shim, Andy
    Park, Peter
    Ding, Xuanfeng
    Zhou, Jun
    Abramson, David H.
    Francis, Jasmine H.
    Simone, Charles B.
    Barker, Christopher A.
    Lin, Haibo
    RADIATION ONCOLOGY, 2025, 20 (01)
  • [43] PROTON-BEAM THERAPY OF UVEAL MELANOMAS
    GRAGOUDAS, ES
    ARCHIVES OF OPHTHALMOLOGY, 1986, 104 (03) : 349 - 351
  • [44] Baerveldt shunts in the treatment of glaucoma secondary to anterior uveal melanoma and proton beam radiotherapy
    Sharkawi, Eamon
    Oleszczuk, Justyna D.
    Bergin, Ciara
    Zografos, Leonidas
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (08) : 1104 - 1107
  • [45] Proton beam radiotherapy for uveal melanoma: Results of curie institut-orsay proton therapy center (ICPO)
    Dendale, Remi
    Lumbroso-Le Rouic, Livia
    Noel, Georges
    Feuvret, Loic
    Levy, Christine
    Delacroix, Sabine
    Meyer, Anne
    Nauraye, Catherine
    Mazal, Alejandro
    Mammar, Hamid
    Garcia, Paul
    D'Hermies, Francois
    Frau, Eric
    Plancher, Corine
    Asselain, Bernard
    Schlienger, Pierre
    Mazeron, Jean Jacques
    Desjardins, Laurence
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03): : 780 - 787
  • [46] Ocular proton therapy, pencil beam scanning high energy proton therapy or stereotactic radiotherapy for uveal melanoma; an in silico study
    Peyrichon, M. L.
    Vidal, M.
    Barnel, C.
    Sauerwein, W.
    Carnicer, A.
    Angellier, G.
    Mathis, T. M.
    Mishra, K. K.
    Thariat, J.
    Herault, J.
    Herault, J.
    CANCER RADIOTHERAPIE, 2022, 26 (08): : 1027 - 1033
  • [47] Preliminary Dosimetric Study of Proton Minibeam Radiation Therapy for the Treatment of Choroidal Melanoma
    Kim, Myeongsoo
    Kim, Sang Soo
    Kim, Haksoo
    Moon, Sung Ho
    Lim, Young Kyung
    Hwang, Ui-Jung
    Choi, Sang Hyoun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (05) : 447 - 451
  • [48] Preliminary Dosimetric Study of Proton Minibeam Radiation Therapy for the Treatment of Choroidal Melanoma
    Myeongsoo Kim
    Sang Soo Kim
    Haksoo Kim
    Sung Ho Moon
    Young Kyung Lim
    Ui-Jung Hwang
    Sang Hyoun Choi
    Journal of the Korean Physical Society, 2020, 77 : 447 - 451
  • [49] Cyclotrons in cancerology: proton therapy applied to uveal melanoma
    Allouch, H
    PRESSE MEDICALE, 2000, 29 (15): : 841 - +
  • [50] PROTON BEAM RADIOTHERAPY FOR UVEAL MELANOMA: RESULTS IN OUR CENTER
    Mammar, H.
    Caujolle, J. P.
    Herault, J.
    Angellier, G.
    Mandrillon, P.
    Trimaud, R.
    Gerard, J. P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S227 - S227